Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Magnus 400E Home Page

For product overview, status, and specifications, see the Overview page.

Product Support News Expand/collapse all news items


16 Jul 2008: Procedure: Removing and installing the COM board on Magnus 400 configurations with image CD 1.14 More...

This procedure describes how to remove and install the COM board on Magnus 400 configurations with image CD 1.14.
Go to Parts replacement on the Procedures page.

TechPlanet DVD Version 7 N.2—10 Jul 2008

30 Jun 2008: Troubleshooting: 0.15 plates intermittently load crookedly on Magnus 400 family semi-automatic platesetters More...

Incorrect plate loading parameters prevent 0.15 plates from reaching the registration pins and loading properly onto the drum.
Go to Loading on the Troubleshooting page.

25 Jun 2008: Troubleshooting: Hasp (F-speed key) error on Magnus 400 family platesetters More...

When starting the Magnus 400 Controller software, hasp error messages appear.
Go to Startup on the Troubleshooting page.

25 Jun 2008: Troubleshooting: Paper bin task fails on platesetters with Magnus 400 Controller 1.02.392 or 1.04.393 More...

When using wide plates, the paper bin task fails because the tweezers fail to pick up the plates.
Go to Paper disposal on the Troubleshooting page.

15 Jun 2008: Troubleshooting: Get fails when using smart edge detection on Magnus 400 family platesetters with Magnus 400 Controller 1.01.391 More...

Verify that the correct smart edge detection board is installed, start the Magnus 400 Controller 1.01.391 with Update 3 software, and configure the Communicator for SED Card parameter for COM6.
Go to Edge detection on the Troubleshooting page.

11 Jun 2008: Updated: Calibration test procedures and overview More...

The Lotem 400 FH, Magnus 400 LDA, and Magnus 400 II LDA calibration test procedures have been updated and are available for reference purposes. A short overview, including anti-collision guidelines, is also available.
Go to Calibration tests under Calibration on the Procedures page.

03 Jun 2008: Troubleshooting: Activating Windows 2000 cache memory on Magnus 400 and Magnus 400 II family platesetters More...

If the Write cache enabled check box is not selected, the cache memory is not saved.
Go to Performance on the Troubleshooting page.

28 May 2008: FCO 512-00492A: Improved power distribution board More...

FCO 512-00492A installs the improved power distribution board (PDB) to prevent board burn-out due to continuous drum vacuum pump operation.
Go to the FCOs page.

04 May 2008: Troubleshooting: Laser diode failure on Magnus 400 More...

If a laser diode failure occurs on a Magnus 400 platesetter, run diagnostics before you calibrate or splice any diodes.
Go to Exposing on the Troubleshooting page.

01 May 2008: Procedure: Removing and installing the power distribution board More...

This procedure describes how to remove and install the power distribution board (PDB).
Go to Parts replacement on the Procedures page.

30 Apr 2008: Procedure: Removing and installing the leadscrew More...

This procedure describes how to remove and install the leadscrew.
Go to Parts replacement on the Procedures page.

30 Apr 2008: Procedure: Upgrading a Magnus 400 E/Magnus 400 II E platesetter to a Magnus 400 S/Magnus 400 II S platesetter More...

This procedure describes how to upgrade from a Magnus 400 E/Magnus 400 II E functionality-limited configuration to a Magnus 400 S/Magnus 400 II S speed configuration with greater functionality.
Go to Magnus 400 E Specific on the Procedures page.

28 Apr 2008: Troubleshooting: Magnus 400 Controller communication with MCE is slow More...

On Magnus 400 family configurations with disc image version 1.14, the Magnus 400 Controller software is slow to establish communication with the MCE device, and once established, the Unauthenticated User icon appears in the Quick Launch tray.
Go to Connectivity on the Troubleshooting page.

03 Apr 2008: Technical bulletin: Optimizing the Width Start Image Area According to Plate Size on Magnus 400 and Magnus 400 II Family Platesetters More...

The difference in distance between the inner registration pin and the outer registration pin is 0.5 mm. To ensure that your plate is properly aligned for plate exposure, adjust the Width Start Image Area parameter.
Go to Technical bulletins on the Reference page.

01 Apr 2008: Procedure: Removing and installing the drum motor More...

If the drum motor fails to rotate the drum, rotates the drum in the wrong direction, or is excessively noisy, you might need to replace the drum motor. This procedure describes how to remove and install the drum motor.
Go to Parts replacement on the Procedures page.

28 Feb 2008: Magnus 400 Component Finder More...

Two versions of the Magnus 400 Component Finder are available on TechPlanet: a web-based version, which is a browser enabled, searchable database containing all the Magnus 400 components, and a downloadable version.
Go to Tools on the Parts/tools page, or Component finder on the Reference page.

26 Feb 2008: LDA drivers for Magnus 400 family and Magnus 400 II family platesetters More...

Two LDA drivers are available for Magnus 400 and Magnus 400 II platesetter configurations.
Go to Technical bulletins on the Reference page.

