16 Jul 2008: Procedure: Removing and installing the COM board on Magnus 400 configurations with image CD 1.14 More...
This procedure describes how to remove and install the COM board on Magnus 400 configurations with image CD 1.14.
Go to Parts replacement on the Procedures
page.
TechPlanet DVD Version 7 N.2—10 Jul 2008
30 Jun 2008: Troubleshooting: 0.15 plates intermittently load crookedly on Magnus 400 family semi-automatic platesetters More...
Incorrect plate loading parameters prevent 0.15
plates from reaching the registration pins and loading properly onto the
drum.
Go to loading on the Troubleshooting
page.
25 Jun 2008: Troubleshooting: Paper bin task fails on platesetters with Magnus 400 Controller 1.02.392 or 1.04.393 More...
When using wide plates, the paper
bin task fails because the tweezers fail to pick up the plates.
Go to paper disposal on the Troubleshooting page.
17 Jun 2008: Troubleshooting: Status messages reappear in Service Shell on Magnus 400 Quantum More...
When status
messages continuously reappear in Service Shell, type a sequence of commands
to correct the problem.
Go to error/system messsages on the Troubleshooting page.
15 Jun 2008: Troubleshooting: Get fails when using smart edge detection on Magnus 400 family platesetters with Magnus 400 Controller 1.01.391 More...
Verify that the correct smart edge detection board is installed, start
the Magnus 400 Controller 1.01.391 with Update 3 software, and configure
the Communicator for SED Card parameter for COM6.
Go to edge detection on the Troubleshooting page.
15 Jun 2008: Troubleshooting: Banding might occur when using Agfa Amigo plates and thermal 2 head on Magnus 400 Quantum/Magnus 400 II Quantum platesetters More...
When white
lines (banding) appear on Agfa Amigo plates with AM or FM screening that
are imaged at the specified power and drum speed, reduce the laser power and drum speed to maintain the 240 mJ/cm2 exposure.
Go to imaging on the Troubleshooting page.
03 Jun 2008: Troubleshooting: Activating Windows 2000 cache memory on Magnus 400 and Magnus 400 II family platesetters More...
If the Write cache enabled check box is not selected, the
cache memory is not saved.
Go to Performance on the Troubleshooting page.
28 May 2008: FCO 512-00492A: Improved power distribution board More...
FCO 512-00492A installs the improved power distribution board (PDB) to prevent board burn-out due to
continuous drum vacuum pump operation.
Go to the FCOs page.
04 May 2008: Procedure: Removing and installing the power distribution board More...
This procedure describes how to remove and install the power distribution board (PDB).
Go to Parts replacement on the Procedures page.
30 Apr 2008: Procedure: Removing and installing the leadscrew More...
This procedure describes how to remove and install the leadscrew.
Go to Parts replacement on the Procedures page.
28 Apr 2008: Troubleshooting: Magnus 400 Controller communication with MCE is slow More...
On Magnus 400 family configurations with disc image version 1.14, the Magnus
400 Controller software is slow to establish communication with the MCE device,
and once established, the Unauthenticated User icon appears in the Quick Launch
tray.
Go to Connectivity on the Troubleshooting page.
03 Apr 2008: Technical bulletin: Optimizing the Width Start Image Area According to Plate Size on Magnus 400 and Magnus 400 II Family Platesetters More...
The difference in distance between the inner registration pin and the outer registration pin is 0.5 mm.
To ensure that your plate is properly aligned for plate exposure, adjust the Width Start Image Area parameter.
Go to Technical bulletins on the Reference page.
01 Apr 2008: Procedure: Removing and installing the drum motor More...
If the drum motor fails to rotate the drum, rotates the drum in the wrong direction, or is excessively noisy, you might need to replace the drum motor.
This procedure describes how to remove and install the drum motor.
Go to Parts replacement on the Procedures page.
28 Feb 2008: Magnus 400 Component Finder More...
Two versions of the Magnus 400 Component Finder are available on TechPlanet: a web-based version, which is a browser enabled, searchable database
containing all the Magnus 400 components, and a downloadable version.
Go to Tools on the Parts/tools page, or
Component finder on the Reference page.
TechPlanet DVD Version 7 N.1—15 Feb 2008
11 Feb 2008: Troubleshooting: Intermittent stepper motor failure More...
When the ampere values of the black stepper motor are not calibrated correctly
on Magnus 400 and Magnus 400 Quantum platesetters, the stepper
motor fails intermittently.
Go to carriage on the Troubleshooting page.
07 Feb 2008: Maintenance kit part number updated More...
The part number for the Basic PM Kit for Quantum configurations with MCU has been promoted from 518-01320A to 518-01320B.
In addition to the Lotem Quantum with MCU configuration, the updated part number is also relevant to the Magnus 400 Quantum with MCU and Magnus 400 II Quantum with MCU II configurations.
Go to the Parts/tools page.
01 Jan 2008: Procedure: Using the Magnus Output Devices Installation Report Tool More...
This procedure describes how to use the Magnus Output Devices Installation Report Tool.
The tool enables field engineers to provide installation feedback to Kodak.
After every installation, open the Magnus Output Devices Installation Report Tool and submit the report.
Go to the Installation
page.
25 Dec 2007: Procedure: Installing a status indicator on a Magnus 400 Quantum platesetter with MCU More...
Install the optional status indicator to view the real-time status of the platesetter duirng operation.
Go to the Procedures page.
17 Dec 2007: Warning: Magnus 400 Quantum platestters do not work with Magnus 400 Controller 1.04.393 More...
Until the Magnus 400 Controller 1.05.394 software is released, use only the Magnus 400
Controller 1.02.392 software with the platesetter. Magnus 400 Controller 1.04.393 software has problems with cassette functionality.
