Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
12 Dec 2006: GMCE Controlled Release 2.1 More...
Trendsetter 400/800/NEWS - GMCE Controlled Release 2.1 for GMCE Trendsetter 400/800 III base, Autoloader, ContinuousLoad, and NEWS is posted on the Control/Settings page. GMCE CR 2.1 includes an update for the DCAPI server. This CR can only be installed on GMCE devices.
28 Nov 2006: Translated safety guide and visual reference guide posted More...
Translations of the Trendsetter 400/800 III Visual Reference Guide and Safety Guide for customers are available on the Reference page.
14 Nov 2006: GMCE Trendsetter production starting 15 Nov 2006 More...
Trendsetter 400/800 III with serial numbers starting with TG are in production effective 15 Nov 2006. GMCE information has been added throughout the site including:
Additional updated information and translations will be posted to the site as they are available.
TechPlanet DVD Version 5 N.3—01 Nov 2006
25 Aug 2006: FCO CA10122: Mechanical film guide LEC (away side) guide mount upgrade More...
Use kit number 512-00372A to replace the mechanical film guide’s away side guide mount on Trendsetter devices with serial numbers TM1018 to TM10163. See FCO CA10122 on the FCOs page.
11 Aug 2006: FCO CA10120: Dual struts for front panel More...
Use kit number 512-00368A to replace a failed single strut on devices with serial numbers TM676 to TM1130. See FCO CA10120 on the FCOs page.
11 Aug 2006: New procedure for CA03931 - TS4/TS8 Heidelberg-built devices More...
FCO CA03931 changes TEC reed switches or microswitches to optical sensors to improve reliability. It applies to TS4/TS8 Heidelberg-built devices with serial numbers Sxx386xxxx (TS400/800) and Sxx385xxxx (TS4). The procedure involves replacing the old TEC backbone with a new TEC backbone. This FCO should only be applied if there have been repeated failures of the TEC backbone, clamp microswitches, and/or reed switches. Do not apply this FCO for an individual switch failure.
24 Jul 2006: Speed upgrade procedure for TS3 devices revised More...
The TS3 speed upgrade procedure has been revised to correct the scale of the templates in Appendix A. See Trendsetter Upgrades on the Overview or Procedures page.
28 Jun 2006: Troubleshooting: MPE firmware errors 16008 or 16010 on machines running CR 1.4 More...
If MPE firmware errors 16008 (Total mainscan shift less than or equal to zero) or 16010 (Total mainscan shift too large) occur on a Trendsetter output device running Controlled Release 1.4, firmware patch TTSB255R1 is now available to fix this problem. For more information, see the new troubleshooting item, posted on the Troubleshooting page.
21 Jun 2006: Controlled Release 5.3 More...
Trendsetter 400/800 Controlled Release MCE 5.3 for MCE Trendsetter 400/800 base, Autoloader, ContinuousLoad, Spectrum, and Auctus is posted on the Control/Settings page. MCE CR5.3 includes service dongle control of Service Shell and supports a minimum mainscan size of 270 mm on manual devices. See the Trendsetter MCE Controlled Release 5.3 Readme/Release Notes for more information.
07 Jun 2006: Site preparation guide More...
The English version of the Trendsetter 400/800 II Site Preparation Guide has been updated and posted on the Installation page. The revisions include improved footprint and work area diagrams, and corrections to electrical connector information for Europe and United Kingdom.
02 Jun 2006: Trendsetter specifications updated More...
The Trendsetter 400 II Quantum, 800 II, 800 II Quantum, VMR, and KRS specifications have been revised to include X-speed, smaller plate size capability, and updated performance information. See the Overview page.
TechPlanet DVD Version 5 N.2—01 Jun 2006
11 May 2006: New MCE geometric correction parameters document More...
A new document describing the MCE firmware parameters used to adjust geometric correction on Trendsetter 400/800 II, Autoloader, ContinuousLoad, Spectrum, and NEWS output devices has been added to the Procedures page.
10 May 2006: Static balancing of the drum on MCE output devices in the field More...
A procedure for static balancing of the drum on MCE output devices in the field has been added to the Procedures page. This procedure may be required in situations where there is excessive device vibration. Kit number 518-01763A is required to complete this procedure.
17 Apr 2006: Lytron Heat Exchanger replaces the PolyScience Chiller on Trendsetter VLF and Trendsetter 3230/3244 devices More...
The Lytron heat exchanger is a replacement for the PolyScience chiller. It can be installed on any Trendsetter VLF and Trendsetter 3230/3244 (TS3 and TS3/8) output device that has a 40W, TH1.7 thermal imaging head.
This is a Next Failure replacement. For full details see the Heat Exchanger page.
21 Mar 2006: Trendsetter MCE Controlled Release 5.2 and Trendsetter base MPE Controlled Release 1.4 More...
Trendsetter MCE Controlled Release 5.2 and Trendsetter base MPE Controlled Release 1.4 are posted on the Control/settings page. Information on major features and fixes is included in the MCE Trendsetter 4/8 Controlled Release 5.2 Readme/Release notes and MPE TRENDSETTER Base CONTROLLED RELEASE 1.4 ReadMe/Release Notes.
13 Mar 2006: Japanese translation of the Trendsetter 400/800 II Site Preparation Guide More...
See the Installation page for the Japanese translation of the Trendsetter 400/800 II Site Preparation Guide.
07 Mar 2006: Operator and visual quick reference guides available in simplified Chinese More...
See the Reference page for the simplified Chinese translation of the Trendsetter 400/800 II operator and visual quick reference guides.