TechPlanet DVD Version 7 N.1—15 Feb 2008

11 Feb 2008: Troubleshooting: Intermittent stepper motor failure More...

When the ampere values of the black stepper motor are not calibrated correctly on Magnus 400 and Magnus 400 Quantum platesetters, the stepper motor fails intermittently.
Go to carriage on the Troubleshooting page.

07 Feb 2008: Maintenance kit part number updated More...

The part number for the Basic PM Kit for Fiberhead configurations with MCU has been promoted from 518-00173A to 518-00173B. In addition to the Lotem Fiberhead with MCU configuration, the updated part number is also relevant to the Magnus 400 with MCU and Magnus 400 II with MCU II configurations.
Go to the Parts/tools page.

01 Jan 2008: Procedure: Using the Magnus Output Devices Installation Report Tool More...

This procedure describes how to use the Magnus Output Devices Installation Report Tool. The tool enables field engineers to provide installation feedback to Kodak. After every installation, open the Magnus Output Devices Installation Report Tool and submit the report.
Go to the Installation page.

18 Dec 2007: European compressors for Magnus 400 and Magnus 400 II platesetters More...

For platesetter installations in Europe, two European compressor configurations are available.
Go to the Installation page.

12 Nov 2007: FCO 512-00460A: One-piece load roller More...

FCO 512-00460A installs the improved one-piece load roller to eliminate roller marks on plates during the loading process.
Go to the FCOs page.

03 Nov 2007: Procedure: Adjusting the drum vibration sensors More...

When the drum stops frequently rotating and vibration error messages appear, you need to adjust the position of the drum vibration sensors.
Go to the Procedures page.

TechPlanet DVD Version 6 N.3—01 Nov 2007

10 Sep 2007: FCO 512-00450A: Kit FCO for Magnus 400 Conveyor More...

FCO 512-00450A installs an improved middle support guide and front cover bracket on the plate conveyor to accommodate smaller plate sizes.
Go to the FCOs page.

30 Aug 2007: Troubleshooting: Exposure error appears on Magnus 400 LDA platesetters More...

When the values of the Default First Laser Number and Default Last Laser Number parameters are changed and you start the exposure process, an error message appears.
Go to Exposing on the Troubleshooting page.

03 Jul 2007: Troubleshooting: Plate collides with roller system when exiting punch More...

During the punch entry-to-drum entry stage of the loading sequence, the edge of the plate collides with the support roller.
Go to Plates on the Troubleshooting page.

03 Jul 2007: Procedure: Drilling the drum on Magnus 400 More...

If fog appears on plates on either the head gripper side of the drum or the tail gripper side of the drum, you need to drill additional holes in the drum.
Go to Other procedures on the Procedures page.

25 Jun 2007: Troubleshooting: Smart edge detection fails on Magnus 400 and Magnus 200 platesetters More...

When smart edge detection fails, different error messages appear.
Go to Edge detection on the Troubleshooting page.

25 Jun 2007: Troubleshooting: Recurring “Datapath error” appears on Magnus 400 More...

A recurring nondescript “Datapath error” appears in the Magnus 400 Controller GUI, but does not include information about the error.
Go to error/system messages on the Troubleshooting page.

24 Jun 2007: Troubleshooting: Plate skews during drum loading More...

During the plate-picking stage of the loading sequence, the vertical orientation of one of the suction cups is skewed because a suction cup leg bearing is loosely seated in the XY loading assembly bar.
Go to Loading or Plates on the Troubleshooting page.

17 Jun 2007: Troubleshooting: Jobs abort in the queue after the plate exists the platesetter More...

If you change the Timeout For Shutdown UDRC mSec parameter to a value less than 300,000, jobs get stuck in the queue and the last job might abort.
Go to Xpo on the Troubleshooting page.

TechPlanet DVD Version 6 N.2—01 Jun 2007

12 Jun 2007: Repairing laser diodes on Magnus 200 and Magnus 400 platesetters More...

You can repair a faulty laser diode by splicing one optic fiber from the spare diode to the optic fiber of the faulty (original) diode. Find this item under Other procedures on the Procedures page.

28 May 2007: Troubleshooting: Problems on Magnus 400 after upgrading to Service Shell 2.6 More...

After installing FCO 512-00422A to upgrade from Kodak Service Shell 2.5 to version 2.6, Service Shell does not start. Find this item under Startup on the Troubleshooting page.

02 May 2007: Troubleshooting: RCON startup failure, drum in error state, and the Magnus 400 Controller software does not start on Magnus 400 and Magnus 200 platesetters More...

Warning: Do not change the default MCE IP address on the Magnus 400 platesetter. For more information about troubleshooting these probems, see Startup on the Troubleshooting page.

29 Apr 2007: Magnus 400E site goes live More...

The Magnus 400E site is now live, and includes product description information. We will continue to add information to the site.

News archive


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.