Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
16 Jul 2008: Procedure: Removing and installing the COM board on Magnus 400 configurations with image CD 1.14 More...
This procedure describes how to remove and install the COM board on Magnus 400 configurations with image CD 1.14.
Go to Parts replacement on the Procedures
page.
TechPlanet DVD Version 7 N.2—10 Jul 2008
30 Jun 2008: Troubleshooting: 0.15 plates intermittently load crookedly on Magnus 400 family semi-automatic platesetters More...
Incorrect plate loading parameters prevent 0.15
plates from reaching the registration pins and loading properly onto the
drum.
Go to Loading on the Troubleshooting
page.
25 Jun 2008: Troubleshooting: Hasp (F-speed key) error on Magnus 400 family platesetters More...
When starting the Magnus 400 Controller software, hasp
error messages appear.
Go to Startup on the Troubleshooting page.
25 Jun 2008: Troubleshooting: Paper bin task fails on platesetters with Magnus 400 Controller 1.02.392 or 1.04.393 More...
When using wide plates, the paper
bin task fails because the tweezers fail to pick up the plates.
Go to Paper disposal on the Troubleshooting page.
15 Jun 2008: Troubleshooting: Get fails when using smart edge detection on Magnus 400 family platesetters with Magnus 400 Controller 1.01.391 More...
Verify that the correct smart edge detection board is installed, start
the Magnus 400 Controller 1.01.391 with Update 3 software, and configure
the Communicator for SED Card parameter for COM6.
Go to Edge detection on the Troubleshooting page.
11 Jun 2008: Updated: Calibration test procedures and overview More...
The Lotem 400 FH, Magnus 400 LDA, and Magnus 400 II LDA calibration test procedures have been updated and are available for reference purposes.
A short overview, including anti-collision guidelines, is also available.
Go to Calibration tests under Calibration on the Procedures page.
03 Jun 2008: Troubleshooting: Activating Windows 2000 cache memory on Magnus 400 and Magnus 400 II family platesetters More...
If the Write cache enabled check box is not selected, the
cache memory is not saved.
Go to Performance on the Troubleshooting page.
28 May 2008: FCO 512-00492A: Improved power distribution board More...
FCO 512-00492A installs the improved power distribution board (PDB) to prevent board burn-out due to
continuous drum vacuum pump operation.
Go to the FCOs page.
04 May 2008: Troubleshooting: Laser diode failure on Magnus 400 More...
If a laser
diode failure occurs on a Magnus 400 platesetter, run diagnostics before you calibrate or splice any diodes.
Go to Exposing on the Troubleshooting
page.
04 May 2008: Procedure: Removing and installing the power distribution board More...
This procedure describes how to remove and install the power distribution board (PDB).
Go to Parts replacement on the Procedures page.
30 Apr 2008: Procedure: Removing and installing the leadscrew More...
This procedure describes how to remove and install the leadscrew.
Go to Parts replacement on the Procedures page.
28 Apr 2008: Troubleshooting: Magnus 400 Controller communication with MCE is slow More...
On Magnus 400 family configurations with disc image version 1.14, the Magnus
400 Controller software is slow to establish communication with the MCE device,
and once established, the Unauthenticated User icon appears in the Quick Launch
tray.
Go to Connectivity on the Troubleshooting
page.
03 Apr 2008: Technical bulletin: Optimizing the Width Start Image Area According to Plate Size on Magnus 400 and Magnus 400 II Family Platesetters More...
The difference in distance between the inner registration pin and the outer registration pin is 0.5 mm.
To ensure that your plate is properly aligned for plate exposure, adjust the Width Start Image Area parameter.
Go to Technical bulletins on the Reference page.
01 Apr 2008: Procedure: Removing and installing the drum motor More...
If the drum motor fails to rotate the drum, rotates the drum in the wrong direction, or is excessively noisy, you might need to replace the drum motor.
This procedure describes how to remove and install the drum motor.
Go to Parts replacement on the Procedures page.
28 Feb 2008: Magnus 400 Component Finder More...
Two versions of the Magnus 400 Component Finder are available on TechPlanet: a web-based version, which is a browser enabled, searchable database
containing all the Magnus 400 components, and a downloadable version.
Go to Tools on the Parts/tools page,
or Component finder on the Reference page.
26 Feb 2008: LDA drivers for Magnus 400 family and Magnus 400 II family platesetters More...
Two LDA drivers are available for Magnus 400 and Magnus 400 II platesetter configurations.
Go to Technical bulletins on the Reference page.