20 Feb 2006: Increased media sensitivity on V- and X-speed devices More...
Increased media sensitivity on V- and X-speed devices is normal. Check the CTP media database for the correct drum speed and estimated power setting, then refer to the media tech note for the detailed setup procedure.
For an example, see section 6.3 of the Kodak Thermal Gold Technical Note.
Download the latest CTP Media Imaging Performance Database. For more details on media qualification and settings, see the Media site.
20 Feb 2006: Controlled Release 5.0 and 5.1 field upgrades More...
Before doing a field upgrade to CR 5.0 or 5.1, you must be familiar with the requirements and processes for installing Creo Feature Licensing. See Trendsetter 400/800 Controlled Release MCE 5.0 and Trendsetter 400/800 Controlled Release MCE 5.1 on the Control/Settings page.
16 Feb 2006: Creo Feature Licensing (CFL) information More...
A site about Creo Feature Licensing (CFL) replaces the Creo Feature Licensing page. Click Feature Licensing under Related sites in the side menu to access the CFL site.
TechPlanet DVD Version 5 N.1 and Mature Products 2006—31 Jan 2006
30 Jan 2006: Translations of the Trendsetter 400/800 II Site Preparation Guide More...
See the Installation page for Dutch, French, German, Spanish, Italian, and Chinese versions of the Trendsetter 400/800 II Site Preparation Guide.
20 Jan 2006: Trendsetter upgrades information posted (4-page and 8-page) More...
An upgrade page is available that explains speed and other possible upgrades according to the type, version, and serial number of the Trendsetter output device. See Trendsetter Upgrades on the Overview or Procedures page.
20 Dec 2005: Update 1 for Trendsetter 400/800 base, AL, CL, and Spectrum Controlled Release MCE 4.1 More...
This update fixes a flyoff problem for Spectrum devices and reduces the hold current of the unload table traveller motor to prevent the motor from overheating on Autoloader and ContinuousLoad devices. See Trendsetter 400/800 Controlled Release MCE 4.1, Update 1 on the Control/Settings page.
14 Dec 2005: Trendsetter MCE Controlled Release 5.1 More...
CR 5.1 is a factory-installed controlled release for MCE Trendsetter 400/800 base, Autoloader, ContinuousLoad, Spectrum, and Auctus. Do not upgrade to this release in the field unless 5.0 is installed or it is an X-speed upgrade. Information on major features and fixes is included in the MCE TRENDSETTER 4/8 CONTROLLED RELEASE 5.1 Release Notes.
06 Dec 2005: Trendsetter 800 II/NEWS MCE Thermal Head 1.7 to 2.x Upgrade procedure More...
The Trendsetter 800 II/NEWS MCE Thermal Head 1.7 to 2.x Upgrade Procedure for X-speed has been added to the Procedures page.
25 Nov 2005: Trendsetter 400/800 II Site Preparation Guide updated More...
The Trendsetter 400/800 II Site Preparation Guide, posted on the Installation page, has been updated with Kodak branding, and more accurate dimensions and weights for output device and shipping crates.
08 Nov 2005: New TH1.0 20 W, 2400 dpi head for Kodak Sword media More...
A new TH1.0 (20 watt) 2400 dpi head is available in limited quantities for use with Kodak Sword media only. The new head utilizes a side-looking focus block, eliminating the problems experienced by the regular TH1.0 centre-looking focus block when trying to image Kodak Sword plates. See the Thermal Head 1/1.7 Overview page for specifications. The new TH1.0 head is not a free FCO—it is on the price list as a field upgrade:
25 Oct 2005: Trendsetter 400/800 II ContinuousLoad Field Upgrade Procedure added More...
The Trendsetter 400/800 II ContinuousLoad Field Upgrade Procedure has been added to the Procedures page.
03 Oct 2005: Trendsetter MCE Controlled Release 5.0 More...
CR 5.0 is a factory-installed controlled release for MCE Trendsetter 400/800 base, Autoloader, ContinuousLoad, Spectrum, and Auctus.
CR 5.0 factory installation started at serial number TM894. CR 5.0 was also installed during the beta and prerelease stages on TM741, TM744, TM749, TM753, TM764, TM869, TM870, TM871, TM872, TM873, TM876, TM877, TM879, TM880, and TM883. Information on major features and fixes is included in the MCE TRENDSETTER 4/8 CONTROLLED RELEASE 5.0 Readme/Release Notes.
TechPlanet DVD Version 4 N.3—30 Sep 2005
30 Sep 2005: FCO CA03931: TEC optical sensor upgrade for TS3 and TS3/8 More...
FCO CA03931 changes TEC reed switches or microswitches to optical sensors on TS3 and TS3/8 MPE devices to improve reliability. The procedure involves replacing the old TEC backbone with a new TEC backbone. This FCO should only be applied if there have been repeated failures of the TEC backbone, clamp microswitches, and/or reed switches. Do not apply this FCO for an individual switch failure.
15 Aug 2005: Trendsetter MCE Controlled Release 4.1 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, ContinuousLoad, and Spectrum. MCE Trendsetter 400/800 base, AL, CL, and Spectrum is posted on the Control/settings page. Information on major features and fixes is included in the MCE TRENDSETTER 4/8 CONTROLLED RELEASE 4.1 Readme/Release Notes.
29 Jul 2005: Cylinders page updated More...
The list of cylinders used for Trendsetter 400/800 base, Al, CL and Spectrum has been updated. Links to this page are available on the Parts/Tools pages for Trendsetter 400/800 base, Al, CL and Spectrum.
07 Jul 2005: Escalation contact information for CAP updated More...
The CSC-PSS contact information for CAP has been updated on the Escalation page. The e-mail address has changed and separate phone numbers for Australia and Shanghai are now available.
