Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


MCE Error Messages

Trendsetter AL specific Errors | Base Trendsetter Errors

See also

Errors specific to Trendsetter AL

This content is generated by scripts that pull information directly from Firmware Engineering's support site. The scripts were last run: 16 Jul 2008 17:30:34

Number Error Message
40302     MDH: No plates detected in bay <Bay number>
40345     MDH: Please remove plate(s) from the outer bay [<I/O name>]
40346     MDH: The plate stack is too high to deploy the outer bay arms
40401     MDH: Picker up/down timeout: Failed to <Action> sensor. [<I/O name>]
40402     MDH: Picker in/out timeout: Failed to <Action> sensor. [<I/O name>]
40403     MDH: Picker wrist timeout: Failed to <Action> sensor. [<I/O name>]
40404     MDH: Picker vacuum timeout: Failed to achieve vacuum threshold (<Threshold>) within <Timeout> ms (only reached <ActualValue>). [<I/O name>]
40405     MDH: Cannot move the picker, it has not been initialized
40406     MDH: Plate not detected on picker
40407     MDH: Please remove plate detected on picker
40408     MDH: Please close plate cover
40409     MDH: Cannot move picker <Direction> because <Obstruction>
40410     MDH: Plates are sticking together. Please open the plate cover and separate the plates. Press RESUME to continue.
40411     MDH: Timeout waiting for plate cover to be opened/closed. Command cancelled
40412     MDH: Device ready. Close plate cover to continue.
40413     MDH: Picker wrist sensor is not working
40414     MDH: Picker wrist cylinder is faulty
40415     MDH: Separator arm timeout: Failed to <Action> sensor. [<I/O name>]
40416     MDH: Cannot move separators <Direction> because <Obstruction>
40417     MDH: Please close plate cover, or put the preloader into position
40420     MDH: The Preloader is in a faulted state. Please check the Preloader display for more information
40421     MDH: The Preloader is not ready. It may be out of position, open, or not fully powered on
40423     MDH: The Preloader is not powered on. Please check the Preloader connections
40424     MDH: The Preloader is in the bay. Please check the Preloader display for more information
40425     MDH: The Preloader is not loading plates properly into the Trendsetter bay. Please check the Preloader display for more information
40426     MDH: No plates detected in the bay. The plate may not have been properly loaded by the Preloader
40801     MDH: Unload table up/down timeout: Failed to <Action> sensor. [<I/O name>]
40802     MDH: Unload table cups up/down timeout: Failed to <Action> sensor. [<I/O name>]
40803     MDH: Unload table vacuum timeout: Failed to achieve vacuum threshold (<Threshold>) within <Timeout> ms (only reached <ActualValue>). [<I/O name>]
40804     MDH: Cannot move the unload table, it has not been initialized
40805     MDH: Timeout waiting for plate to leave unload table
40806     MDH: Unload cups rotated, cannot move unload table cups
40807     MDH: Unload stepper motor not in safe position to rotate cups
40809     MDH: Please remove plate detected on unload table [<I/O name>]
40810     MDH: Rotator timeout: Failed to <Action> sensor. [<I/O name>]
40811     MDH: Unable to pull media out of engine. Media still detected at entry sensor [<I/O name>]
40812     MDH: Media not detected at unload table entry [<I/O name>]
40814     MDH: The processor is not ready to accept plates
40815     MDH: The processor is in a faulted state
40816     MDH: The processor is still busy with the previous plate, so is unable to accept another

Base Trendsetter Errors

This content is generated by scripts that pull information directly from Firmware Engineering's support site. The scripts were last run: 16 Jul 2008 17:30:30

