Number Error Message
33256     BFD: Not in download state
33257     BFD: Firmware already in download mode
33258     BFD: Binary file download not complete
33259     BFD: Invalid download handle
33260     BFD: Binary File Header bytes were not zero
33261     BFD: Binary File Illegal Tag value(s) found
33262     BFD: Unknown download type
33263     BFD: unknown destination type specified
33264     BFD: Bad checksum calculated
33265     BFD: DOWNLOAD START message received, but not in IDLE state
33266     BFD: CPU reset type equals boot level
33267     BFD: Unknown Flash Manufacturer
33268     BFD: Unknown Flash Device or Failure Identifying Flash Device
33269     BFD: Failure writing flash
33270     BFD: Failure writing FW Dir entry for BBR Code
33271     BFD: Failure writing FW Dir entry for Xilinx
33273     BFD: No firmware directory entries available
33274     BFD: Error code not used
33276     BFD: Binary Upload data is exhausted
33277     BFD: Failure writing FW Dir entry for Overwriting data
33501     MSG: Message not reserved
33502     MSG: Invalid argument list
33503     MSG: Incorrect message type
33504     MSG: Incorrect message group
33505     MSG: Command queue is empty
33506     MSG: Timeout waiting on command queue
33507     MSG: String queue is empty
33508     MSG: Timeout waiting on string queue
33509     MSG: Message not released
33510     MSG: No messages in pool remaining
33511     MSG: Timeout waiting for message response
33512     MSG: Maximum head message is 31 bytes
33513     MSG: Failure Sending String Message - Queue Full
33514     MSG: No strings in pool remaining
33516     MSG: Message tracing is disabled
33517     MSG: Zero message trace buffers are allocated
33518     MSG: Internal firmware error
33519     MSG: Command code is filtered and not logged into trace buffer
33520     MSG: Message tracing is not disabled, cannot perform requested action
33521     MSG: Reached the end of the message trace buffer list
33522     MSG: No more free message trace filter entries
33523     MSG: A trace filter with the specified command code exists
33524     MSG: Command code not in trace filter list
33600     STG: Storage Key was not found
33601     STG: Storage Key data block is the wrong size
33602     STG: Storage medium is corrupt
33603     STG: Storage medium is full
33604     STG: More than one type of non-volatile storage medium specified
33605     STG: Invalid Subsystem Number specified for Key
33606     STG: Invalid Private Key Number specified for Key
33607     STG: End of NVS storage found
33608     STG: Storage Medium was recovered from backup
33609     STG: Access to STG Subsystem was Blocked
33610     STG: Invalid function parameter passed to an STG API function
33611     STG: Duplicate Key(s) present in NVS
33612     STG: The type of NVS specified does not exist in this product.
33613     STG: Attempted to write past the end of a STG RAM search table
33614     STG: The specified configuration code is invalid
33615     STG: The specified Nvs medium is not supported by the called function
33616     STG: Configuration failed
33617     STG: Storage medium is not initialized, it cannot be used
33618     STG: Storage medium is corrupt, it cannot be used
33619     STG: Storage medium is corrupt - key data checksum failed
33620     STG: Storage medium is corrupt - key storage control block checksum failed
33621     STG: Storage medium is corrupt - initialized values not set
33622     STG: Invalid storage partition
33623     STG: Invalid storage granularity
33624     STG: Cannot recover NVS medium, only one partition available
33700     MON: Diagnostic NT pipe to SVCHOST is not created
33701     MON: undefined error for monitor command
33702     MON: Failed to create a line editor component
33703     MON: The line editor has disabled forwarding to the terminal
33900     ERR: Description not found
33901     ERR: Too many error groups defined
33903     ERR: No error descriptor partitions left
33904     ERR: Test: <test string pointer> <test decimal value 16-bit integer> <test string pointer> <test pseudo float value (32-bit integer> <test string pointer> <test long 32-bit unsigned integer> <test string pointer> <test 16-bit hexadecimal value>
33905     ERR: Error group is invalid
33906     ERR: Error parameter overflow
33907     ERR: Firmware integrity failure
33908     ERR: Parameterized error table is full, all indexes are reserved
33909     ERR: Error buffer has overrun
33910     ERR: Error buffer is invalid
34000     PRM: Invalid function parameter(s) sent into API function
34001     PRM: Invalid parameter group identifier
34002     PRM: Duplicate registration of parameter group table
34003     PRM: Invalid parameter group table
34004     PRM: Duplicate parameter key found
34005     PRM: Invalid parameter key
34006     PRM: The search is complete
34007     PRM: The buffer size specified does not match buffer size for NVS parameter key
34008     PRM: The specified group description has not been found
34009     PRM: The parameter has not been found
34010     PRM: The parameter copy index is invalid
34011     PRM: The parameter element index is invalid
34012     PRM: The parameter syntax is invalid
34013     PRM: The parameter range is invalid (name="<Name of offending parameter>" key=<Key of offending parameter>)
34014     PRM: The string parameter syntax is not supported
34015     PRM: The string parameter length is invalid
34016     PRM: Unexpected software failure
34017     PRM: The functionality has not been implemented
34018     PRM: The PRM command is in progress
34019     PRM: No parameter table was registered for this group
34020     PRM: A zero is sent as the DataLength function parameter
34021     PRM: The PRM internal data buffer size is too small
34022     PRM: No more available overflow system table entries
34023     PRM: The group descriptions are inconsistent
34024     PRM: The NVS system table is corrupt
34025     PRM: NVS medium is corrupt
34026     PRM: STG subsystem General failure
34027     PRM: The NVS medium is full
34028     PRM: A STG key already exist with a different data block size
34029     PRM: Parameter key not found in NVS
34030     PRM: No default is associated with parameter
34031     PRM: No NVS is detected
34032     PRM: Parameter subsystem is not initialized
34033     PRM: Cannot modify parameter, not in configuration mode
34034     PRM: Cannot modify parameter, not in media mode
34035     PRM: The specified configuration code is invalid
34036     PRM: Configuration failed.
34037     PRM: Command cancelled
34038     PRM: This parameter is read-only
34039     PRM: Restricted parameter, insufficient access level
34040     PRM: This parameter is not accessible from the diagnostic monitor
34041     PRM: Parameter '<Group name><Index reference> <Short name><Element name>' changed from <Original value> to <New value> <Units>
34101     UTL: no saved records in history table
34102     UTL: invalid parameter
34103     UTL: pipe handle is invalid
34104     UTL: pipe is now full
34105     UTL: pipe is now empty
34106     UTL: data pipe could not be created
34107     UTL: data pipe could not be deleted
34108     UTL: Reached the end of a linear link list
34109     UTL: Memory Allocation Failure
34110     UTL: The pipe information has not registered
34111     UTL: Pipe is opened
34112     UTL: Connecting NT pipe
34113     UTL: Pipe not connected, cannot retrieve pipe name
34114     UTL: Failed to create and connect NT Pipe
34115     UTL: The destination pipe id is invalid
34116     UTL: The source pipe id is invalid
34117     UTL: The buffer to hold PipeName is too small
34118     UTL: Failed to read from NT pipe
34119     UTL: Sending too much data through an NT pipe
34120     UTL: Cannot disable interrupts when performing link list index search
34121     UTL: Conversion failed, software error
34122     UTL: No data is ready in the specified queue
34123     UTL: Cannot read from the board's IIC port
34124     UTL: Cannot write to the board's IIC port
34125     UTL: Fixed-size queue full
34126     UTL: Fixed-size queue empty
34127     UTL: Invalid format type for conversion
34128     UTL: Invalid engineering units for conversion
34129     UTL: Attempted to register too many override function tables
34130     UTL: Attempted to override the same function more than once
34131     UTL: Cannot override function because function cannot be found
34132     UTL: Cannot override function because override table not registered
34133     UTL: Attempt to register override table or override function after system initialization
34200     BCM: invalid port ID specified
34201     BCM: internal buffer space full
34202     BCM: timeout waiting for ACK
34203     BCM: general failure
34204     BCM: internal buffers exhausted
34205     BCM: HDLC CRC receiver error