05 Jul 2005: Trendsetter 400/800 II devices shipping with Thermal Head on device More...
Devices starting with serial numbers TM800 are shipping with the thermal head on the device. There is no additional crate for the head. Coolant is not installed in the system. The revised installation procedure is available on the Installation page.
05 Jul 2005: Reminder: FCO CA04904 to replace load ramp sensor extension cable on some MCE devices More...
This Next Visit FCO has not been completed for several devices.
The load ramp sensor extension cable (10-5155A) that was used in devices with serial numbers TM042 to TM467 could fail because the wrong pin was used. For details, see the FCOs page.
05 Jul 2005: FCO CA07165: New cooling system pump and motor More...
FCO CA07165 releases a new, more reliable cooling system pump and motor. If the old pump fails, replace the pump only. If the old motor fails, replace both motor and pump.
Water pump: 378-00008 (non-NEWS 200); 378-00015 (NEWS 200 only)
Motor: 500-02914A (non-NEWS 200); 500-02915A (NEWS 200 only)
This FCO has a priority of Next Failure.
09 Jun 2005: New drum drive amplifier More...
A new model of drum drive amplifier (ACE1200) is in use for Trendsetter 400/800 II starting at serial number TM747. The 100 label number is 18. For information, see Drum amplifier (601-00032).
01 Jun 2005: Trendsetter MPE Controlled Release 1.3 More...
This controlled release is for MPE Trendsetter 400/800 base. Trendsetter 400/800 MPE Controlled Release 1.3 is posted on the Control/settings page. Information on major features and fixes is included in the MPE TRENDSETTER Base CONTROLLED RELEASE 1.3 ReadMe/Release Notes.
TechPlanet DVD Version 4 N.2—31 May 2005
27 May 2005: FCO CA06199: Mean Well power supplies replacing Astec power supplies More...
For a failure of PS1, PS2, PS3, or PS4, order the appropriate kit that includes hardware and a procedure for the power supply replacement. See FCO CA06199 on the FCOs page for details.
25 May 2005: Trendsetter 400/800 Visual Quick Reference guide for TS8 MPE devices More...
See Trendsetter 400/800 Visual Quick Reference guide for TS8 MPE devices (part number 653-00953A-EN-A) on the Reference page.
19 May 2005: Optical encoder troubleshooting checklist More...
The Optical encoder troubleshooting checklist posted on the Procedures and Troubleshooting pages is intended to help when encoder problems are suspected. It should be completed before requesting a shaft encoder upgrade.
05 May 2005: Vibration limitation for Trendsetters More...
Vibration limitation for Trendsetters technical bulletin is posted on the Reference page.
04 May 2005: Enabling film imaging on Trendsetter MCE More...
See Enabling film imaging on Trendsetter 400/800 II (MCE) on the Procedures page.
03 May 2005: FCO CA06616 released: more reliable pivot blocks More...
See FCO CA06616 on the FCOs page for details. Kit 512-00260A includes replacement parts for all pivot blocks and a replacement procedure. This is a next failure FCO.
27 Apr 2005: Installation test checklist for customers and revised installation test procedure posted More...
Service engineers should fill out the new customer installation test checklist (ITC) during the installation test procedure (ITP), have customers sign the checklist, and leave a copy of the checklist on-site. The ITC and revised ITP for Creo service are posted on the Installation page. Translations of the checklists will be posted when they are available.
07 Apr 2005: Trendsetter MCE Controlled Release 4.0 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, ContinuousLoad, and Spectrum. Trendsetter 400/800 MCE Controlled Release 4.0 is posted on the Control/settings page. Information on major features and fixes is included in the MCE TRENDSETTER 4/8 CONTROLLED RELEASE 4.0 ReadMe/Release Notes.
Note that a service dongle is required for some components in CR4.0. Service dongles will be required for future CRs so you should order one soon. See Creo Feature Licensing for ordering information.
31 Mar 2005: Variable Mainscan Resolution information More...
A page about Variable Mainscan Resolution (VMR) has been added to this site. VMR is supported in Trendsetter MCE Controlled Release 4.0. Click on VMR info in the left side menu to access the VMR page.
28 Mar 2005: Troubleshooting: Cooling pump fails or runs intermittently (MCE) More...
If the cooling pump on MCE devices is not running or runs intermittently, the thermal head can overheat. The cause may be poor electrical contacts in the connection box. See the troubleshooting item for information on what to check.
Find a link to this document on the Troubleshooting page under Chiller/cooling.
10 Feb 2005: TEC Optical Sensor Upgrade Procedure for MPE revised More...
The revision is that the procedure works with the current Controlled Release not any version of firmware. See FCO 3738 for MPE for the procedure and other details.
03 Feb 2005: Trendsetter MCE Controlled Release 3.4 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, and Spectrum. CR3.4 includes Thermal Head v1.97 firmware, and Xilinx 2.23. TH 1.x 1.95 firmware had an issue where if the device used multiple media (either plating or proofing), the stroke tables were corrupted. This corruption could result in banding on plate or proof and could be easily misdiagnosed. This is corrected in 1.97. For details, see Trendsetter MCE Controlled Release version 3.4 posted on the Control-Settings page.
TechPlanet DVD Version 4 N.1 and Mature Products 2005—31 Jan 2005
17 Dec 2004: Using the scan <I/O> command to diagnose MCE sensor states More...
A new procedure, Interpreting MCE Sensor I/O Bit States , has been posted on the Procedures page. This document describes how to use the scan <I/O> command to display sensor input bit names and interpret the results.