Number Error Message
33256     BFD: Not in download state
33257     BFD: Firmware already in download mode
33258     BFD: Binary file download not complete
33259     BFD: Invalid download handle
33260     BFD: Binary File Header bytes were not zero
33261     BFD: Binary File Illegal Tag value(s) found
33262     BFD: Unknown download type
33263     BFD: unknown destination type specified
33264     BFD: Bad checksum calculated
33265     BFD: DOWNLOAD START message received, but not in IDLE state
33266     BFD: CPU reset type equals boot level
33267     BFD: Unknown Flash Manufacturer
33268     BFD: Unknown Flash Device or Failure Identifying Flash Device
33269     BFD: Failure writing flash
33270     BFD: Failure writing FW Dir entry for BBR Code
33271     BFD: Failure writing FW Dir entry for Xilinx
33273     BFD: No firmware directory entries available
33274     BFD: Error code not used
33276     BFD: Binary Upload data is exhausted
33277     BFD: Failure writing FW Dir entry for Overwriting data
33501     MSG: Message not reserved
33502     MSG: Invalid argument list
33503     MSG: Incorrect message type
33504     MSG: Incorrect message group
33505     MSG: Command queue is empty
33506     MSG: Timeout waiting on command queue
33507     MSG: String queue is empty
33508     MSG: Timeout waiting on string queue
33509     MSG: Message not released
33510     MSG: No messages in pool remaining
33511     MSG: Timeout waiting for message response
33512     MSG: Maximum head message is 31 bytes
33513     MSG: Failure Sending String Message - Queue Full
33514     MSG: No strings in pool remaining
33516     MSG: Message tracing is disabled
33517     MSG: Zero message trace buffers are allocated
33518     MSG: Internal firmware error
33519     MSG: Command code is filtered and not logged into trace buffer
33520     MSG: Message tracing is not disabled, cannot perform requested action
33521     MSG: Reached the end of the message trace buffer list
33522     MSG: No more free message trace filter entries
33523     MSG: A trace filter with the specified command code exists
33524     MSG: Command code not in trace filter list
33600     STG: Storage Key was not found
33601     STG: Storage Key data block is the wrong size
33602     STG: Storage medium is corrupt
33603     STG: Storage medium is full
33604     STG: More than one type of non-volatile storage medium specified
33605     STG: Invalid Subsystem Number specified for Key
33606     STG: Invalid Private Key Number specified for Key
33607     STG: End of NVS storage found
33608     STG: Storage Medium was recovered from backup
33609     STG: Access to STG Subsystem was Blocked
33610     STG: Invalid function parameter passed to an STG API function
33611     STG: Duplicate Key(s) present in NVS
33612     STG: The type of NVS specified does not exist in this product.
33613     STG: Attempted to write past the end of a STG RAM search table
33614     STG: The specified configuration code is invalid
33615     STG: The specified Nvs medium is not supported by the called function
33616     STG: Configuration failed
33617     STG: Storage medium is not initialized, it cannot be used
33618     STG: Storage medium is corrupt, it cannot be used
33619     STG: Storage medium is corrupt - key data checksum failed
33620     STG: Storage medium is corrupt - key storage control block checksum failed
33621     STG: Storage medium is corrupt - initialized values not set
33622     STG: Invalid storage partition
33623     STG: Invalid storage granularity
33624     STG: Cannot recover NVS medium, only one partition available
33700     MON: Diagnostic NT pipe to SVCHOST is not created
33701     MON: undefined error for monitor command
33702     MON: Failed to create a line editor component
33703     MON: The line editor has disabled forwarding to the terminal
33900     ERR: Description not found
33901     ERR: Too many error groups defined
33903     ERR: No error descriptor partitions left
33904     ERR: Test: <test string pointer> <test decimal value 16-bit integer> <test string pointer> <test pseudo float value (32-bit integer> <test string pointer> <test long 32-bit unsigned integer> <test string pointer> <test 16-bit hexadecimal value>
33905     ERR: Error group is invalid
33906     ERR: Error parameter overflow
33907     ERR: Firmware integrity failure
33908     ERR: Parameterized error table is full, all indexes are reserved
33909     ERR: Error buffer has overrun
33910     ERR: Error buffer is invalid
34000     PRM: Invalid function parameter(s) sent into API function