TechPlanet DVD Version 7 N.1—15 Feb 2008
11 Feb 2008: Troubleshooting: Intermittent stepper motor failure More...
When the ampere values of the black stepper motor are not calibrated correctly
on Magnus 400 and Magnus 400 Quantum platesetters, the stepper
motor fails intermittently.
Go to carriage on the Troubleshooting page.
07 Feb 2008: Maintenance kit part number updated More...
The part number for the Basic PM Kit for Fiberhead configurations with MCU has been promoted from 518-00173A to 518-00173B.
In addition to Lotem Fiberhead with MCU configurations, the updated part number is also relevant to the Magnus 400 with MCU and Magnus 400 II with MCU II configurations.
Go to the Parts/tools page.
01 Jan 2008: Procedure: Using the Magnus Output Devices Installation Report Tool More...
This procedure describes how to use the Magnus Output Devices Installation Report Tool.
The tool enables field engineers to provide installation feedback to Kodak.
After every installation, open the Magnus Output Devices Installation Report Tool and submit the report.
Go to the Installation
page.
18 Dec 2007: European compressors for Magnus 400 and Magnus 400 II platesetters More...
For platesetter installations in Europe, two European compressor configurations are available.
Go to the Installation page.
27 Nov 2007: Software update: Update 1 for Magnus 400 Controller 1.02.392 software More...
Update 1 supports improved paper-picking and paper disposal parameters on Magnus 400 platesetter configurations.
Go to the Downloads page.
27 Nov 2007: Release notes: Update 1 for Magnus 400 Controller 1.02.392 software More...
Update 1 supports improved paper-picking and paper disposal parameters on Magnus 400 platesetter configurations.
Go to the Reference page.
12 Nov 2007: FCO 512-00460A: One-piece load roller More...
FCO 512-00460A installs the improved one-piece load roller to eliminate roller marks on plates
during the loading process.
Go to the FCOs page.
03 Nov 2007: Procedure: Adjusting the drum vibration sensors More...
When the drum stops frequently rotating and vibration error messages appear, you need to
adjust the position of the drum vibration sensors.
Go to the Procedures page.
TechPlanet DVD Version 6 N.3—01 Nov 2007
10 Sep 2007: FCO 512-00450A: Kit FCO for Magnus 400 Conveyor More...
FCO 512-00450A installs an improved middle support guide and front cover bracket on the plate conveyor to
accommodate smaller plate sizes.
Go to the FCOs page.
30 Aug 2007: Troubleshooting: Exposure error appears on Magnus 400 LDA platesetters More...
When the values of the Default First Laser Number and Default
Last Laser Number parameters are changed and you start the exposure process,
an error
message appears.
Go to Exposing on the Troubleshooting
page.
19 Aug 2007: New features and parts on Magnus 400: Sensor wiring More...
The sensor wiring, which performs the same function as the upper and
lower enable detectors, enables the system to accurately locate the
drum position so that the grippers open at the correct loading and unloading
position.
Go to New features/parts on the Reference
page.
08 Jul 2007: Punch Conveyor Spare Parts More...
Spare parts are available for the punch conveyor configuration on Magnus 400 and Magnus 400 Quantum platesetters.
Go to Parts list
on the Parts/Tools
page.
03 Jul 2007: Troubleshooting: Plate collides with roller system when exiting punch More...
During the punch entry-to-drum entry stage of the loading sequence, the
edge of the plate collides with the support roller.
Go to Plates
on the Troubleshooting
page.
03 Jul 2007: Procedure: Drilling the drum on Magnus 400 More...
If fog appears on plates on either the head gripper side of the drum or the tail gripper side of the drum,
you need to drill additional holes in the drum.
Go to Other
procedures on the Procedures
page.
25 Jun 2007: Troubleshooting: Smart edge detection fails on Magnus 400 and Magnus 200 platesetters More...
When smart
edge detection fails, different error messages appear.
Go to Edge detection
on the Troubleshooting
page.
25 Jun 2007: Troubleshooting: Recurring “Datapath error” appears on Magnus 400 More...
A recurring
nondescript “Datapath error” appears in the Magnus 400 Controller
GUI, but does not include information about the error.
Go to Error/system messages
on the Troubleshooting
page.
24 Jun 2007: Troubleshooting: Plate skews during drum loading More...
During the plate-picking stage of the loading sequence, the vertical orientation
of one of the suction cups is skewed because a
suction cup leg bearing is loosely seated in the XY loading assembly bar.
Go to Loading
or Plates
on the Troubleshooting
page.
17 Jun 2007: Troubleshooting: Jobs abort in the queue after the plate exists the platesetter More...
If you change the Timeout For Shutdown UDRC mSec parameter to a value less
than 300,000, jobs
get stuck in the queue and the last job might abort.