08 Dec 2004: Troubleshooting: MCE Error #43308: CRG: Carriage travel limit (<xxx>) unexpectedly hit More...
This troubleshooting item describes the actions to perform for service engineers, the Response Center, and shared maintenance customers (where applicable) when this error occurs.
Find a link to this document on the Troubleshooting page.
02 Dec 2004: Warning: TH1.x Head Firmware – Stroke table corruption occurs when switching media, causing image artifacts or banding More...
This affects Thermal 1.x heads with head firmware version 1.93, 1.95, or 1.96 and LVD hardware version 4 or later
If all of the above conditions apply, and the device has more than one media setup, when you switch media the stroke tables may become corrupted and display all 33s. This can cause image artifacts or banding.
If the device you are working on meets all the conditions above and has more than one media setup, even if you are not experiencing image artifacts or banding, complete the following workaround:
Workaround
stroke.head version. You're looking for a Thermal 1.x head with:
set head r6 0.r6 does not exist: Type set head lvreverse 0.nvs save head.The 33s in the stroke tables are active and have not been saved, so resetting the device will clear them. After resetting the device the head will perform a stroke cal automatically on the first plot as each media is selected.
A permanent solution will be rolled out in the next two weeks.
02 Dec 2004: Revised site preparation guide posted More...
The Site Inspection Checklist section of the Site Preparation PDF now contains text fields and check boxes that you can fill in online. See the installation page for details.
02 Dec 2004: Translations of MSDS for pink (82-1032A) and blue (402-00056) chiller coolant available More...
Click the Chiller MSDS link on the safety page.
10 Nov 2004: Flash/BBRAM NVS corruption on MCE boards More...
For details, see the troubleshooting item on the Troubleshooting page.
08 Oct 2004: New troubleshooting item: Carriage driver board 503C01525B power supply feeds noise into MCE board More...
A new troubleshooting item has been posted on the Troubleshooting page, describing the procedure to perform when one or more of the following symptoms occur:
05 Oct 2004: Data channel not detected error (5230) on MCE Trendsetters with Brisque Direct More...
See the troubleshooting item on the Troubleshooting page.
04 Oct 2004: FCO CA05160 released: carriage driver board cable replacement More...
FCO CA00752 introduced a new carriage driver board (503C01525B), which has a switching power supply that generates a high level of electrical noise. This noise is fed into the MCE board via carriage driver board power cable 220-00061A, which can cause SCSI CRC check errors, digital I/O errors, and low-level firmware errors.
FCO CA05160 corrects this problem by replacing the carriage driver board’s power cable with one that connects directly to the power supply instead of a point on the MCE board.
Note: The procedure for FCO CA00752 has also been updated with information about the new cable and how to connect it.
TechPlanet CD Version 3 N.3—30 Sep 2004
20 Sep 2004: Trendsetter MCE Controlled Release 3.3 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, and Spectrum. CR3.3 includes MCE v1.18.15 firmware, Thermal Head v1.95 firmware, Xilinx 1.4, and Service Shell v2.5 SP1. For details, see Trendsetter MCE Controlled Release version 3.3 posted on the Control-Settings page.
30 Aug 2004: Safety Procedures for Service Engineers More...
You must follow Safety Policies for Service Engineers posted on the Safety page to protect yourself, your co-workers and customers.
18 Aug 2004: Checking GENINE board installation More...
When installing the GENINE board, the plastic film MUST be removed from the heat sinking compound on the back of the board. Failure to remove this film can lead to unexpected resets or premature failure of this board. For devices built between 1 April 2004 and 20 July 2004, please verify that the GENINE board has been installed correctly. See Checking GENINE board installation on the Procedures page
13 Aug 2004: New troubleshooting items posted More...
See the Troubleshooting page for the following items:
06 Aug 2004: New troubleshooting item - PLL Lock errors - MCE More...
See PLL Lock errors - MCE on the Troubleshooting page.
06 Aug 2004: FCO to replace load ramp sensor extension cable on some MCE devices More...
The load ramp sensor extension cable (10-5155A) that was used in devices with serial numbers TM042 to TM467 could fail because the wrong pin was used. For details, see the FCOs page. This is a Next Visit FCO.
06 Aug 2004: New procedure posted More...
A new procedure has been posted on the Procedures page: Measuring engine, picker, and table actuator times and adjusting actuators.
28 Jul 2004: Trendsetter 400/800 II Visual Quick Reference posted More...
See the Reference page.
20 Jul 2004: General exception fault after replacing MPE board More...
MPE boards (10-3692B) with serial numbers 1A0049xx and date code 2004-05-12 were shipped without the NVS parameters and state variables initialized. For details on fixing the problem, see the General exception fault after replacing MPE board troubleshooting item on the Troubleshooting page.
05 Jul 2004: Trendsetter MCE Controlled Release 3.2 Update 1 More...
This update should only be installed to fix specific UDRC problems with Controlled Release 3.2. For details, see the Trendsetter MCE Controlled Release 3.2 Update 1 page.
TechPlanet CD Version 3 N.214 Jun 2004
07 Jun 2004: Revised Carriage Drive Belt Adjustment procedure More...
Three procedures for checking carriage drive belt tension have been revised and combined into one procedure that applies to all 4/8-page Trendsetters. For details, see the Procedures page.
27 May 2004: FCO to change TEC micro-switches to optical sensors on TS8 MPE devices. More...
The optical sensors will provide improved reliability. Order kit #512-00083A for TS8 MPE devices. For details, see the FCOs page. This is a Next Failure FCO.