34001     PRM: Invalid parameter group identifier
34002     PRM: Duplicate registration of parameter group table
34003     PRM: Invalid parameter group table
34004     PRM: Duplicate parameter key found
34005     PRM: Invalid parameter key
34006     PRM: The search is complete
34007     PRM: The buffer size specified does not match buffer size for NVS parameter key
34008     PRM: The specified group description has not been found
34009     PRM: The parameter has not been found
34010     PRM: The parameter copy index is invalid
34011     PRM: The parameter element index is invalid
34012     PRM: The parameter syntax is invalid
34013     PRM: The parameter range is invalid (name="<Name of offending parameter>" key=<Key of offending parameter>)
34014     PRM: The string parameter syntax is not supported
34015     PRM: The string parameter length is invalid
34016     PRM: Unexpected software failure
34017     PRM: The functionality has not been implemented
34018     PRM: The PRM command is in progress
34019     PRM: No parameter table was registered for this group
34020     PRM: A zero is sent as the DataLength function parameter
34021     PRM: The PRM internal data buffer size is too small
34022     PRM: No more available overflow system table entries
34023     PRM: The group descriptions are inconsistent
34024     PRM: The NVS system table is corrupt
34025     PRM: NVS medium is corrupt
34026     PRM: STG subsystem General failure
34027     PRM: The NVS medium is full
34028     PRM: A STG key already exist with a different data block size
34029     PRM: Parameter key not found in NVS
34030     PRM: No default is associated with parameter
34031     PRM: No NVS is detected
34032     PRM: Parameter subsystem is not initialized
34033     PRM: Cannot modify parameter, not in configuration mode
34034     PRM: Cannot modify parameter, not in media mode
34035     PRM: The specified configuration code is invalid
34036     PRM: Configuration failed.
34037     PRM: Command cancelled
34038     PRM: This parameter is read-only
34039     PRM: Restricted parameter, insufficient access level
34040     PRM: This parameter is not accessible from the diagnostic monitor
34041     PRM: Parameter '<Group name><Index reference> <Short name><Element name>' changed from <Original value> to <New value> <Units>
34101     UTL: no saved records in history table
34102     UTL: invalid parameter
34103     UTL: pipe handle is invalid
34104     UTL: pipe is now full
34105     UTL: pipe is now empty
34106     UTL: data pipe could not be created
34107     UTL: data pipe could not be deleted
34108     UTL: Reached the end of a linear link list
34109     UTL: Memory Allocation Failure
34110     UTL: The pipe information has not registered
34111     UTL: Pipe is opened
34112     UTL: Connecting NT pipe
34113     UTL: Pipe not connected, cannot retrieve pipe name
34114     UTL: Failed to create and connect NT Pipe
34115     UTL: The destination pipe id is invalid
34116     UTL: The source pipe id is invalid
34117     UTL: The buffer to hold PipeName is too small
34118     UTL: Failed to read from NT pipe
34119     UTL: Sending too much data through an NT pipe
34120     UTL: Cannot disable interrupts when performing link list index search
34121     UTL: Conversion failed, software error
34122     UTL: No data is ready in the specified queue
34123     UTL: Cannot read from the board's IIC port
34124     UTL: Cannot write to the board's IIC port
34125     UTL: Fixed-size queue full
34126     UTL: Fixed-size queue empty
34127     UTL: Invalid format type for conversion
34128     UTL: Invalid engineering units for conversion
34129     UTL: Attempted to register too many override function tables
34130     UTL: Attempted to override the same function more than once
34131     UTL: Cannot override function because function cannot be found
34132     UTL: Cannot override function because override table not registered
34133     UTL: Attempt to register override table or override function after system initialization
34200     BCM: invalid port ID specified
34201     BCM: internal buffer space full
34202     BCM: timeout waiting for ACK
34203     BCM: general failure
34204     BCM: internal buffers exhausted
34205     BCM: HDLC CRC receiver error
34206     BCM: failure to create WIN32 thread
34207     BCM: client receive buffer too small
34208     BCM: received HDLC pkt not for us
34209     BCM: port is in 'Raw' mode
34210     BCM: can't send, no Carrier Detect
34211     BCM: timer thread create failure