Go to
Xpo on the Troubleshooting
page.
TechPlanet DVD Version 6 N.2—01 Jun 2007
12 Jun 2007: Repairing laser diodes on Magnus 200 and Magnus 400 platesetters More...
You can repair a faulty laser diode by splicing one optic fiber from the spare diode to the optic fiber of the faulty (original) diode. Find this item under Other procedures on the Procedures page.
28 May 2007: Troubleshooting: Problems on Magnus 400 after upgrading to Service Shell 2.6 More...
After installing FCO 512-00422A to upgrade from Kodak Service Shell 2.5 to version 2.6, Service Shell does not start. Find this item under Startup on the Troubleshooting page.
02 May 2007: Troubleshooting: RCON startup failure, drum in error state, and the Magnus 400 Controller software does not start on Magnus 400 and Magnus 200 platesetters More...
Warning: Do not change any IP address on the Magnus 400 and Magnus 200 platesetters. For more information about troubleshooting these problems, see Startup on the Troubleshooting page.
28 Apr 2007: FCO 512-00441A: Xpo 3.1.42 + Update 02 for Magnus 400/Lotem 400 More...
FCO 512-00441A for Xpo 3.1.42 corrects the problem where the Xpo software stops responding after platesetter failure and goes into a loop. Find this item on the FCOs page.
Note: It is recommended to install the update even if the problem did not occur.
16 Apr 2007: FCO 512-00422A Installing Creo Feature Licensing Server More...
FCO 512-00422A installs the Creo Feature Licensing Server on Magnus 400 and Magnus 400 Quantum platesetters. Find this item on the FCOs page.
27 Mar 2007: D-box Revision C for Magnus 400 More...
The new D-box Revision C replaces D-box Rev B. With D-box Rev C, you no longer need to use voltage selector keys or make power adjustments. For more information, see Ordering information on the Parts/tools page.
27 Mar 2007: Configuring punches on Magnus 400 More...
After you install punches on the platesetter, you need to configure them either from the registry or with the Kodak Magnus 400 Controller software. Find this item under Configuration on the Procedures page.
21 Mar 2007: Troubleshooting: Horizontal lines appear on Magnus 400 More...
When exposing images on Magnus 400 platesetters with a laser diode array (LDA) head, horizontal lines appear. Find the resolution under imaging on the Troubleshooting page.
20 Mar 2007: Creo Feature Licensing Server for Magnus 400 More...
The Creo Feature Licensing (CFL) Server is an integrated feature license management system that provides feature control management for multiple applications. Use the CLF server together with Service Shell 2.6 SP2. Find these items under Creo Feature Licensing Server on the Downloads page.
18 Mar 2007: Installing the center punch on Magnus 400 and Lotem 400 More...
The image between the plates will not be correctly registered if the plate height is not exactly the size it is supposed to be when using the image-to-edge edge detection system. To avoid this problem, cancel edge detection and perform image exposure according to image-to-punch, as described in “ Installing the center punch on Lotem 400 and Magnus 400 ”. Find this procedure under Parts replacement on the Procedures page.
12 Mar 2007: Registration pin configurations on Magnus 400 More...
The Kodak Magnus 400 platesetter supports three registration pin configurations. Find the correct registration pin configuration for your platesetter under Technical bulletins on the Reference page.
12 Mar 2007: Troubleshooting: Error 5733: LDR I/F fifo AEF in line More...
When the data path is corrupted, the error message “5733: LDR I/F fifo AEF in line” appears on Magnus 400. Find the resolution under error/system messages on the Troubleshooting page.
TechPlanet DVD Version 6 N.1—22 Feb 2007
22 Feb 2007: Troubleshooting: Single line data shifts appear on Magnus 400 More...
When a single line of data shifts on a Magnus 400 platesetter, replace either the internal PC cable or the cable that connects between the LMCE and LIF boards, as required. Find this item under imaging on the Troubleshooting page.
21 Feb 2007: Troubleshooting: Banding appears when using Staccato 25 or AM screening on Magnus 400 More...
When using Staccato 25 and AM screening on a Magnus 400 platesetter, banding appears on the exposed images. Find this item under imaging on the Troubleshooting page.
19 Feb 2007: Replacing the drum encoder on Magnus 400 More...
When the drum encoder cannot identify the drum position or sends the drum motor to the wrong drum position, you need to replace the drum encoder. Find this item under Parts replacement on the Procedures page.
18 Feb 2007: Upgrading from Magnus 400S speed to Magnus 400F speed More...
To upgrade the speed configuration on your platesetter from S speed (31 beams) to F speed (42 beams), follow the instructions in the upgrade procedure on the Procedures page.