34206     BCM: failure to create WIN32 thread
34207     BCM: client receive buffer too small
34208     BCM: received HDLC pkt not for us
34209     BCM: port is in 'Raw' mode
34210     BCM: can't send, no Carrier Detect
34211     BCM: timer thread create failure
34212     BCM: out of virtual connection buffers
34213     BCM: virtual connection was lost
34214     BCM: no more internal HDLC buffers
34215     BCM: transmit timeout multiplex error
34216     BCM: no multiplex communications occuring
34217     BCM: The BCM_PORT is not of type NT Pipe
34218     BCM: Invalid function parameter detected
34219     BCM: The pipe information has not registered
34220     BCM: Pipe is opened
34221     BCM: Connecting NT pipe
34222     BCM: Pipe not connected, cannot retrieve pipe name
34223     BCM: Failed to create and connect NT Pipe
34224     BCM: The destination pipe id is invalid
34225     BCM: The source pipe id is invalid
34226     BCM: The buffer to hold PipeName is too small
34227     BCM: Failed to read from NT pipe
34228     BCM: The specified BCM port is not opened
34229     BCM: Sending too much data through an NT pipe
34230     BCM: Baud Rate specified is too high
34231     BCM: Invalid Baud rate
34232     BCM: Transaction List Underflow
34233     BCM: HDLC Address Invalid or Unknown
34234     BCM: DOP Address Invalid or Unknown
34235     BCM: DNE-ICE Auto ID failure
34236     BCM: DNE-ICE Communication setup failure
34237     BCM: DNE-ICE Communication shutdown failure
34238     BCM: DNE-ICE connection failure
34239     BCM: DNE: receive timout failure on ICE data
34240     BCM: Transmission Cancelled
34241     BCM: Can't open W32 serial Port
34242     BCM: Can't initialize comm port buffers in Win32
34243     BCM: Access attempted to unsupported port in Win32
34244     BCM: Error while closing port
34245     BCM: Error while writing to port
34301     DPC: undefined pattern number
34302     DPC: close of closed scan
34303     DPC: close of un-open scan
34304     DPC: write to undefined scan
34305     DPC: call with NULL pattern struct
34306     DPC: Too many cells in pattern
34307     DPC: Pattern write call error
34308     DPC: write to un-opened scan
34309     DPC: write to closed scan
34310     DPC: open of NULL scan
34311     DPC: memory overflow
34312     DPC: too many scans
34313     DPC: timed out waiting for stripe to complete
34320     DPC: SCSI Driver Error, line <Line Number>
34321     DPC: SCSI driver error, invalid initiator
34322     DPC: SCSI asynchronous transfer requested, line <Line Number>
34323     DPC: SCSI parity error detected
34324     DPC: SCSI bus reset detected
34331     DPC: orthog slope smaller than minimum, check plate rotation
34332     DPC: orthog slope larger than max, check plate rotation
34333     DPC: OCCT SDRAM Test fail - Address = <Address>, Write data = <Write data>, Read data = <Read data>
34334     DPC: SDRAM module was not detected
34335     DPC: RIP resolution is invalid
34336     DPC: Pixels per stroke is invalid
34337     DPC: Subscan duplicate is invalid
34338     DPC: Mainscan duplicate is invalid
34339     DPC: Drum diameter is invalid
34340     DPC: Mainscan length is invalid
34341     DPC: Mainscan length is not a multiple of 32
34342     DPC: Pixels per stroke is not a multiple of 8
34343     DPC: DPC subsystem received unknown command message
34344     DPC: Stroke width not a multiple of subscan replication
34345     DPC: Reserved Error Code 1
34346     DPC: Reserved Error Code 1
34350     DPC: Data transfer already in progress
34351     DPC: Data transfer not in progress
34352     DPC: memory test not defined
34353     DPC: memory test failed at address
34354     DPC: too much data has been received
34355     DPC: too little data has been received
34356     DPC: Data channel not detected
34357     DPC: Datapath operation was preempted
34358     DPC: Image padding limit was exceeded
34359     DPC: No blank regions available for use
34360     DPC: No blank regions currently being used
34361     DPC: Invalid OCCT pointer send to datapath
34800     RIF: Image property parameter not found in list
34801     RIF: Image property list is invalid
34802     RIF: Image property type is invalid
34803     RIF: Message type is invalid
34805     RIF: Cannot merge image property lists
34810     RIF: Received invalid command code from workstation
34811     RIF: Received invalid parameter from workstation
34812     RIF: Command code received from workstation is not supported
34813     RIF: Received non-zero value in reserved field from workstation
34820     RIF: No more resolutions supported
34821     RIF: Resolution mode not defined
34822     RIF: Invalid resolution specified
34823     RIF: No more media supported
34855     RIF: Too many timestamps in timing loop-back packet
34856     RIF: Cannot timestamp a non timing loop-back packet
34857     RIF: Signifies that the packet represents a timing loop-back
34858     RIF: The input function parameter is incorrect
34900     RTL: failure
34901     RTL: no free transactions
34902     RTL: no match
34903     RTL: full
34904     RTL: addressing conflict
34905     RTL: no route found
34906     RTL: timeout
34907     RTL: port not opened
34908     RTL: NT COM port or pipe conflict
34909     RTL: Invalid Source Id String
34910     RTL: Invalid Destination Id String
34911     RTL: Cannot determine which DNE instance to connect to
34912     RTL: RTL transaction has already been freed
34913     RTL: No Communications to Target Device
34914     RTL: Route buffer is reserved by non-streaming messages
34915     RTL: The indexed RTL transaction is invalid
34916     RTL: Invalid CDI communication profile
34917     RTL: BCM port cannot be opened
34918     RTL: Linked List Protection Semaphore Fault
34919     RTL: Transaction flushed from RTL list
35702     PRD: unable to find subsystem name
35703     PRD: unable to find specified record
35706     PRD: unable to find specified subsystem number
35707     PRD: called function is not applicable for this product
35708     PRD: version information has already been registered
35709     PRD: version information has not been registered yet
35710     PRD: The run-time option specified does not exist
35711     PRD: Could not save the run-time option setting to NVS
35712     PRD: Flyoff occurred, remove media
35713     PRD: Flyoff sensor blocked, check machine for loose media, or check flyoff sensor
35720     PRD: Safety sense is not on, check doors and emergency off switch
35722     PRD: Media partially loaded on drum, cannot move nor spin drum
35724     PRD: Emergency stop switch is on
35733     PRD: Front panel is open, check front panel
35738     PRD: Cannot unlock doors if the drum is spinning
35741     PRD: Invalid Temperature Reading Attempted
35742     PRD: Drum brake override is on, cannot spin drum
35743     PRD: Invalid NVS key in callback
35744     PRD: The write laser could not be turned on because the safe line is not high
35748     PRD: System Presence Fault: <Presence detect bit description> (<Presence detect bit name>) Not Detected
35749     PRD: System Input Fault: <Input bit description> (<Input bit name>) In Unexpected State
35750     PRD: System Output Fault: <Output bit description> (<Output bit name>) In Unexpected State
35751     PRD: System Range Fault: <Analog bit description> (<Analog bit name>) Out Of Range: Low=<Low range limit>, High=<High range limit>, Reading=<Current value>
35752     PRD: System Range Warning: <Analog bit description> (<Analog bit name>) Out Of Range: Low=<Low range limit>, High=<High range limit>, Reading=<Current value>
35756     PRD: Drum is spinning when a stationary drum is expected
35757     PRD: Hardware can't generate requested tach simulation velocity
35760     PRD: head logic power not enabled, cannot plot
35766     PRD: Invalid model configuration specified
35772     PRD: System Pressure Out of Range: Reading=<Low range limit>, Low=<High range limit>, High=<Current value> (<Analog group name>)
35777     PRD: Fatal error triggered
35778     PRD: Invalid callback
35779     PRD: User issued an abort, use 'abort clear' to clear the abort
35780     PRD: <Group name> Presence Fault: <Presence detect bit description> (<Presence detect bit name>) Not Detected
35781     PRD: <Group name> Input Fault: <Input bit description> (<Input bit name>) In Unexpected State
35782     PRD: <Group name> Output Fault: <Output bit description> (<Output bit name>) In Unexpected State
35783     PRD: <Group name> Range Fault: <Analog bit description> (<Analog bit name>) Out Of Range: Reading=<Current value>, Low=<Low range limit>, High=<High range limit>
35784     PRD: <Group name> Range Warning: <Analog bit description> (<Analog bit name>) Out Of Range: Reading=<Current value>, Low=<Low range limit>, High=<High range limit>