34212     BCM: out of virtual connection buffers
34213     BCM: virtual connection was lost
34214     BCM: no more internal HDLC buffers
34215     BCM: transmit timeout multiplex error
34216     BCM: no multiplex communications occuring
34217     BCM: The BCM_PORT is not of type NT Pipe
34218     BCM: Invalid function parameter detected
34219     BCM: The pipe information has not registered
34220     BCM: Pipe is opened
34221     BCM: Connecting NT pipe
34222     BCM: Pipe not connected, cannot retrieve pipe name
34223     BCM: Failed to create and connect NT Pipe
34224     BCM: The destination pipe id is invalid
34225     BCM: The source pipe id is invalid
34226     BCM: The buffer to hold PipeName is too small
34227     BCM: Failed to read from NT pipe
34228     BCM: The specified BCM port is not opened
34229     BCM: Sending too much data through an NT pipe
34230     BCM: Baud Rate specified is too high
34231     BCM: Invalid Baud rate
34232     BCM: Transaction List Underflow
34233     BCM: HDLC Address Invalid or Unknown
34234     BCM: DOP Address Invalid or Unknown
34235     BCM: DNE-ICE Auto ID failure
34236     BCM: DNE-ICE Communication setup failure
34237     BCM: DNE-ICE Communication shutdown failure
34238     BCM: DNE-ICE connection failure
34239     BCM: DNE: receive timout failure on ICE data
34240     BCM: Transmission Cancelled
34241     BCM: Can't open W32 serial Port
34242     BCM: Can't initialize comm port buffers in Win32
34243     BCM: Access attempted to unsupported port in Win32
34244     BCM: Error while closing port
34245     BCM: Error while writing to port
34301     DPC: undefined pattern number
34302     DPC: close of closed scan
34303     DPC: close of un-open scan
34304     DPC: write to undefined scan
34305     DPC: call with NULL pattern struct
34306     DPC: Too many cells in pattern
34307     DPC: Pattern write call error
34308     DPC: write to un-opened scan
34309     DPC: write to closed scan
34310     DPC: open of NULL scan
34311     DPC: memory overflow
34312     DPC: too many scans
34313     DPC: timed out waiting for stripe to complete
34320     DPC: SCSI Driver Error, line <Line Number>
34321     DPC: SCSI driver error, invalid initiator
34322     DPC: SCSI asynchronous transfer requested, line <Line Number>
34323     DPC: SCSI parity error detected
34324     DPC: SCSI bus reset detected
34331     DPC: orthog slope smaller than minimum, check plate rotation
34332     DPC: orthog slope larger than max, check plate rotation
34333     DPC: OCCT SDRAM Test fail - Address = <Address>, Write data = <Write data>, Read data = <Read data>
34334     DPC: SDRAM module was not detected
34335     DPC: RIP resolution is invalid
34336     DPC: Pixels per stroke is invalid
34337     DPC: Subscan duplicate is invalid
34338     DPC: Mainscan duplicate is invalid
34339     DPC: Drum diameter is invalid
34340     DPC: Mainscan length is invalid
34341     DPC: Mainscan length is not a multiple of 32
34342     DPC: Pixels per stroke is not a multiple of 8
34343     DPC: DPC subsystem received unknown command message
34344     DPC: Stroke width not a multiple of subscan replication
34345     DPC: Reserved Error Code 1
34346     DPC: Reserved Error Code 1
34350     DPC: Data transfer already in progress
34351     DPC: Data transfer not in progress
34352     DPC: memory test not defined
34353     DPC: memory test failed at address
34354     DPC: too much data has been received
34355     DPC: too little data has been received
34356     DPC: Data channel not detected
34357     DPC: Datapath operation was preempted
34358     DPC: Image padding limit was exceeded
34359     DPC: No blank regions available for use
34360     DPC: No blank regions currently being used
34361     DPC: Invalid OCCT pointer send to datapath
34800     RIF: Image property parameter not found in list
34801     RIF: Image property list is invalid
34802     RIF: Image property type is invalid
34803     RIF: Message type is invalid
34805     RIF: Cannot merge image property lists
34810     RIF: Received invalid command code from workstation
34811     RIF: Received invalid parameter from workstation
34812     RIF: Command code received from workstation is not supported
34813     RIF: Received non-zero value in reserved field from workstation
34820     RIF: No more resolutions supported
34821     RIF: Resolution mode not defined
34822     RIF: Invalid resolution specified
34823     RIF: No more media supported
34855     RIF: Too many timestamps in timing loop-back packet