20 May 2004: TECs with optical sensors fail to lock or unlock More...
On some MCE devices, the screws for the TEC sensors may not be tight. This can interfere with the motion of the lock/unlock cylinder. Devices with serial numbers TM329 to TM335 should be checked. For details, see the TECs with optical sensors fail to lock or unlock troubleshooting item on the Troubleshooting page.
19 Apr 2004: Specifications revised More...
The following specifications have been updated on the Overview page:
01 Apr 2004: Problems with control over the external chiller More...
On the recent version of the PolyScience chiller, which is a grey model rather than black, there is an error in the interface connector on the back. The interface has a cable detect that signals the device firmware to turn the coolant pump and the compressor on/off, but some chillers have the incorrect interface installed. See the Troubleshooting page for a workaround that will fix the cable detect and give some control over the chiller. A field change order (FCO) will be issued later to provide a permanent fix.
01 Apr 2004: Test Plot Applet procedure posted More...
A procedure for Using Test Plot Applet(TPA) is available on the Procedures page For more detailed information on TPA, see the Service Shell online help.
26 Mar 2004: FCO to change TEC micro-switches to optical sensors on MCE devices. More...
The optical sensors will provide improved reliability. Order kit #512-00112A for MCE devices. For details, see the FCOs page. This is a next PM FCO.
15 Mar 2004: Revised PM and Uptime/Spares kits More...
Updated Planned Maintenance and Uptime/Spares kits are posted on the Maintenance and Parts pages. See Trendsetter 400/800 PM kits - Excel spreadsheet and Trendsetter Uptime/Spares Kits - Excel spreadsheet.
08 Mar 2004: Revised Specifications More...
Specifications have been updated. See the Overview page.
TechPlanet CD Version 3 N.129 Feb 2004
05 Feb 2004: Xitron RasterBlaster is an unsupported configuration More...
Recently we have seen a number of installations of the Xitron RasterBlaster system directly connected to a Trendsetter. Please be aware that this is an unsupported configuration. If you come across any such installation, please report it to Trendsetter Product Development. For details, see the Connectivity page.
05 Feb 2004: BBRAM corruption troubleshooting item More...
On MCE devices there have been random occurences of BBRAM corruption. For details see Machine electronics failed power on self-tests on the Troubleshooting page.
04 Feb 2004: Trendsetter MCE Controlled Release 3.2 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, and Spectrum. CR3.2 includes MCE v1.18.10 firmware, Thermal Head v1.93 firmware, and Service Shell v2.5. For details, see the Control-Settings page. This is a next visit FCO.
29 Jan 2004: FCO to change drum amp shunt resistor on MCE devices More...
Drum amp shunt resistor for MCE devices improved to prevent damage by high surge of current. For details, see the FCOs page. This is a next failure FCO.
11 Dec 2003: Carriage Driver Upgrade for MPE/MCE More...
This Carriage Driver Upgrade for MPE/MCE will increase the performance and reliability of Trendsetter carriage systems. The new carriage driver board operates from a single 48V power supply and does not need PS3 to operate. This FCO is applicable to TS8 (MPE) & TSM (MCE) devices that use a 48V carriage driver. See FCO CA00752 for details.
19 Nov 2003: Trendsetter MCE Controlled Release 3.0 More...
This controlled release is for MCE Trendsetter 400/800 base, Autoloader, and Spectrum. CR3.0 includes MCE 1.18 firmware, and Service Shell 2.5. For details, see the Control-Settings page. This is a next visit FCO.
25 Sep 2003: MOVs and spark gaps are being removed from devices (ECO CA01804) More...
Creo MPE devices are no longer being shipped with metal oxide varistors (MOVs) and spark gaps between line and ground. The MOV assemblies (part number 10-4018A) should be removed from units in the field (serial numbers TE 799 and earlier) at the next PM visit. See FCO CA01804 for details.
17 Sep 2003: Lookup tables need updating More...
With Controlled Release 2.0 for MCE devices, customers still running Brisque version 4.0.97 must update the lookup tables before their device will be recognized. See the "Brisque Direct Update.txt" patch file in the root of the Controlled Release CD (651-00057A) for instructions on doing this.
TechPlanet CD Version 2 N.3/415 Sep 2003
15 Sep 2003: Problem With Backing Up NVS Parameters When Using Service Shell v2.4 SP1 More...
The installer file for Service Shell v2.4 SP1 is generating an error message when NVS parameters are backed up. The message will read:
29 Aug 2003: Trendsetter MCE Controlled Release 2.0 More...
CDs are now available for Controlled Release MCE 2.0 for the Trendsetter 400/800, Trendsetter AL and Trendsetter Spectrum. This controlled release is the early production release for MCE Spectrum and includes MCE 1.14 firmware and Media Console version 1.2. For details, see the Control-Settings page. This is a next visit FCO.
25 Aug 2003: 10-4766D version boards are not yet available. More...
Order 10-4766C if you have to replace an MCE board.
11 Aug 2003: Dutch Translation of Trendsetter 400/800 (TSM version) Operator Manual posted More...
See the Reference page for Dutch version of the Trendsetter 400/800 (TSM version) Operator Manual.
29 Jul 2003: Kit available for air leaks near U47 sensor on MCE board More...
A kit is available for air leaks near the U47 sensor on 10-4766D-D and earlier MCE boards. For details, see FCO CA01716 on the FCOs page.
25 Jul 2003: Trendsetter MCE Controlled Release 1.2 More...
CDs are now available for Controlled Release MCE 1.2 for the Trendsetter 400/800 and Trendsetter AL. The MCE 1.2 controlled release includes Print Console 3.4 and MCE firmware required for Brisque 4.1. For details, see the Control-Settings page. This is a next visit FCO.