35785     PRD: <Group name>: All faults cleared
35787     PRD: Away Side Balance actuator extended, cannot spin the drum
35788     PRD: Home Side Balance actuator extended, cannot spin the drum
35790     PRD: Model code is invalid or unavailable
35791     PRD: Limit tag is not specified in the limit table
35792     PRD: Invalid optional value found. Limit tag [<Limit Tag>]. Value <Optional Value>.
35793     PRD: <Limit description> is <Limit value> <Unit>. <Parameter> <Unit> exceeds the limit.
35794     PRD: <Limit description> is <Limit value> <Unit>. <Parameter> <Unit> is lower than the minimum.
35795     PRD: <Limit description> must be <Limit State>.
35796     PRD: <Limit description> do not contain option flag <Option flag>. Cannot enable the option.
35797     PRD: <Limit description> is <Limit value> <Unit>. <Parameter> <Unit> is not equal to the limit.
35798     PRD: Key switch is on, drum speed limited to <Drum Speed> RPM
35800     _376: reset induced by software watchdog
35801     _376: reset induced by halt monitor
35802     _376: reset induced by RESET opcode
35803     _376: reset cause unknown
35804     _376: reset triggered by crash dump handler
36001     VBS: specified subsystem number is not registered
36002     VBS: specified output device is not applicable for this product
36501     BRD: Internal Error - Failed to create a Nucleus PLUS Timer
36502     BRD: Internal Error - Failed to control a Nucleus PLUS Timer
36503     BRD: Internal Error - Failed to Reset a Nucleus PLUS Timer
36504     BRD: Flash Driver code does not support this command primitive
36505     BRD: Flash Driver code has failed to program flash memory
36506     BRD: Flash Driver code has failed to erase a flash sector
36507     BRD: Insufficient memory to hold assembler flash driver routines
36508     BRD: The flash memory write operation failed to verify
36509     BRD: The address specified does not point to flash memory
36510     BRD: No Xilinx (LCA) was found in flash memory
36511     BRD: Undefined error
36512     BRD: Undefined error
36513     BRD: Board temperature sensor initialization failed
36514     BRD: No Overwriting pattern file (OVWR) was found in flash memory
36800     HLT: DNE not initialized (set DNE init 1)
36801     HLT: Invalid Parameters Sent to HLT Function
36802     HLT: Requested element is not registered
36803     HLT: Requested subsystem is not registered
36804     HLT: Internal HLT Subsystem Error
36805     HLT: A Subsystem has timed out
36806     HLT: Subsystem reported with unrecoverable error
36807     HLT: No cable detected between DNE and ICE
36808     HLT: BCM comm. between DNE and ICE has stopped
36809     HLT: The specified print unit is currently offline
36810     HLT: No Subsystem has reported in yet
36811     HLT: The system/subsystem is starting up
36812     HLT: Subsystem shutdown is currently taking place
36813     HLT: HLT subsystem has not initialized
36814     HLT: Workstation is not detected
36815     HLT: Feature is not available yet
36816     HLT: Firmware resource is low
36817     HLT: Print unit is online, connection checking not done
36818     HLT: SCSI Disk has errors
36819     HLT: SCSI disk not detected
36820     HLT: End of list detected
36821     HLT: Board temperature is above threshold
36822     HLT: Board temperature is above maximum limit
36900     MCE: Insufficient Heap Memory - required for DF1 serial drivers
36901     MCE: WMD Subsystem RCON Incoming Command Register Failure
36902     MCE: SDRAM Operation Failure
37420     PHS: TH2 error [<error code>] <error string>
37701     DRS: software error
37702     DRS: Drum operation timed out
37703     DRS: Drum is reserved, command ignored
37704     DRS: Overflow in internal drum calculation
37705     DRS: Tach simulator preventing drum servo control
37706     DRS: The current drum command has been preempted
37707     DRS: Drum servo control missing interrupts
37708     DRS: Specified drum velocity out of range
37709     DRS: Drum Hardware Missing <Description of the faulted hardware component>
37710     DRS: Drum Position Counter Overflow
37711     DRS: Specified Drum Torque out of range
37712     DRS: Drum Position Not Settling
37713     DRS: Drum Velocity Exceeded 100 Rpm in Torque mode
37714     DRS: Drum Velocity Error Exceeded
37715     DRS: Drum can't move to position at zero velocity
37716     DRS: Drum failed to reach position
37717     DRS: Number of allowable drum callbacks exceeded
37718     DRS: Drum target velocity invalid for PLL calculations
37719     DRS: Drum parameter patch range error: <Name of the drum NVS parameter that can not be patched because>
37720     DRS: Drum command passed an invalid pointer parameter
37721     DRS: Drum cannot use an encoder resolution of 0
37722     DRS: Drum can't stop at position when not moving
37723     DRS: Operation blocked while drum is freewheeling
37801     LCA: Xilinx LCA program failed
37802     LCA: Xilinx LCA file not found
37803     LCA: Xilinx LCA file checksum error
37804     LCA: LCA interrupt failed to register callback properly
37805     LCA: Feature not supported by the Xilinx firmware
37806     LCA: Invalid Latch ID specified
37807     LCA: Xilinx configuration failed
37808     LCA: SDRAM operation failed
37809     LCA: Overwriting pattern verification failed
37810     LCA: Invalid Overwriting Pattern detected
37811     LCA: Hardware can't generate requested tach simulation velocity
37812     LCA: <Feature> requires at least Xilinx v<Major version number>.<Minor version number>, current Xilinx is v<Major version number2>.<Minor version number2>
37813     LCA: Overwriting pattern <PatternID> is not licensed on this device
38101     MPC: Plot has been aborted
38102     MPC: Plot Mode is out of range or not valid
38104     MPC: Not configured for <Mainscan resolution> by <Subscan resolution> DPI resolution
38105     MPC: Startscan delay <Startscan delay> sub-pixels must be at least zero
38106     MPC: Total startscan delay <Startscan delay> sub-pixels is too large
38107     MPC: Mainscan image size <Mainscan image size> pixels too large, maximum is <Maximum image size> pixels
38108     MPC: Could not find edge of media after <Search attempts> attempts
38109     MPC: Head not configured for '<Media name>/<Media colour>/' media
38110     MPC: The carriage start position <Carriage start position> mm is beyond the home tab
38111     MPC: Timeout waiting for image data
38113     MPC: No resolution modes configured
38115     MPC: Invalid plot parameter ('<Parameter name>' = <Parameter value>)
38116     MPC: No valid edge found, check edge detect strip
38117     MPC: Internal: Invalid parameter passed to function
38118     MPC: Internal: System resource unavailable
38119     MPC: Midpoint position <Midpoint position> um too small for subscan media size
38120     MPC: Phase Lock Loop losing lock
38121     MPC: Debris removal not running as expected
38122     MPC: The '<Sequence name>' sequence is currently being processed
38123     MPC: The Phase Lock Loop could not be started
38124     MPC: The Phase Lock Loop cannot accommodate <Mainscan resolution> DPI
38125     MPC: The drum speed is too high for imaging, maximum is <Maximum drum speed> RPM
38126     MPC: The Xilinx firmware must be upgraded
38127     MPC: Mainscan image size <Mainscan image size> pixels must equal gapless drum circumference <Drum circumference> pixels
38128     MPC: Mainscan shift <Mainscan image shift> um larger than gapless drum circumference
38129     MPC: The specified sequence is not supported
38130     MPC: The pattern stroke width (<Pattern stroke width>) must equal the head (<Head stroke width>)
38134     MPC: Multiple plates detected on drum
38136     MPC: Subscan output resolution of <Subscan output resolution> DPI must equal head resolution
38138     MPC: Invalid media stack identifier <Media Stack Identifier> specified
38139     MPC: Cancel ignored, no sequence in progress
38142     MPC: Subscan image size <Subscan image size> pixels too large, maximum is <Maximum image size> pixels
38143     MPC: Internal: Expected plot sequence is not active
38144     MPC: The carriage end position <End position> mm is beyond the maximum travel distance <Maximum carriage travel> mm
38145     MPC: The media is sensitive to retraces and one or more retraces occurred
38146     MPC: Forced failure
38147     MPC: Head is not yet initialized
38148     MPC: Xilinx version <Current major version>.<Current minor version> is invalid, must be at least <Minimum required major version>.<Minimum required minor version>
38149     MPC: The head model installed is incompatible with this machine
38150     MPC: Image data sent to the head was possibly corrupted. Check plate for artifacts
38151     MPC: Invalid media type (<Media type>) for this operation
38152     MPC: Total amount of clamp shadow is too large
38153     MPC: Slave head resolution: <Head resolution on the slave board> DPI does not match with the one on the master: <Head resolution on the master board> DPI
38154     MPC: Slave head swath width: <Head swath width on the slave board> does not match with the one on the master: <Head swath width on the master board>
38155     MPC: Overwriting not allowed with pixel replication
38156     MPC: Specified thickness of gapless media must be 0
38158     MPC: Timed out waiting for plot engine to initialize
38159     MPC: Communication failed between master and slave MCE boards
38161     MPC: The Phase Lock Loop did not stabilize
38164     MPC: Not configured for <Subscan resolution> DPI subscan resolution
38165     MPC: Variable mainscan resolution is not supported
38166     MPC: Carriage position is wrong - carriage has probably stalled
38167     MPC: <Head name> image is outside of the head's range (position <The position that triggered the error> um)
38168     MPC: Could not find seam after <Number of attempts> attempts
38169     MPC: Seam could not be verified for fine search
38170     MPC: Seam not found using fine search
38171     MPC: Raster image data received from workstation was possibly corrupted. Check plate for artifacts
38172     MPC: Timed out waiting for raster image data CRC from workstation
38173     MPC: All heads are currently disabled
38176     MPC: Swath width is invalid, extra scanlines <Extra scanlines for current media> >= stroke width <Head stroke width>