14 Nov 2007: Exposure head request (EHR) form More...
Each time that you replace a thermal imaging head, you must fill out the Exposure head request (EHR) form and notify all
members on the #CEM-EH Request list.
For more information about returning thermal heads, see Replacing
a thermal head.
Go to the Parts/tools page.
12 Nov 2007: FCO 512-00460A: One-piece load roller More...
FCO 512-00460A installs the improved one-piece load roller to eliminate roller marks on plates
during the loading process.
Go to the FCOs page.
03 Nov 2007: Procedure: Adjusting the drum vibration sensors More...
When the drum stops frequently rotating and vibration error messages appear, you need to
adjust the position of the drum vibration sensors.
Go to the Procedures page.
TechPlanet DVD Version 6 N.3—01 Nov 2007
18 Oct 2007: Reference: Lenticular printing reference guide More...
Enhance your platesetter output with lenticular printing.
Go to the Reference page.
18 Oct 2007: Procedure: Setting up the Magnus 400 Quantum for lenticular printing More...
Learn how to set up your Magnus 400 Quantum platesetter for lenticular printing.
Go to the Procedures page.
10 Sep 2007: FCO 512-00450A: Kit FCO for Magnus 400 Conveyor More...
FCO 512-00450A installs an improved middle support guide and front cover bracket on the plate conveyor to
accommodate smaller plate sizes.
Go to the FCOs page.
19 Aug 2007: New features and parts on Magnus 400: Sensor wiring More...
The sensor wiring, which performs the same function as the upper and
lower enable detectors, enables the system to accurately locate the
drum position so that the grippers open at the correct loading and unloading
position.
Go to New features/parts on the Reference
page.
04 Jul 2007: Troubleshooting: UDRC hose collides with rotating drum on Magnus 400 Quantum More...
During plate operation, the edge
of the spoiler bends.
Go to other
on the Troubleshooting
page.
24 Jun 2007: Troubleshooting: Plate skews during drum loading More...
During the plate-picking stage of the loading sequence, the vertical orientation
of one of the suction cups is skewed because a
suction cup leg bearing is loosely seated in the XY loading assembly bar.
Go to Loading
or Plates
on the Troubleshooting
page.
19 Jun 2007: Troubleshooting: MCE connection fails on Dell PE2900 workflow workstations More...
To avoid MCE
connectivity problems on Magnus 400 Quantum platesetters, replace the SCSI board.
Go to connectivity on the Troubleshooting
page.
12 Jun 2007: Troubleshooting: "Punch Format is not available" appears on Magnus 400 Quantum More...
When you expose a 459 x 525 mm (18.07 x 20.67 in.) plate on a Magnus 400 Quantum platesetter with Kodak Brisque software, "Punch Format is not available" appears and the punch fails. Find this item under error/system messages on the Troubleshooting page.
TechPlanet DVD Version 6 N.2—01 Jun 2007
16 Apr 2007: FCO 512-00422A Installing Creo Feature Licensing Server More...
FCO 512-00422A installs the Creo Feature Licensing Server on Magnus 400 and Magnus 400 Quantum platesetters. Find this item on the FCOs page.
10 Apr 2007: Saving and restoring NVS parameters on a Magnus 400 Quantum platesetter More...
Before you upgrade any software on the platesetter, or in case a cold-start installation is required, save the nonvolatile storage (NVS) parameters, as described in Saving and restoring NVS parameters on a Magnus 400 Quantum platesetter. Find the procedure under Backup on the Procedures page.
27 Mar 2007: D-box Revision C for Magnus 400 More...
The new D-box Revision C replaces D-box Rev B. With D-box Rev C, you no longer need to use voltage selector keys or make power adjustments. For more information, see Ordering information on the Parts/tools page.
27 Mar 2007: Configuring punches on Magnus 400 More...
After you install punches on the platesetter, you need to configure them either from the registry or with the Kodak Magnus 400 Controller software. Find this item under Configuration on the Procedures page.
20 Mar 2007: Creo Feature Licensing Server for Magnus 400 More...
The Creo Feature Licensing (CFL) Server is an integrated feature license management system that provides feature control management for multiple applications. Use the CLF server together with Service Shell 2.6 SP2. Find these items under Creo Feature Licensing Server on the Downloads page.
18 Mar 2007: Installing the center punch on Magnus 400 and Lotem 400 More...
The image between the plates will not be correctly registered if the plate height is not exactly the size it is supposed to be when using the image-to-edge edge detection system. To avoid this problem, cancel edge detection and perform image exposure according to image-to-punch, as described in “ Installing the center punch on Lotem 400 and Magnus 400 ”. Find this procedure under Parts replacement on the Procedures page.
12 Mar 2007: Registration pin configurations on Magnus 400 More...
The Kodak Magnus 400 platesetter supports three registration pin configurations. Find the correct registration pin configuration for your platesetter under Technical bulletins on the Reference page.
TechPlanet DVD Version 6 N.1—22 Feb 2007
19 Feb 2007: Replacing the drum encoder on Magnus 400 More...
When the drum encoder cannot identify the drum position or sends the drum motor to the wrong drum position, you need to replace the drum encoder. Find this item under Parts replacement on the Procedures page.
15 Feb 2007: Troubleshooting: “Machine dongle not detected” on Magnus 400 Quantum and Lotem 400 Quantum More...
If your platesetter has a problem with the dongle, you need to reset the platesetter. Find this item under error-system messages on the Troubleshooting page.
05 Feb 2007: Replacing a thermal 2 head on a Magnus 400 Quantum platesetter More...
The procedure, Replacing TH2 on Magnus 400 Quantum, describes how to install a new thermal 2 head on a Magnus 400 Quantum platesetter. Find this item under Parts replacement on the Procedures page.