11 Jul 2003: Translations of Trendsetter 400/800 PM Checklist for Customers More...
See the Maintenance page for French, German, Spanish, Italian, and Japanese versions of the Trendsetter 400/800 Planned Maintenance Checklist for Customers.
03 Jul 2003: Translations of Trendsetter 400/800 (TSM version) Operator Manual posted More...
See the Reference page for French, German, Spanish, Italian, and Japanese versions of the Trendsetter 400/800 (TSM version) Operator Manual.
24 Jun 2003: Trendsetter MCE Controlled Release 1.2 not available at this time
29 May 2003: Calibration procedure for 15-3330 drum amps More...
Before replacing a 15-3330 drum amp on an MPE device, try to calibrate it using the Calibrating the 15-3330 drum amp procedure on the Procedures page.
29 May 2003: Trendsetter MCE Controlled Release 1.2 More...
CDs are now available for Controlled Release MCE 1.2 for the Trendsetter 400/800. The MCE 1.2 controlled release includes Print Console 3.4 and MCE firmware required for Brisque 4.1. For details, see the Control-Settings page. This is a next visit FCO.
28 May 2003: Replacement carriage driver board for MCE devices More...
503C01525B replaces 10-4935C. For kit information, see FC0 CA00663 on the FCOs page.
07 May 2003: Trendsetter MPE Controlled Release 1.2 and MCE Controlled Release 1.1 More...
CDs are now available for Controlled Release MPE 1.2 and MCE 1.1 for the Trendsetter 400/800. The MPE 1.2 controlled release includes MPE firmware to support small plates and fourth pin on devices with a 4 pin drum, and Service Shell 2.4 SP1. The MCE 1.1 controlled release includes updated Xilinx firmware code (1.65) and Service Shell 2.4 SP1. For details, see the Control-Settings page. This is a next visit FCO.
TechPlanet CD Version 2 N.228 Apr 2003
23 Apr 2003: Planned Maintenance Checklist for Customers More...
In response to customer requests, an initiative is underway to improve how scheduled maintenance is documented and tracked. One part of the initiative is to ensure that every device is checked for safety and overall operation first, before each assembly is assessed and cleaned/fixed. Once the PM work is finished, the customer is given a list of what has been done and asked to sign off on it. The advantage to Creo is that once the signed PM documents are filed centrally, we have a complete maintenance history for each machine.
The new customer checklist is to be filled out by the service engineer during a PM visit, signed by the customer, and a copy left on site. The customer PM checklist and procedures for Creo service are on the Maintenance page.
23 Apr 2003: MPE to MCE: Two new documents have been posted More...
The following documents have been posted to the MCE Info page:
14 Apr 2003: Communication or air flow problems with the UDRC-LC (chemistry-free option) More...
If the Trendsetter 400/800, Trendsetter AL, or Trendsetter Spectrum device is unable to communicate with the UDRC-LC (chemistry-free option), or an error of a possible leak or blockage in air flow is reported, the Lionel board should be hard reset. For details, see UDRC-LC on the Debris Removal Troubleshooting page.
14 Apr 2003: Image shift away from the LEC More...
On some MCE devices there have been random shifts where the image is shifted away from the LEC. For details see Image shift away from the LEC.
08 Apr 2003: Trendsetter 800 II and Trendsetter 800 II Quantum specifications More...
Trendsetter 800 II and Trendsetter 800 II Quantum specifications are available on the Overview page.
03 Apr 2003: Type II performance improvements More...
Information regarding sales and marketing, order management and customer support, as well as an FAQ regarding the new performance has been compiled at Performance improvements with 8 page CTP
28 Mar 2003: Trendsetter MCE Information Page More...
This page contains information that is specific to Trendsetter MCE devices. Note that the terms Type II, TSM, and MCE are all used to refer to Trendsetter MCE in Trendsetter documentation.
All of the information listed on Trendsetter MCE Info is also available on the relevant pages within the Trendsetter 400/800, Trendsetter AL and Trendsetter NEWS sites.
14 Mar 2003: Trendsetter 400/800/ Trendsetter VLF Installation procedure updated More...
The Trendsetter 400/800 Installation procedure has been revised for rebranding, MCE, and to replace the label placement appendix with links to the procedures on the Installation page.
27 Feb 2003: Plate alignment labels on the Trendsetter 400/800 (MCE) More...
A procedure for placing plate alignment labels on Trendsetter 400/800 (MCE) has been posted on the Installation page. The procedure is different to the one for Trendsetter 3244 because there are four registration pins and smaller plate sizes can be used.
The Trendsetter 400/800 Installation procedure has been revised for rebranding, MCE and to replace the label placement appendix with links to the procedures on the Installation page.
26 Feb 2003: New imaging times More...
INTERNAL and CONFIDENTIAL. The MCE Trendsetter devices have new drum speed settings that allowed us to eliminate interleaving from all models. Refer to the drum settings table on the Control/Settings page to determine the proper drum settings for different speed and head configurations. For more information or detail, please contact Steve Froese.
25 Feb 2003: Recommended carriage settings for MCE devices More...
Please ensure that all Trendsetter MCE devices have the carriage parameters set according to the carriage settings table on the Control/Settings page.
24 Feb 2003: Cracked clamp plates More...
There have been some cases of the clamp plates breaking in production. Inspect these on next visit or PM. For details see Cracked or broken clamp plates.
17 Feb 2003: Kit available for UDRC-LC connectivity on MCE devices. More...
Kit# 512-00043 provides UDRC connectivity for Chemistry-free option (LC) on MCE Trendsetters. See FC0 CA00386 on the FCOs page.