38177     MPC: Media subscan size <Media Subscan Size> um is too long for registration pin configuration
38180     MPC: Slave error buffer overflow, unable to read slave error
38181     MPC: Plotting speed <Calculated carriage speed> mm/sec (<Pixels advanced per drum rotation> PPR at <Drum speed> RPM) exceeds licensed limit of <Carriage speed limit>
38183     MPC: Drum speed <Target drum speed> is too fast for <Target resolution> DPI resolution, maximum is <Maximum drum speed> RPM
38184     MPC: The media type '<Media name>' is not currently allowed on this device
38185     MPC: Current stroke width of <Current Stroke Width> is greater than allowed maximum of <Maximum Licensed Stroke Width>
38186     MPC: Workstation Fault [<Image error code>] <Image error text>
38187     MPC: Measured diameter different from expected: Measured (<Diameter measured>) - Expected (<Diameter expected>)
38188     MPC: '<Sequence table>', sequence '<Sequence>' (<Sequence address>), failure action <Failure action> not found
38189     MPC: ExtraScanlines and StrokeWidth set incorrectly for the yaw test pattern
38190     MPC: Phase Lock Loop possibly losing lock, error = <Phase error microns> microns (<Phase error clock cycles> clock cycles)
38191     MPC: The head unexpectedly reset
38192     MPC: The <Plate identifier> is positioned <Error distance> mm too close to the <Error direction> side
38193     MPC: The <Plate identifier> is positioned too close to the <Error direction> side
38194     MPC: The write laser is stuck calibrating
38195     MPC: The gc mainscan shift is too small
38197     MPC: The head is over the media at the minimum edge search position
38200     MIC: Error message with no error code
38201     MIC: Software error
38202     MIC: No image tasks available
38203     MIC: Image task is not active
38204     MIC: Image task is busy
38205     MIC: Image task is not suspended
38206     MIC: Image parameter is missing
38207     MIC: Image parameter is invalid
38208     MIC: Currently not initialized, waiting for FLUSH
38209     MIC: Flush is not complete
38210     MIC: Image parameters already received
38211     MIC: Too many image tasks requested
38212     MIC: Already unloading media
38213     MIC: Image cancelled by flush
38214     MIC: Cannot free unreserved image task
38215     MIC: Invalid image task identifier
38216     MIC: Cannot free busy image task
38217     MIC: Cannot free busy image task
38218     MIC: Fatal error
38219     MIC: Software error: <Additional information on the software error>
38220     MIC: Command aborted
38221     MIC: Task specified is not a valid image task
38222     MIC: Task specified cannot be cancelled
38223     MIC: Task has error, but a second error has occurred
38224     MIC: Image task specified is not a valid image (or not currently running)
38225     MIC: Task specified could not be found (no matching state machine)
38226     MIC: Task cancelled
38227     MIC: Task has not completed
38228     MIC: Flush not currently active
38229     MIC: Group index not in valid range
38230     MIC: Group image index not in valid range
38231     MIC: Group not valid, no images
38232     MIC: Invalid callback supplied
38233     MIC: Invalid image status structure supplied
38234     MIC: Invalid flush status structure supplied
38235     MIC: Invalid task parameter structure
38236     MIC: Invalid image parameter structure
38237     MIC: Invalid image list array supplied
38238     MIC: Invalid state type received in message
38239     MIC: Invalid command ID in command msg
38240     MIC: No state machines available
38241     MIC: State machine not found (no magic number match)
38242     MIC: State machines pointer invalid
38243     MIC: Message invalid, cannot parse
38244     MIC: Conditional false - internal only
38245     MIC: Invalid media type structure
38246     MIC: Media instance not being used by MIC
38301     MDS: Software error
38302     MDS: Software error, unable to allocate sequence data structure
38303     MDS: Software error, the Scheduler is trying to use a NULL sequence data struct
38304     MDS: Software error, the Scheduler is trying to use a invalid sequence structure pool
38305     MDS: Software error, the Scheduler is trying to use a invalid sequence structure linked list
38306     MDS: Software error, the Scheduler could not remove the sequence structure from the linked list
38307     MDS: Software error, unable to allocate media data structure
38308     MDS: Software error, the Scheduler is trying to use a NULL media data structure
38309     MDS: Software error, the Scheduler is trying to use a invalid media structure pool
38310     MDS: Software error, the Scheduler is trying to use a invalid media structure linked list
38311     MDS: Software error, the Scheduler could not remove the media structure from the linked list
38312     MDS: Software error, unable to allocate arguments data structure
38313     MDS: Software error, the Scheduler is trying to use a NULL arguments data structure
38314     MDS: Software error, the Scheduler is trying to use a invalid arguments structure pool
38315     MDS: Cancel command failed, Scheduler not currently processing any operation with specified media instance
38316     MDS: Scheduler could not schedule command since it did not have a proper arguments
38317     MDS: Image type specified is not supported by this machine
38318     MDS: Scheduler monitor command failed
38319     MDS: Initialization failed use 'resume' to re-attempt initialization
38320     MDS: Scheduler command aborted
38321     MDS: Scheduler command cancelled
38322     MDS: Software error, suspend button not defined
38323     MDS: No <media name> on the drum to unload
38324     MDS: Scheduler cannot cancel unload commands
38325     MDS: Cannot cancel initialization commands
38326     MDS: Cannot eject during an unload
38327     MDS: Cannot eject media during initialization
38328     MDS: Scheduler sequence is in an unknown state
38329     MDS: The <Media name> on the drum is already being unloaded
38330     MDS: Scheduler has no tasks currently suspended
38331     MDS: Software error, Scheduler received a bad Media Hander task ID in it callback
38332     MDS: Software error, Scheduler received an invalid action type when setting up its arrays
38333     MDS: Invalid parameter sent to monitor command
38334     MDS: Media already on drum, cannot force new media on drum
38335     MDS: The parameter 'media stacks' is not used, only 1 stack available
38336     MDS: The parameter 'bay' is not used, no bays are available on this device
38337     MDS: The parameter 'punch' is not used, no punches are available on this device
38338     MDS: The parameter 'exit' is not used, only one exit on this device
38339     MDS: Attempt to load proofing media without carrier or receiver on drum
38340     MDS: Media scheduler fatal error
38341     MDS: Media type argument is invalid, media type = <Media type value that is invalid>
38342     MDS: Media stacks argument is <Current media stack value>, maximum = <Maximum media stack value>
38343     MDS: Media stacks argument cannot be 0, must be 1 or greater
38344     MDS: Bay argument cannot be 0 for an automatic job
38345     MDS: Bay argument is <current bay argument>, maximum is <maximum number of bays>
38346     MDS: Bay argument is <current bay argument>, but it is a manual job so it should be 0
38347     MDS: Punch argument is <current punch argument>, maximum is <maximum number of punches>
38348     MDS: Exit argument is <current exit argument>, maximum is <maximum number of exits>
38349     MDS: Rotate argument is <current rotate argument>, rotator is not supported
38350     MDS: Image side argument is invalid, must be set to a defined value for this media
38351     MDS: Image side argument is not valid for this media, must be set to Side A
38352     MDS: Image side argument is greater than expected, set to a valid value
38353     MDS: Default load arguments have been reset to valid values
38354     MDS: Default unload arguments have been reset to valid values
38355     MDS: Invalid media instance, 0 is not a valid media instance
38356     MDS: Invalid media instance, does not match media on the drum
38357     MDS: Requested media is not loaded
38358     MDS: Stack locations specified for <number of stack locations specified> stack(s), however <number of stacks being loaded> stack(s) are being loaded
38359     MDS: Cannot unload <media type> since it is still being loaded (possibly suspended)
38360     MDS: Cannot unload <media type> since <media being loaded on top> is being loaded on top
38361     MDS: Cannot unload <media type> since <media name(s) on top> is/are loaded on top
38362     MDS: Media Scheduler operation is undefined
38363     MDS: Media Scheduler <Operation Sequence Type> operation (<Media Instance ID>) cannot be run because the Media Handler is not initialized
38364     MDS: Media Scheduler <Operation Sequence Type> operation (<Media Instance ID>) is not allowed to be cancelled
38365     MDS: Media Scheduler <Operation Sequence Type> operation (<Media Instance ID>) could not schedule cycle testing operations (error:<Error code>)
38366     MDS: Media Scheduler operation <Media Instance ID> has an unknown sequence type <Sequence Type>
38367     MDS: Media Scheduler <Operation Sequence Type> operation (<Media Instance ID>) could not find a sequence to run
38368     MDS: Media Scheduler could not find step Id <Step Id> in sequence
38369     MDS: Media Scheduler <Operation Sequence Type> operation (<Media Instance ID>) could not find synchronization step Id <Step Id> in sequence (process Id:<Process Id>)
38370     MDS: Media Scheduler could not find end step in sequence
38371     MDS: Media Scheduler step tracking is undefined
38372     MDS: Media Scheduler <Operation Sequence Type> operation <Media Instance ID> has reached its maximum step count <Maximum Step Count> for step Id <Step Id> (process Id<Process Id>)
38373     MDS: Media Scheduler <Operation Sequence Type> operation <Media Instance ID> has an undefined process
38374     MDS: Media Scheduler <Operation Sequence Type> operation <Media Instance ID> could not start a new process (maximum of <Max process count>)
38375     MDS: Media Scheduler <Operation Sequence Type> operation <Media Instance ID> could not find process <Process Id>
