| FCO | Component/Activity | Date | Description | Priority | Time Required (hours) |
|---|---|---|---|---|---|
| L-box, mother and daughter board replacement |
28.02.02 |
Prevent shorts in L-Box by preventing condensation. |
Next Visit |
3-6 |
|
| NUC board comp level P installation |
07.01.02 |
Update all boards with boards that were tested with MCU (com 6) to support Lotem with Local 3. |
Next Failure |
0.5 |
|
FCO |
Component/Activity |
Date |
Description |
Priority |
Time Required (hours) |
|---|---|---|---|---|---|
| Vibration detectors, relocation and replacement |
05.05.02 |
Improve reliability of vibration sensors. |
Next Failure |
2 |
|
| Plate rollers, anti-scratch kit, drill hole in mainframe |
12.11.01 |
Enable replacement of plate rollers with anti-scratch rollers. |
Next Failure |
2 |
|
| Unload rollers, pressure/vacuum assembly replacement |
13.05.01 |
Enable adjusting air pressure for unload rollers; prevent pressure marks; enable all pressure and vacuum units to be installed on one bracket and add air pressure valve. |
Next Failure |
1.5 |
|
| Encoder connector replacement |
20.08.00 |
Isolating the internal wires of drum encoder connector. |
Next Failure |
N/A |
|
| V block bracket, double oil kit installation |
02.12.99 |
Adding an oil kit to the optic head carriage decreases friction between the carriage surface and the V block. It also cleans the V block surface. |
Next Failure |
N/A |
|
| Fly off assembly replacement |
24.11.99 |
Replace the fly off assembly unit to position the fly off sensor in a fixed position in relation to the drum. |
Next Failure |
N/A |
|
| V block bracket, oil kit installation |
10.03.99 |
Add an oil kit to decrease the friction of the carriage surface to the V block. |
Next Failure |
N/A |
|
| Roller assembly, 0.2 mm installation |
16.11.98 |
Adding assembly rollers to enable loading 0.2 mm plate. |
Next Failure |
N/A |
|
| Fly off sensor replacement |
28.10.98 |
Replace the fly off sensor with a more reliable design. |
Next Failure |
N/A |
|
| Head gripper replacement |
22.10.98 |
Replacing the Head Gripper Assembly with new type which is stronger |
Next Failure |
N/A |
|
FCO |
Component/Activity |
Date |
Description |
Priority |
Time Required (hours) |
|---|---|---|---|---|---|
| Light detector, dust seal installation |
11.04.02 |
Eliminate damage to light detector and its malfunction by preventing dust from entering it. |
Next Failure |
1 |
|
| Optic lens, air filter installation |
27.01.99 |
To provide clean and dry air to the optic lens system, add a new filter. |
Next Failure |
N/A |
|
FCO |
Component/Activity |
Date |
Description |
Priority |
Time Required (hours) |
|---|---|---|---|---|---|
| Paper/metal detector, optical, replacement |
01.02.01 |
Increase difference in readings between plate and paper and sensitivity range for adjustment by replacing 90 degree optical paper-plate detector bracket with tilted one. |
Next Visit |
1.5 |
|
| X motor, replacement |
07.03.00 |
Replace X motor assembly to improve motor life expectancy and prevent breakage of the pin in the shaft. |
Next Failure |
N/A |
|
| Paper/metal detector, optical, replacement |
21.02.00 |
Replace the existing detector to improve reliability and prevent denting on the plate. |
Next Failure |
N/A |
|
| Cassette, magnetic sensor installation |
18.10.99 |
All loading cassettes must be updated when a magnetic sensor - loading cassette is installed. |
Next Failure |
N/A |
|
| Disposal door locker replacement |
29.03.99 |
Replace the disposal door locker with a new locker to tighten the door to the main frame. |
Next Failure |
N/A |
|
| Bar flag and housing replacement |
10.03.99 |
Replace the present bar flag and housing with the new type of each. |
Next Failure |
N/A |
|
| Cassette, paper air out - insert air injectors |
25.02.99 |
Insert two compressed air injectors and connect two air hoses from manifold, if there is a problem separating paper from plate (Horsell or Fuji) when plate is already out of cassette-due to static electricity. |
Next Failure |
N/A |
|
| Cassette, metal nipples replacement |
16.11.98 |
Replacing the air pressure angled plastic nipples with metal nipples. |
Next Failure |
N/A |
|
| Paper disposal detector installation |
16.11.98 |
Add a paper detector to indicate paper inside the paper disposal box. |
Next Failure |
N/A |
|
FCO |
Component/Activity |
Date |
Description |
Priority |
Time Required (hours) |
|---|---|---|---|---|---|
| Remote support installation |
30.10.01
|
Enable dialing into a Lotem 800 anywhere in world to take control of it and run diagnostics to solve problems. |
Next Visit |
1 |
|
| Version 3.20.01 notice (release notes separate) |
25.03.01 |
Support machines with Local 3 board, fix bugs and improve loading sequence. |
Next Failure |
20 mins |
|
| Upgrade to version 2.10.06 |
25.01.99 |
The primary targets of this version are improved reliability and a throughput of 10 plates per hour. |
Next Failure |
N/A |
|
FCO |
Component/Activity |
Date |
Description |
Priority |
Time Required (hours) |
|---|---|---|---|---|---|
| Door, rear, piston bracket replacement |
05.01.99 |
Replace the rear door piston brackets to ensure that rear cover stays up when opened. |
Next Failure |