11 Feb 2003: Trendsetter MPE Controlled Release 1.1 More...
The second MPE Controlled Release CD is now available for the Trendsetter 400/800. This Controlled Release includes version 1.83 firmware for Thermal Head 1.7 and Service Shell 2.4. For details, click on MPE Controlled Release version 1.1 on the Control-Settings page.
TechPlanet CD Version 2 N.125 Jan 2003
24 Jan 2003: TSM (MCE) Specifications, Operator Manual and Site Prep posted More...
Specifications, Operator Manual and Site Prep documents for Trendsetter 400/800 (TSM/MCE) are now available. See the
23 Jan 2003: UDRC included with all Trendsetter 400/800, Trendsetter Autoloader and Trendsetter Spectrum devices More...
All Trendsetter 400/800 devices (MPE and MCE) except Trendsetter NEWS and Proofsetter Spectrum are now shipped with a UDRC for debris removal. See the Debris Removal site for more information about the UDRC.
21 Jan 2003: TH1.7 does not come online on MCE device More...
Some new or replacement 1.7 thermal heads may not come online when an MCE device is powered up for the first time. A script is required to initialize the head. See the Troubleshooting page for more information.
20 Jan 2003: Trendsetter 400/800 MCE in limited Early Production More...
Trendsetter 400/800 MCE is in limited Early Production for base and Autoloader. MCE enables smaller plate size (9x12) and speed improvements.
All Trendsetter 400/800 MCE devices will be shipped with a UDRC.
All non-Quantum Trendsetter 400/800 MCE devices will be shipped with a P33 head.
Trendsetters that require Brisque Direct will be MPE devices until Brisque Direct has been qualified on Trendsetter MCE devices.
MCE hardware, firmware and other documentation has been added to the site. Check the overview page for more early production information, reference page for operator manual and training links, control/settings page for MCE firmware information, parts page for MCE parts lists.
The Escalation process is the same as for MPE but be sure to indicate whether you are reporting on an MPE or MCE machine. Serial numbers for MCE machines start with TM.
14 Jan 2003: PPP Server for MCE TCP/IP Serial Connection with Print Console More...
A document for Configuring Windows 2000 as a PPP Server for MCE TCP/IP Serial Connection with Print Console has been posted on the Procedures page.
TechPlanet CD Version 1 N.426 Oct 2002
24 Oct 2002: Replacement cables and sensors for load ramps, load tables, and unload pans More...
Fretting on contacts between cable and sensor was causing loss of connection. A new cable and sensor should be installed for improved reliability. See E897 on the FCO page for appropriate kit number and procedure.
16 Oct 2002: Kit for replacement TEE boards More...
If you have to replace a TEE board, order kit 518-00003. The kit includes the board plus necessary fittings. See FCO CA00063 on the FCO page.
09 Oct 2002: Planned Maintenance Checklist Revised More...
The checklist is divided into numbered sections with approximate time required so that you can divide the PM procedures according to customer schedule. Each section can be performed independently. After each section, you can return the device to operational status. See the Maintenance page for the revised Trendsetter 400/800 PM checklist.
16 Sep 2002: Missing or incorrect deadband calibration on some 15-3466 drum drive amps More...
Some 15-3466 components were shipped from the manufacturer with an incorrect or completely ignored deadband calibration. The device may fail drum initialization intermittently. See the troubleshooting item for information on how to check the deadband calibration to see if the drum drive amp should be replaced.
11 Sep 2002: Revised specifications for Trendsetter 400/800 More...
See the specs on the Overview page.
06 Sep 2002: Processless name changed to Chemistry-Free More...
Processless has been changed to Chemistry-Free - internal documents will be renamed on next revision.
29 Aug 2002: Processless imaging option(UDRC-LC) for Trendsetter 400/800 More...
ECO E740 includes a UDRC-LC upgrade kit for Trendsetter 400/800 and installation/upgrade procedure. UDRC parts page also updated.
24 Jul 2002: Bad batch of drum brake control boards (#10-4795A-B) More...
A small number of drum brake control boards (#10-4795A-B) used for both the TS8 and NEWS were faulty. Drum Amp Displays Code 5 includes a procedure to check on whether the board is faulty.
24 Jul 2002: Common drum for TS8 and NEWS More...
A common drum (50-2111) is now used for both the TS8 and NEWS. It can be identified by the crescent-shaped brass counterweight mounted on the endbell. This drum requires a belt tension of 70Hz. See E404 on the FCO page for more information.
22 Jul 2002: Longer cable and hose for UDRC-B More...
Some customers find the UDRC too noisy. The kit now includes longer hoses and cables so that the unit can be placed farther away from the device operator. See E921 on the FCO page for more information.
18 Jul 2002: Unimaged Strip Seen on Positive Plates after an MPE Firmware Upgrade More...
At sites where customers use positive plates, avoid a
firmware upgrade unless it is absolutely necessary. An artifact has been
seen lately on Trendsetter VLFs and Trendsetter Spectrums, and it is
suspected that it affects all MPE-based devices. The artifact is an unimaged
strip, 0.5 to 1.0 mm wide, visible on positive plates at the away end of the
plate. The solution to the problem is to downgrade to an earlier version of
the MPE firmware.
If you must do a firmware upgrade because you are replacing a thermal
head, or for some other reason, see the troubleshooting
note for tests to verify that the plates will be free of the problem and
for a possible workaround if the problem does occur.