38376     MDS: Media Scheduler could not finish sequence scan, too many steps (maximum <Maximum number of scan steps>)
38377     MDS: Media Scheduler could not schedule bay close since the bay is not open
38378     MDS: Media Scheduler could not schedule bay close since one was already scheduled
38379     MDS: Media Scheduler decision type is not supported for step type
38380     MDS: Too many alternate bays, maximum is <Maximum number of alternative bays>
38381     MDS: The media type '<Media name>' is not currently allowed on this device
38400     NET: TRECK TCP/IP Stack is reporting a Fatal Error condition
38401     NET: Failure to activate SLIP link-layer protocol
38402     NET: Failure to activate PPP Server link-layer protocol
38403     NET: Failure to activate PPP Client link-layer protocol
38404     NET: Failure to activate EtherNet link-layer protocol
38405     NET: Failure to allocate internal memory - FATAL
38406     NET: Failure to add a device driver to TRECK TCP/IP Stack - FATAL
38407     NET: Failure to open a device driver for the TRECK TCP/IP Stack - FATAL
38408     NET: Interface device driver for the TRECK TCP/IP Stack is not open
38409     NET: Failure to query information about a h/w interface in the TRECK TCP/IP Stack - FATAL
38410     NET: Warning in TRECK function <Function name>: <Warning description>\n
38800     WMD: Out of command/prompt/stream handles
38801     WMD: Invalid handle
38802     WMD: Internal error detected
38803     WMD: Solicitor number is currently used
38804     WMD: Command Table Full
38805     WMD: Prompt Descriptor Table Full
38806     WMD: Too many buttons for prompt
38807     WMD: An invalid button code was used
38808     WMD: An invalid prompt ID was used
38809     WMD: Illegal attempt to access prompt object
38810     WMD: Unsupported Workstation protocol
38811     WMD: Device is running\nUNSUPPORTED\nEngineering Firmware
38812     WMD: Invalid Command Code detected
38813     WMD: socket() call has failed
38814     WMD: bind() call has failed
38815     WMD: listen() call has failed
38816     WMD: accept() call has failed
38817     WMD: recv() call has failed
38818     WMD: send() call has failed
38819     WMD: WSAStartup() call has failed
38820     WMD: ioctlsocket() call has failed
38821     WMD: Command is rejected because of service lockout
38822     WMD: Service lockout
38823     WMD: No socket connection with workstation.
38824     WMD: Invalid data unit size RCON parameter in Read Memory or Write Memory command
38825     WMD: Too many workstation status change callbacks have been registered
38826     WMD: The RCON connection to the workstation has been lost
38827     WMD: Workstation is not detected
38828     WMD: Too many workstation command received callbacks have been registered
39101     SIF: SIF/SCON General Failure
39102     SIF: Received an SCON NAK reply
39103     SIF: SCON Operation timed out
39104     SIF: No Free CAN Transmit Buffers available
39105     SIF: The SIF Subsystem has detected a reentrancy attempt
39106     SIF: The SIF Subsystem has not been initialized properly
39107     SIF: The SIF Subsystem has run out of queue buffers
39108     SIF: SIF Serial port Open has failed due to not being activated for SIF serial support
39301     SIO: SIO General Failure
39302     SIO: Failure to Register with SIF
39303     SIO: SAT I/O Node does not exist
39304     SIO: The Unsolicited Callback Information Block has Become Corrupted
39305     SIO: The Call Back Function Specified is Invalid
39306     SIO: Attempt to register too many callbacks with the SIO subsystem
39307     SIO: All SCON Connection resources are in use - no more left
39400     GIM: Invalid Image ID
39402     GIM: Internal firmware error
39403     GIM: Invalid Image Parameter
39404     GIM: Please load a new plate
39405     GIM: Please unload the ejected media
39406     GIM: Required data was locked by another subsystem
39407     GIM: Not ready for Flush End command
39408     GIM: No flush active that can be ended.
39409     GIM: Invalid Flush state detected
39411     GIM: Head not initialized: not ready for query
39412     GIM: Unrecoverable Flush Failure. Device must be reset.
39413     GIM: Invalid Image Task ID detected
39414     GIM: Invalid bay number detected
39415     GIM: WARNING: Bypassed functionality detected
39417     GIM: Carriage command received while carriage is busy
39418     GIM: Invalid carriage velocity value attempted
39419     GIM: Invalid carriage position value attempted
39420     GIM: Invalid latch number
39421     GIM: Invalid sensor number
39422     GIM: Invalid latch value code
39424     GIM: Unexpected Command
39427     GIM: Flush is required before operation permitted.
39430     GIM: Invalid Group ID
39432     GIM: Too many images in Group
39433     GIM: No group available
39434     GIM: The device cannot support the number of stacks queried
39435     GIM: Suspend queue is full, cannot handle any more suspends
39436     GIM: Suspend could not be found, not removed
39437     GIM: Please load carrier
39438     GIM: Please unload the ejected carrier
39439     GIM: Invalid group parameter
39440     GIM: Please load receiver
39441     GIM: Please load donor
39442     GIM: RCON command is missing argument '<Name of the missing parameter name>'
39443     GIM: Invalid RCON variable argument specified '<Name of the invalid argument name>'
39444     GIM: Unknown or invalid property ID specified
39445     GIM: Invalid operation attempted on property '<Name of the DCAPI property could not be manipulated>'
39448     GIM: RCON media instance is unknown or invalid
39449     GIM: The system is attempting to simultaneously access too many media instances
39450     GIM: No media is available. Requested media operation cannot be performed.
39451     GIM: Property Not supported
39452     GIM: Invalid arguments specified in Set Seam Geometry request
39453     GIM: Prompt array full, cannot make new prompt
39454     GIM: Could not find prompt
39455     GIM: Workstation command locked out
39457     GIM: Invalid or unsupported combination of arguments
39458     GIM: Service move command received while device is processing a previous move command
39459     GIM: The imaged area is not yet available for reading
39461     GIM: Please load a new plate on the home side
39462     GIM: Please load a new plate on the away side
39463     GIM: Please load a new plate in the center
39464     GIM: Please load two new plates
39465     GIM: Status Handler table full
39466     GIM: Workstation watchdog timed out. Shutting down all systems.
39469     GIM: Bay media configurations must match for transfer
39471     GIM: Invalid arguments specified in Set Punch Regions request
39472     GIM: Not enough free Media Handler descriptors to start a new Media Handler operation
39473     GIM: Media Handler operation specified could not be found
39501     IOS: software error
39502     IOS: Insufficient memory to create IO scanner tables
39503     IOS: I/O Bit not found in product table
39504     IOS: I/O Group not found in product table
39505     IOS: Event group pointer is null
39506     IOS: Can't assign non-input bit to event group
39507     IOS: IO values are not initialized
39508     IOS: Bypass not allowed on this I/O
39509     IOS: No remote address for requested bit
39510     IOS: No remote address for requested bit
39511     IOS: Invalid IOS mode
39512     IOS: IO Name Identifier too long
39513     IOS: Incorrect number of IO Data bytes
39514     IOS: Workstation command locked out
39515     IOS: Conversion function not available
39516     IOS: Callback table full
39517     IOS: Bit handle already has an event registered
39518     IOS: Satellite board address <The satellite board ID that is not responding> register <The register address being accessed> not responding
39519     IOS: TCP/IP failure
39800     SST: Invalid API Function Parameter Detected
39801     SST: Internal SST error
39802     SST: Invalid SST handle
39803     SST: Status group not registered
39804     SST: Invalid SST I/O type
39805     SST: Specified I/O not found
39806     SST: Invalid upper and lower thresholds for analog I/O
39807     SST: Invalid digital target value
39808     SST: Invalid I/O failure priority level
39809     SST: System is not in initialization mode
39900     MBT: Fatal Error - Fell out of Monitor code
39901     MBT: Fatal Error - Boot Code is Corrupt
39902     MBT: Fatal Error - Insufficient Heap Memory available
40001     SMC: Software error
40002     SMC: CAN communication error
40003     SMC: Cannot issue command, motor is moving [<Name of the stepper motor>]
40004     SMC: Cannot issue command, motor is being controlled by another process and is reserved [<Name of the stepper motor>]
40005     SMC: Motor number out of range or the motor is not configured on this device
40006     SMC: Invalid trajectory queue address specified [<Name of the stepper motor>]
40007     SMC: Invalid parameter specified [<Name of the stepper motor>]
40008     SMC: Invalid velocity value specified [<Name of the stepper motor>]
40009     SMC: Invalid acceleration value specified [<Name of the stepper motor>]
40010     SMC: Invalid micro step rate specified [<Name of the stepper motor>]
40011     SMC: Invalid current specified [<Name of the stepper motor>]
40012     SMC: Invalid direction mode parameter specified [<Name of the stepper motor>]
40013     SMC: Remote hardware is not processing motor commands [<Name of the stepper motor>]
40014     SMC: Stepper motor name not found
40015     SMC: Motor unexpectedly hit the home sensor [<Name of the stepper motor>]
40016     SMC: Motor unexpectedly hit the away sensor [<Name of the stepper motor>]
40017     SMC: Stepper command timed out [<Name of the stepper motor>]
40018     SMC: The remote board hardware status check has failed [<Name of the stepper motor>]
40019     SMC: Invalid motor gain parameter specified [<Name of the stepper motor>]
40020     SMC: Motor initialization has failed [<Name of the stepper motor>]
40021     SMC: Remote motor has not been initialized [<Name of the stepper motor>]
40022     SMC: Invalid update mode parameter specified [<Name of the stepper motor>]
40023     SMC: Invalid position specified [<Name of the stepper motor>]
40024     SMC: Invalid steps per real unit specified [<Name of the stepper motor>]
40025     SMC: Invalid distance specified [<Name of the stepper motor>]
40026     SMC: Invalid initialization parameters specified [<Name of the stepper motor>]
40027     SMC: Command failed, the shared motor is using all the remote bandwidth [<Name of the stepper motor>]
40028     SMC: Invalid initialization dual stepper mode specified [<Name of the stepper motor>]
40029     SMC: Move command preempted
40030     SMC: Failed to detect 48V [<Name of the stepper motor>]
40031     SMC: Failed to detect alternate sensor cable [<Name of the stepper motor>]
40032     SMC: Failed to detect home and away cable [<Name of the stepper motor>]
40033     SMC: Failed to detect power cable [<Name of the stepper motor>]
40034     SMC: Failed to detect data cable [<Name of the stepper motor>]
40035     SMC: Over current fault detected [<Name of the stepper motor>]
40036     SMC: Over temperature fault detected [<Name of the stepper motor>]
40037     SMC: Under voltage fault detected [<Name of the stepper motor>]
40038     SMC: Driver fault detected [<Name of the stepper motor>]
40039     SMC: Failed to detect the cable [<Name of the stepper motor>]
40040     SMC: Brake override detected [<Name of the stepper motor>]
40041     SMC: Invalid maximum jerk value specified [<Name of the stepper motor>]
40042     SMC: Input value is outside the limits [<Name of the stepper motor>]
40043     SMC: Satellite board has reset, stepper control has failed [<Name of the stepper motor>]
40044     SMC: Velocity of <Velocity specified in real units/s> units/s [<Velocity specified in steps/s> steps/s] is too high, max is <Maximum velocity allowed in real units/s> units/s [<Maximum velocity allowed in steps/s> steps/s] [<Name of the stepper motor>]
40045     SMC: Velocity of <Velocity specified in real units/s> units/s [<Velocity specified in steps/s> steps/s]is too low, min is <Minimum velocity allowed in real units/s> units/s [<Minimum velocity allowed in steps/s> steps/s] [<Name of the stepper motor>]
40046     SMC: Motor already has a reset callback [<Name of the stepper motor>]
40047     SMC: Satellite board does not support quarter current mode [<Name of the stepper motor>]
40048     SMC: The motor has been stopped before the motor has started [<Name of the stepper motor>]
40049     SMC: Remote motor is waiting for an acknowledge [<Name of the stepper motor>]
40050     SMC: Remote motor has failed with an undefined error <The undefined error> [<Name of the stepper motor>]
40200     MDH: <motor name> stepper motor has already started the command, cannot start it again
40201     MDH: Software error. Media Handler error occurred, but error has no error code.
40202     MDH: Software error. Suspend received a invalid suspend button type.
40203     MDH: Software error. Media Handler received an unrecognized command.
40206     MDH: Command Failed. Media Handler already running another task.
40207     MDH: Cannot cancel command. Media Handler task is not currently executing any commands.
40208     MDH: Media handler task is currently suspended.
40209     MDH: Media handler is not currently suspended.
40212     MDH: Media Handler task cancelled
40213     MDH: Media released from the drum and removed from the machine.
40214     MDH: Forced failure.
40216     MDH: Cannot enable/disable cycletest mode when machine not idle.
40217     MDH: Cannot enable/disable 'plateless' operation when machine not idle.
40228     MDH: Media Handler task aborted
40230     MDH: Invalid actuator timeout (must be non-zero)
40231     MDH: <motor name> stepper motor cannot search for a sensor [<I/O name>] if waiting is not specified
40237     MDH: <motor name> stepper motor recieved an invalid setup parameter
40238     MDH: <motor name> stepper motor has not started a command, cannot wait for it to complete
40239     MDH: Software Error. The error code contains the wrong number of parameters
40240     MDH: Fatal error
40242     MDH: Could not set the media on the drum
40243     MDH: <motor name> stepper motor did not reach the sensor it was searching for [<I/O name>]
40244     MDH: Stepper motor cannot search for a sensor that has been disabled [<I/O name>]
40245     MDH: Command cannot be cancelled
40246     MDH: Media released, remove media and use MEDIA REMOVED to continue
40247     MDH: Software error, external command returned an invalid state message
40248     MDH: Software error, external command returned an invalid message type
40249     MDH: Software error, external command returned an invalid user argument
40254     MDH: Media handler sequence attempted to use auto-retry on step that pointed to a different step
40257     MDH: Software error. Wrong or invalid argument supplied
40258     MDH: Could not find step '<Step description>' in sequence
40267     MDH: <Motor name> stepper motor unexpectedly hit the home sensor
40275     MDH: <Motor name> stepper motor unexpectedly hit the away sensor
40283     MDH: <Motor name> stepper motor failed to respond
40292     MDH: The Media Handler experienced an internal error, restart the device
40293     MDH: <motor name> stepper motor has not completed previous command
40294     MDH: <motor name> stepper motor sensor mask(s) are setup but motor is not setup to wait for completion
40295     MDH: Operation failed, but no error setup (device actuate)
40296     MDH: <motor name> stepper motor waited for <timeout in seconds> seconds, but setup command did not complete
40297     MDH: <sequence type> (<sequence id>) sequence is not available with these arguments
40298     MDH: <sequence type> (<sequence id>) sequence is not supported on this device
40302     MDH: No plates detected in bay <Bay number>
40625     MDH: Media being loaded has an invalid mainscan length, min=<Minimum mainscan length in mm> mm, max=<Maximum mainscan length in mm> mm
40626     MDH: Media being loaded has an invalid subscan length, min=<Minimum mainscan length in mm> mm, max=<Maximum mainscan length in mm> mm
40629     MDH: Media partially loaded on drum, use RELEASE then remove the media
40632     MDH: Media flyoff detected, please open panel and remove media
40635     MDH: Cannot execute command because the drum is moving
40636     MDH: Drum not at the expected position, position may have shifted because of outside interaction
40639     MDH: Could not find balancer arms, make sure that the tabs are blocking the sensors
40640     MDH: Fix angle for the balance too small for balancer arms, balancer arms cannot support specified media dimensions
40669     MDH: Media not detected on load ramp
40673     MDH: Balancer timeout: Failed to <Action> sensor. [<I/O name>]
40692     MDH: Engine is currently busy, cannot change drum state
40706     MDH: Media expected to be <ExpectedLength> mm, measured to be <MeasuredLength> mm on the <Side> side
40714     MDH: Could not calculate the inertia of the drum
40813     MDH: Invalid exit number (exit #<Exit number>) selected
41002     MDH: Use drum control buttons to unload media
41005     MDH: Press the drum vacuum button
41006     MDH: Tape down leading edge and use drum control buttons to move drum to trailing edge tape position
41007     MDH: Use drum control buttons to move drum to leading edge tape position
41008     MDH: Open the table
41009     MDH: Close the table
41010     MDH: Load media on table
41011     MDH: Could not lock the table because the table was not closed
41012     MDH: Verify media if fully on drum and close the load table
41014     MDH: Turn the drum brake override switch off
41015     MDH: Open front cover by pushing RELEASE button
41016     MDH: Close front cover
41017     MDH: Engage and lock the tailstock
41018     MDH: Unlock, disengage, and move tailstock to up position
41022     MDH: Move drumlift to up position
41023     MDH: Move drumlift to down position
41024     MDH: Media being loaded has an invalid thickness: Measured (<MeasuredThickness> um) - Expected (<ExpectedThickness> um)
41025     MDH: Continue with measured media thickness (<MeasuredThickness> um)?
41030     MDH: Press RESUME to reload media or EJECT to cancel current image
41031     MDH: Tape trailing edge of media and close the table
41032     MDH: Drum balancing in progress
41034     MDH: Media may be unloaded at this position if required
41035     MDH: Complete side taping and press the drum vacuum button
41036     MDH: Plate unloaded onto table, use drum control buttons to continue to either reload the plate or fully unload
41037     MDH: Use drum control buttons to move drum to media unload position or media further onto the load table
41038     MDH: Drum control buttons unavailable
41042     MDH: Drumlift lever disabled, RESUME to re-enable
41049     MDH: Unload the sleeve then engage and lock tailstock
41050     MDH: Move tailstock to fully disengaged position before moving drumlift up
41051     MDH: Override drum brake, unlock cams, and then move drumlift to up position
41053     MDH: One touch operation failed <OperationDescription>
41054     MDH: One touch operation aborted
41055     MDH: One touch load/unload cannot operate in device mode with front door closed
41056     MDH: One touch mode select switch must be in device mode
41057     MDH: Engage processor shaft onto arbor. Push sleeve onto shell and push lever forward to first detent
41058     MDH: Move lever forward to control sleeve load. When sleeve is loaded, push lever fully forward to complete load
41059     MDH: Engage processor shaft onto arbor and pull lever backward to first detent
41060     MDH: Move lever backward to control sleeve unload. Pull lever fully backward and hold to complete unload
41061     MDH: Disengage processor shaft from the arbor then engage and lock tailstock
41062     MDH: Production hub lever range <RangeIndex> settings incorrect. <Limit> <Relation> <Limit>
41064     MDH: Press flashing device button on pedestal to start
41065     MDH: Remove media from device manually and close the table
41068     MDH: Measured plate thickness of <Thickness> um is out of range of supported thicknesses
41071     MDH: Cannot unload sleeve media when drum is loaded. RESUME to clear device state
41072     MDH: Override drum brake, load/tape media onto drum manually, re-enable drum brake, and close the table
41073     MDH: Override drum brake, remove manually loaded media from drum, and press drum vacuum button when done
41074     MDH: Hoist not in down position. Move hoist to down position to continue
41075     MDH: Tailstock is not locked. Lock tailstock to continue
41076     MDH: Camlock or arborlock not acknowledged. Lock camlocks or arborlock and press the acknowledge button to continue
41077     MDH: Drum not exchanged for sheet mode. Ensure drum is mounted to continue
41078     MDH: Drum not exchanged for sleeve mode. Ensure arbor is mounted to continue
41079     MDH: Perform an exchange if required. Load device with selected media. Refer to operator's manual for more information
41080     MDH: An exchange was not properly completed. Restore either the drum or arbor to continue.
41500     OWB: Internal Error - 1-Wire-Bus response buffer became full
41501     OWB: OWB General Failure
41502     OWB: The 1-Wire-Bus appears to be shorted.
41503     OWB: An Alarm presence pulse was found on the 1-Wire-Bus.
41504     OWB: No node presence pulse was found on the 1-Wire-Bus.
41505     OWB: The 1-Wire-Bus adapter (DS1411) is not responding.
41506     OWB: Bad CRC received from a Node ID on the 1-Wire-Bus.
41507     OWB: Write Data failed to verify from a Node on the 1-Wire-Bus.
41514     OWB: No more Nodes on the 1-Wire-Bus.
41600     KEY: Dongle Not found. Imaging is disabled.
41601     KEY: Too many devices detected.
41602     KEY: Dongle not initialized
41603     KEY: Duplicate dongle detected
41604     KEY: Invalid dongle detected
41605     KEY: Invalid serial number detected
41606     KEY: Invalid feature requested
41607     KEY: Optional feature specified not found
41608     KEY: Optional feature table is full
41800     IBM: General Failure
41801     IBM: Invalid iButton Scanner data point handle
41802     IBM: Cannot write to an iButton handle that is a READ value
41803     IBM: Could not find the requested iButton handle
41804     IBM: iButton Manager (IBM) is not initialized
41805     IBM: The requested iButton handle is not available
42900     PST: POST: <Test Code> - <Test Description>
42901     PST: No response received from <Satellite Board>
42902     PST: Unknown satellite board (ID=<Satellite ID>) found
42903     PST: Invalid mode parameter in RCON command Get Post Result
42999     PST: Machine Electronics FAILED Power On Self-Tests
43001     DEB: Debris removal software error: <Software error>
43002     DEB: Particulate Only Collection (POC) debris removal is not enabled on this device
43003     DEB: Particulate and Chemical Collection (PACC) debris removal is not enabled on this device
43004     DEB: The air jet is enabled, but not turned on
43005     DEB: The blower is not turned on
43006     DEB: The flow rate is below the minimum required
43007     DEB: The cabinet has lost power
43008     DEB: The particulate filter is not present or upside down, the lid is not closed, or the data cable is disconnected
43009     DEB: The particulate filter is almost full. Please ensure a replacement filter is on hand
43010     DEB: The particulate filter is full. You must replace the particulate filter to continue imaging
43011     DEB: The debris collection nozzle is blocked
43012     DEB: The debris hose is disconnected
43013     DEB: There is a problem with one or more of the pressure sensors in the debris removal cabinet
43014     DEB: The debris hose is disconnected, the cabinet has lost power, or the cabinet lid is not latched properly
43015     DEB: There may be a partial blockage of the collection nozzle, or a leak, but the flow rate is still above minimum
43016     DEB: There is a partial blockage of the collection nozzle, or a leak, and the flow rate is below minimum
43017     DEB: The media being imaged releases potentially harmful emissions. See the Operator Manual for more information
43018     DEB: The debris removal chemical filter is not present
43019     DEB: The chemical filter has almost expired. Please ensure a replacement filter is on hand
43020     DEB: The chemical filter has expired. You must replace the chemical filter and reset the output device to continue imaging
43021     DEB: The chemical filter usage sensor is corrupt or the chemical filter was changed and the output device was not reset
43022     DEB: Unable to communicate with the chemical filter. See the Operator Manual for more information
43023     DEB: The chemical filter usage calculated is negative
43024     DEB: Unable to calibrate <Sensor Name> pressure sensor
43025     DEB: Unable to communicate with the chemical filter during initialization. See the Operator Manual for more information