TechPlanet CD Version 1 N.2/3—12 Jul 2002
12 Jul 2002: General Guidelines for F to V Speed Upgrades More...
are available on the Overview page. Check the price list or contact Steve Froese for information on specific upgrades.
10 Jul 2002: Version B of TEE boards can still be usedMore...
Verion B and version C of the TEE board (10-3672) can be used for FCO D547. When ordering a TEE board, please ask for version B so that the stock can be used. Information about FCO D547 is on the FCOs page.
28 Jun 2002: Trendsetter Controlled Release MPE 1.0 More...
The first Controlled Release CD is now available for the Trendsetter 400/800 base (FCO E854). A Controlled Release is a package of software/firmware components that have been tested for compatibility with each other and with Trendsetter hardware. All machines should be upgraded to the latest controlled release version at the next visit. For details, click on Controlled Release version 1.0 on the Control-Settings page.
26 June 2002: Tech Bulletin: New Push Panel for 4/8 Page Trendsetters More...
A new technical bulletin describes the simpler latch on the side access panel for 4/8 page Trendsetters. See the Reference page.
20 June 2002: Load Ramp Plate Sensor Troubleshooting More...
Guidelines for troubleshooting problems with the load ramp plate sensors have been added to the Troubleshooting page.
03 May 2002: Carriage Problems More...
Strange behavior of the carriage, including stalling and excessive motor temperature, could be caused by faulty capacitors on the carriage drive board (10-3761B). Before replacing the board or motor, follow the steps in the troubleshooting note Overcurrent in Carriage Drive Boards
03 May 2002: Power & Environmental Site Surveys More...
Creo has a contract with Rx Monitoring Services in
Manchester, NH (603-666-6606 ext201) to provide Power & Environmental
Site Surveys for the NAFTA region. The monitoring service includes voltage,
current, temperature, humidity, dust and air pressure. Rx will provide the
equipment to be installed at the customer site (for a maximum of 10 days),
monitor it and send an e-mail report.
Air pressure monitoring is the latest addition to the Power &
Environmental Site Survey. See Installing the Rx Air Pressure Sensor for
details.
15 Mar 2002: Plate Damage During Unload Caused by Warped Load Ramp Glass More...
Some of the glass used in the load ramp is bowed from side to side and plates are hitting the bottom edge of the glass during the unload sequence. The type of damage you're likely to see is bending or crumpling of plates, and/or scratching on the back of plates. You may also find metal debris on the glass or in the machine. See troubleshooting note for more detail.
12 Mar 2002: New "Drum Tick" Firmware Command More...
Use the "drum tick" command to help troubleshoot encoder issues. For detailed instructions, see Firmware Engineering's drum tick page.
01 Mar 2002: Cable Too Short on ECO E120 - TEC Magnet Microswitch Upgrade More...
The cable assembly (10-4947A), in kits 05-2023 (TS4) and
05-2024, needs to be replaced with a longer version 10-4947B. Existing kits
cannot be rev'd to add the new cable, though a new cable will be added to
WIP and future kits. Instead service logistics will ship the new, longer
cable 10-4947B with any order it gets for kits 05-2023 or 05-2024.
If you perform FCO E120
on any Trendsetter 4/8 page device, be sure you get the cable along with the
05- kit and use the longer B version cable when performing the upgrade. If
you have performed this upgrade to any devices in the past, please order
10-4947B and replace it on the next visit.
01 Mar 2002: Incorrect Part Number on Relay Delay Board More...
Our PCB vendor has been mislabeling the relay delay control board used in ALL output devices. The correct part number for the board is 10-3701D, and the vendor has been labeling it with 10-3743D. If you are replacing this board, order the 10-3701D part number rather than the part number on the board. Also, please use a permanent marker to correct the part number on any board you find in the field with the incorrect part number.
TechPlanet CD Version 1 N.1—15 Feb 2002
26 Jan 2002: Top Panel Latching [FCO] More...
Redesign of the top panel to accommodate a new Southco latching mechanism. Service needs to order the new hinge when replacing the top panel. For parts information, see Top Panel Kit.
16 Jan 2002: Fan box [FCO] More...
Door uses a latching mechanism that is not visible from the outside. To open the door, push FIRMLY on the top of the door. The first base machine to ship is TE422 and the first Proofsetter is PX096. For service implications, see FCO E243
06 Jan 2002: Consumables for Preventative Maintenance More...
All consumable items required for maintenance can be ordered from either Bedford or the Response Centre. See list and instructions: Maintenance Consumables
Technical Library CD Version 5.4—23 Oct 2001
06 Sep 2001: Replacement for Load Ramp Sensor [FCO] More...
Load ramp sensor #36-3141 has wrong focal length. Replace with #36-3210. See FCO E312 for information.
27 Aug 2001: Dehumidifier unit replaces Desiccant box [FCO] More...
The dehumidifier unit has replaced the desiccant box in all new Trendsetter machines. See FCO E246 for upgrade procedure.
Technical Library CD Version 5.3—23 Jul 2001
05 Jul 2001: Protocol for Debris Removal of Processless Media More...
The purpose of this Protocol is to provide a uniform procedure for evaluating airborne emissions from CreoScitex systems while they are imaging ablative printing media. See the Imaging System Airborne Emissions Assessment Protocol
12 May 2001: Release of Firmware Version 2.51A/B More...
Release of firmware version 2.51A/B (ECO D207. )For details see firmware pages. Note: this f/w requires MPE board 10-3692A, preferably version E.
05 May 2001: TEC Backbone Microswitches Replace Unreliable Reed Switches [FCO] More...
Unreliable TEC backbone reed switches are replaced with microswitches (15-3478) will now be used. See FCO E120 for more information.