43026     DEB: Timeout: the pressure sensor output failed to stabilize
43027     DEB: No debris removal options are enabled on this device
43028     DEB: There is a problem with the nozzle pressure sensor in the output device
43029     DEB: Command failed: cannot run more than one PACC option at a time
43030     DEB: Cannot start new debris option while another is in an error condition
43031     DEB: The chemical filter installed is not suitable for the selected media
43032     DEB: The particulate filter is almost full AND the chemical filter has almost expired
43033     DEB: Cannot setup ibutton: <IButton Parameter>
43034     DEB: Chemical filter iButton already has valid usage information, did not reprogram
43035     DEB: Conversion failed.
43301     CRG: software error
43302     CRG: Carriage initialization timed out <Initialization operation>
43303     CRG: Carriage is reserved, command ignored
43304     CRG: The current carriage command has been preempted
43305     CRG: Carriage Hardware Fault: <Description of the faulted hardware component>
43306     CRG: Requested carriage velocity too high, recommended max = <Recommended maximum carriage velocity> mm/sec
43307     CRG: Carriage Accel requires Ispeed, Mspeed or velocity in range +/- <Maximum carriage velocity using current acceleration value> mm/s
43308     CRG: Carriage travel limit (<Text string describing which limits signals are active as follows>) unexpectedly hit
43309     CRG: Carriage velocity exceeds register size
43310     CRG: Carriage has aborted plotting
43311     CRG: Carriage can not reach requested position
43312     CRG: Carriage Amplifier fault: <Text string describing specific amplifier fault>
43313     CRG: Carriage currently initializing
43314     CRG: Carriage not initialized
43500     DF1: internal memory allocation error - DF1 Driver
43501     DF1: failure to open to the URT Subsystem - DF1 Driver
43601     MOP: MOP Initialization failed
43602     MOP: Argument name not found or used token in place of argument
43603     MOP: MOP API() function can only be used with optional tokens
43604     MOP: Internal MOP firmware error
43605     MOP: Unregistered MOP commands or MOP commands registered twice
43606     MOP: An invalid MOP access level was selected
43701     ZAD: Could not read the Z-Drive parameters
43702     ZAD: Command not expected at this time
43703     ZAD: Internal firmware error
43704     ZAD: Command was aborted
43705     ZAD: Error sending SMC motor command
43706     ZAD: Zdrive stopped by external command
43707     ZAD: Zdrive not initialized, position is unknown
43708     ZAD: Zdrive motor could not be initialized, zdrive cannot be used
43709     ZAD: Zdrive is busy
43710     ZAD: Zdrive is busy trying to abort
43711     ZAD: Zdrive is busy trying to stop
43712     ZAD: Zdrive is in invalid state
43713     ZAD: Zdrive received an invalid message
43714     ZAD: Zdrive invalid internal structure
43715     ZAD: Zdrive received an invalid state message
43716     ZAD: Zdrive received an invalid message type
43717     ZAD: Zdrive received an invalid message code
43718     ZAD: Zdrive requires SMC version <SMC Version major>.<SMC Version minor>
43802     ZAC: Another z axis sequence is currently being processed
43803     ZAC: Internal: Invalid parameter passed to function
43804     ZAC: Internal: System resource unavailable
43805     ZAC: Focus Error value requested while focus out of range or saturated
43806     ZAC: Z Axis Focus routine aborted by monitor command
43807     ZAC: Media not found by Z axis, confirm dimensions
43808     ZAC: Media not found by Z axis, confirm dimensions
43809     ZAC: Head operation timed out
43810     ZAC: Media not found by Z axis due to head collision, confirm dimensions
43811     ZAC: Eccentric media surface: Probable cause out-of-round cylinder / bad mount
43900     CTP: CTP Engine Component is not present - internal firmware error
43904     CTP: Lost communication with the slave board
43905     CTP: Master/slave operation timed out
44101     DVC: Drum vacuum fatal error occurred
44102     DVC: Invalid command sent to drum vacuum subsystem
44103     DVC: Drum vacuum is in an invalid state
44104     DVC: Drum vacuum is not initialized
44105     DVC: Drum vacuum has encountered an error and must be turned off before it can be turned on again
44106     DVC: Drum vacuum already running, must be turned off before it can be turned on again
44107     DVC: Drum vacuum sensor gain not set
44108     DVC: Drum vacuum received an invalid message
44109     DVC: Drum vacuum command has an invalid callback
44110     DVC: Drum vacuum command hijacked, drum vacuum turned off
44111     DVC: Drum vacuum pressure is <current pressure in milli inches of HG> milliInHg, setpoint is <setpoint in milli inches of HG> milliInHg
44112     DVC: Drum vacuum is not on, cannot check status
44113     DVC: Drum vacuum is not on, cannot update
44114     DVC: Drum vacuum <setpoint in milli inches of HG> milliInHg setpoint is too high, limit is <limit in milli inches of HG> milliInHg
44115     DVC: Drum vacuum <setpoint in milli inches of HG> milliInHg setpoint not reached, current pressure is <current pressure in milli inches of HG> milliInHg
44116     DVC: Drum vacuum frequency <setpoint in milliHz> milliHz is too high, max is <maximum in milliHz> milliHz
44117     DVC: Drum vacuum pressure not stabilizing
44118     DVC: Drum vacuum has not been updated
44201     DTL: Non-head type message sent to DTL Driver
44202     DTL: DTL Driver unable to determine message type
44203     DTL: DTL Driver: invalid logical channel number
44204     DTL: DTL head communication sync lost
44205     DTL: DTL communication port not open
44206     DTL: Timeout attempting to close communication port
44207     DTL: DTL Server received a packet bigger than allowed
44208     DTL: DTL Server received a packet containing an illegal command
44209     DTL: DTL server or client failed to establish a TCP/IP connection
44210     DTL: TCP socket is shut down locally or remotely
44211     DTL: Internal error of TCP protocol
44212     DTL: TCP socket create failure
44213     DTL: TCP socket connect failure
44214     DTL: TCP protocol received an invalid packet
44215     DTL: TCP protocol link is not ready
44300     CEH: Error Code [<Error code>] <Error string>
44301     CEH: Warning Fault [<Error code>] <Error string>
44302     CEH: Fatal Fault [<Error code>] <Error string>
44303     CEH: The write laser request is in progress
44304     CEH: The stroke calibration is in progress
44305     CEH: The focus request is in progress
44306     CEH: The requested media is not supported by the exposure head
44307     CEH: An upgrade of the host firmware is recommended
44308     CEH: An upgrade of the exposure head firmware is recommended
44309     CEH: An upgrade of the host firmware is required
44310     CEH: An upgrade of the exposure head firmware is required
44311     CEH: The requested functionality is not supported by the exposure head
44401     BOS: BOS subsystem not initialized - cannot proceed.
44402     BOS: The requested update rate for the BOS subsystem is less than 50 ms
44403     BOS: Error creating BOS group: Output bit already used elsewhere
44404     BOS: Error creating BOS group: Too many outputs in group, max is 15
44405     BOS: BOS Handle specified is invalid, cannot process action
44406     BOS: New state for BOS group is invalid, cannot update group state.
44407     BOS: BOS has run out of empty groups and so cannot create a new one.
44408     BOS: BOS timed out trying to find a handle for a new group.
44500     EHI: The exposure head is offline
44501     EHI: The exposure head is being initialized
44502     EHI: The exposure head has failed
44503     EHI: The exposure head is in programming mode
44504     EHI: The exposure head has been disabled
44505     EHI: Head command transporter is not open
44506     EHI: Head command transporter failure
44507     EHI: The response / unsolicited packet is invalid
44508     EHI: The response / unsolicited packet length is invalid
44509     EHI: The response / unsolicited packet protocol is invalid
44510     EHI: The unsolicited packet is not supported
44511     EHI: The exposure head control mode is invalid
44512     EHI: The exposure head type is invalid
44513     EHI: The exposure head control mode transition is invalid
44514     EHI: The exposure head has unexpectedly reset
44515     EHI: The baud rate negotiation algorithm has failed
44516     EHI: The application protocol negotiation algorithm has failed
44517     EHI: The command packet is not supported
44518     EHI: The exposure head is not supported
44519     EHI: Baud rate negotiation is not supported by the exposure head
44520     EHI: Application protocol negotiation is not supported by the exposure head
44521     EHI: The error string cannot be determined; the exposure head type is unknown
44522     EHI: The error string could not be retrieved from the exposure head
44523     EHI: The functionality is not supported
44524     EHI: Monitor redirection is not supported
44525     EHI: A parameter is invalid
44526     EHI: EHI port closed before head commands complete
44527     EHI: Command response from exposure head took too long
44528     EHI: Response from head incorrectly sequenced
44529     EHI: Parameter load already in progress
44530     EHI: Specified parameter group unknown
44531     EHI: Changed parameter unknown in thermal head
44532     EHI: The monitor command requires the exposure head to be online
44533     EHI: The monitor command requires application protocol 0
44534     EHI: The monitor command requires a Thermal 1.0 or Thermal 1.7x exposure head
44535     EHI: The monitor command requires a Tfx or Thermal 2 exposure head
44536     EHI: The Thermal 1.0 or Thermal 1.7x exposure head was unable to learn focus
44537     EHI: Timeout waiting for the focus
44538     EHI: Timeout waiting for the write laser
44539     EHI: The firmware version of the exposure head is not supported
44540     EHI: Unexpected software failure
44541     EHI: Head Command Transaction Buffer Overflow
44542     EHI: Head Media Data Block format is unsupported
44543     EHI: Timeout during head redirection access attempt
44544     EHI: Parameter access buffer overrun attempted
44545     EHI: The redirected command to the head failed
44546     EHI: The Media Data Block is missing data
44547     EHI: The head has requested to be powered down
44600     MPI: Carrier not loaded or specified Proof Index is out of range
44601     MPI: Invalid proof type
44602     MPI: Invalid proof border types
44603     MPI: No more media supported
44604     MPI: Media Image Mode ID out of range: <MIMID>
44605     MPI: Media matching MIMID not found
44606     MPI: Corrupted internal value detected
44607     MPI: Internal firmware failure
44608     MPI: MPI subsystem not initialized.
44609     MPI: Exposure head not available.
44610     MPI: Media name is blank or invalid
44611     MPI: Head operation timed out
44612     MPI: Invalid or unrecognized Media Data Block
44613     MPI: Media index out of range: <Media index>
44614     MPI: Buffer overflow
44615     MPI: MIMID <MIMID> already in use by slot <Slot Number>
44800     EHI: no error
44801     EHI: temperature out of range
44802     EHI: value out of range
44803     EHI: missing laser on parameters
44804     EHI: attempted write blocked
44805     EHI: failure to write to memory
44806     EHI: unsupported message
44807     EHI: message length incorrect
44808     EHI: invalid control message
44809     EHI: operation was aborted
44832     EHI: no more room in mailbox
44833     EHI: ran out of buffers
44834     EHI: all retries failed on chnl 0
44835     EHI: all retries failed on chnl 1
44836     EHI: sync lost on chnl 0
44837     EHI: sync lost on chnl 1
44848     EHI: CONFIG register incorrect
44849     EHI: flash memory checksum error
44850     EHI: LCA won't init for reprogram
44851     EHI: LCA won't admit being loaded
44852     EHI: SRAM memory check failure
44896     EHI: software error
44897     EHI: LCA config unavailable
44898     EHI: LCA not found
44899     EHI: hardware timeout
44946     EHI: WLC PCB overheated, reset head
44947     EHI: Laser drive current limit
44948     EHI: Laser safety interlock is open
44949     EHI: DTD laser diode over temperature
44950     EHI: DTD laser diode over voltage
44951     EHI: DTD laser diode over current
44952     EHI: DTD +24V supply low
44953     EHI: DTD +24V supply high
44954     EHI: DTD +15V supply low
44955     EHI: DTD temperature sensor open circuit
44956     EHI: DTD software timeout
44957     EHI: DTD reset asserted
44958     EHI: DTD temperature below set point
44959     EHI: DTD temperature above set point
44960     EHI: shutter disabled
44961     EHI: reset detected
44962     EHI: laser disabled
44963     EHI: focus not initialized: Execute 'focus init'
44964     EHI: focus error detected at <Subscan location> mm <Relative location> while imaging, check plate for artifacts
44965     EHI: laser shutdown detected
44966     EHI: head case over temperature, <Case temperature> C
44967     EHI: head ambient over temperature, <Ambient temperature> C
44968     EHI: media <Media number> not found in HDM nvs subsystem
44969     EHI: crash detected, error code = 0x<Error code>
44970     EHI: Warning - head temperature high, <Case temperature> C
44971     EHI: SCORR out of range
44972     EHI: checksum error in <NVS subsystem> calibration block
44973     EHI: checksum error in <NVS subsystem> configuration block
44974     EHI: newline error, check drum encoder and LC-BP cable
44975     EHI: media thickness out of range
44976     EHI: EH-PHI cbl. (hotlink fault)
44977     EHI: LV 24V not in range (unipolar)
44978     EHI: LV 24V or High voltage fault
44979     EHI: LV Over temperature
44980     EHI: LV Too much stray light for beam balance
44981     EHI: LV Negative 12V fault (unipolar)
44982     EHI: LV Bias current fault (unipolar)
44983     EHI: Recalibration is on
44984     EHI: Recalibration fault
44985     EHI: checksum error in stroke correction download
44986     EHI: LV Not enough light for beam balance
44987     EHI: stroke clock frequency invalid, aborting download
44988     EHI: DTD status unstable
44989     EHI: Laser sampling disabled (wsample == 0)
44990     EHI: Beam position sampling disabled (bsample == 0)
44991     EHI: Focus sampling disabled (fsample == 0)
44992     EHI: Light level too low for Beam Pointing
44993     EHI: Timeout waiting for LASER OK
44994     EHI: Light valve high voltage fault
44995     EHI: LV Positive 12V fault (bipolar)
44996     EHI: Stroke Clock or Imaging signal fault, check LC-BP cable
44997     EHI: Focus sensor fails linearity test, check head position
44998     EHI: Laser safety loop has just been closed
44999     EHI: Laser safety loop has just opened
45000     EHI: Only the safety loop detected by the head has closed
45001     EHI: Only the safety loop detected by the laser has closed
45008     EHI: executive call tsk_create() failed
45009     EHI: all tasks suspended
45010     EHI: executive call mbx_create() failed
45011     EHI: executive call mbx_send() failed
45012     EHI: executive call buf_alloc() failed
45013     EHI: executive call tmr_create() failed
45014     EHI: Task received message that was not sent
45015     EHI: Task sending message owned by another task
45016     EHI: Task sending unreserved message
45017     EHI: message buffer request failed
45018     EHI: Reserved message in message pool
45019     EHI: Task releasing message owned by another task
45020     EHI: Task releasing unreserved message
45021     EHI: message buffer release failed
45022     EHI: Unexpected message in mailbox
45023     EHI: Command parameter error
45024     EHI: Laser beam positioning not stable yet
45025     EHI: LV serial communications TX timeout
45026     EHI: timeout waiting for A/D output
45027     EHI: LV LCA not initialized
45028     EHI: LV LCA not done
45029     EHI: LV serial communications RX timeout
45030     EHI: LV board not connected
45031     EHI: incorrect light level at start of edge detection - check if plate loaded is too large
45032     EHI: Unable to balance stroke to better than head bpmaxerr percent
45033     EHI: library call failed
45034     EHI: the thermal head requires an upgrade
45035     EHI: case temperature high alarm, <Case temperature> C
45036     EHI: case temperature high warning, <Case temperature> C
45037     EHI: case temperature low alarm, <Case temperature> C
45038     EHI: case temperature low warning, <Case temperature> C
45039     EHI: ambient temperature high alarm, <Ambient temperature> C
45040     EHI: ambient temperature high warning, <Ambient temperature> C
45041     EHI: case and ambient temperature normal
45042     EHI: shutdown of thermal head due to temperature or humidity alarm
45043     EHI: thermal head humidity alarm, <Humidity> percent
45044     EHI: unable to learn focus, change focus mode or shift plot
45045     EHI: unable to find exposure power, set to 0 W
45204     PRD: WARNING: The device is currently running in simulation mode - for testing purposes only!
45205     PRD: Invalid limit tag specified
45212     PRD: Drumlift hoist in up position
45232     PRD: Safety override switch is on, cannot plot with override on
45235     PRD: Safety loop is not enabled (<I/OName>)
45236     PRD: Head Input Fault: <Input bit description> (<Input bit name>) In Unexpected State
45238     PRD: Temperature conversion failed
45242     PRD: Chiller flow is too low (<bit description>)
45246     PRD: Cannot lock table when table not closed
45263     PRD: Component not available to set offline or online
45283     PRD: <Board name> (<Board ID>) <Relay name> relay contacts welded, replace board
46201     FWD: Empty firmware directory sector
46202     FWD: FWD Entry Not Found
46203     FWD: FWD handle is invalid
46204     FWD: FWD entry table integrity error
46205     FWD: Component ID is invalid
46206     FWD: Invalid function parameter
46207     FWD: Firmware directory entry table is full
46208     FWD: Invalid firmware directory entry or component check sum
46209     FWD: Directory table synchronization failure
46210     FWD: Directory table contains duplicated entries
46211     FWD: Directory table need to be validated
46212     FWD: End of directory table reached
46213     FWD: Firmware directory system is locked
46214     FWD: Failed to lock firmware directory system
46701     HIM: A parameter to an internal function is invalid
46702     HIM: Attempt to register too many notification callbacks
46703     HIM: Attempt to clear callback that was not previously established
46704     HIM: Head command currently in progress has been preempted
46705     HIM: The head programming operation could not be started
46706     HIM: Head programming state machine integrity violated
46707     HIM: File download state machine integrity violated
46708     HIM: No response from the head while downloading bootloader
46709     HIM: Protocol violation while downloading bootloader to the head
46710     HIM: Head does not support this version of bootloader
46711     HIM: No response from the head while programming
46712     HIM: Protocol violation while programming the head
46713     HIM: Head bootloader failed to program
46714     HIM: Serial port overflow while programming the head
46715     HIM: No data received from the workstation while programming the head
46716     HIM: 'S' expected (received <Received character>) at start of record <Line number> in S-record file
46717     HIM: Invalid record type found at record <Line number> in S-record file
46718     HIM: Invalid data byte <Invalid byte> found at offset <Record offset> of record <Line number> in S-record file
46719     HIM: Checksum failed on record <Line number> in S-record file
46720     HIM: Extra character(s) found at end of record <Line number> in S-record file
46721     HIM: Multiple head interface failures - check interface cable
46722     HIM: No head detected on fiber link - check cable and BOOTP server
46723     HIM: No head detected on serial link - check cable
46724     HIM: Thermal head FTP download file has an invalid checksum
46725     HIM: Thermal head FTP download file name is invalid
47807     MDH: <motor name> stepper motor did not reach or remain on the sensor it was searching for [<I/O name>]
47904     MDH: Slip sheet bin is full, empty slip sheet bin

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.