34856     RIF: Cannot timestamp a non timing loop-back packet
34857     RIF: Signifies that the packet represents a timing loop-back
34858     RIF: The input function parameter is incorrect
34900     RTL: failure
34901     RTL: no free transactions
34902     RTL: no match
34903     RTL: full
34904     RTL: addressing conflict
34905     RTL: no route found
34906     RTL: timeout
34907     RTL: port not opened
34908     RTL: NT COM port or pipe conflict
34909     RTL: Invalid Source Id String
34910     RTL: Invalid Destination Id String
34911     RTL: Cannot determine which DNE instance to connect to
34912     RTL: RTL transaction has already been freed
34913     RTL: No Communications to Target Device
34914     RTL: Route buffer is reserved by non-streaming messages
34915     RTL: The indexed RTL transaction is invalid
34916     RTL: Invalid CDI communication profile
34917     RTL: BCM port cannot be opened
34918     RTL: Linked List Protection Semaphore Fault
34919     RTL: Transaction flushed from RTL list
35702     PRD: unable to find subsystem name
35703     PRD: unable to find specified record
35706     PRD: unable to find specified subsystem number
35707     PRD: called function is not applicable for this product
35708     PRD: version information has already been registered
35709     PRD: version information has not been registered yet
35710     PRD: The run-time option specified does not exist
35711     PRD: Could not save the run-time option setting to NVS
35712     PRD: Flyoff occurred, remove media
35713     PRD: Flyoff sensor blocked, check machine for loose media, or check flyoff sensor
35714     PRD: Roller down, cannot move nor spin the drum
35718     PRD: Trailing edge backbone is down, cannot move or spin the drum
35720     PRD: Safety sense is not on, check doors and emergency off switch
35722     PRD: Media partially loaded on drum, cannot move nor spin drum
35724     PRD: Emergency stop switch is on
35733     PRD: Front panel is open, check front panel
35735     PRD: Back panel not detected, check back panel
35738     PRD: Cannot unlock doors if the drum is spinning
35741     PRD: Invalid Temperature Reading Attempted
35743     PRD: Invalid NVS key in callback
35744     PRD: The write laser could not be turned on because the safe line is not high
35745     PRD: The write laser relay did not activate as asked, it may be welded
35746     PRD: The drum amp relay did not activate as asked, it may be welded
35747     PRD: The main power relay did not activate as asked, it may be welded
35748     PRD: System Presence Fault: <Presence detect bit description> (<Presence detect bit name>) Not Detected
35749     PRD: System Input Fault: <Input bit description> (<Input bit name>) In Unexpected State
35750     PRD: System Output Fault: <Output bit description> (<Output bit name>) In Unexpected State
35751     PRD: System Range Fault: <Analog bit description> (<Analog bit name>) Out Of Range: Low=<Low range limit>, High=<High range limit>, Reading=<Current value>
35752     PRD: System Range Warning: <Analog bit description> (<Analog bit name>) Out Of Range: Low=<Low range limit>, High=<High range limit>, Reading=<Current value>
35756     PRD: Drum is spinning when a stationary drum is expected
35757     PRD: Hardware can't generate requested tach simulation velocity
35758     PRD: Leading edge backbone is down, cannot move the drum
35766     PRD: Invalid model configuration specified
35767     PRD: Ramp is in near the drum, cannot spin the drum
35772     PRD: System Pressure Out of Range: Reading=<Low range limit>, Low=<High range limit>, High=<Current value> (<Analog group name>)
35773     PRD: Top panels not detected, check top panels
35774     PRD: Top door is open, check top door
35775     PRD: Fanbox panel is not detected, check fanbox panel
35776     PRD: Invalid safety array entry specified
35777     PRD: Fatal error triggered
35778     PRD: Invalid callback
35779     PRD: User issued an abort, use 'abort clear' to clear the abort
35780     PRD: <Group name> Presence Fault: <Presence detect bit description> (<Presence detect bit name>) Not Detected
35781     PRD: <Group name> Input Fault: <Input bit description> (<Input bit name>) In Unexpected State
35782     PRD: <Group name> Output Fault: <Output bit description> (<Output bit name>) In Unexpected State
35783     PRD: <Group name> Range Fault: <Analog bit description> (<Analog bit name>) Out Of Range: Reading=<Current value>, Low=<Low range limit>, High=<High range limit>
35784     PRD: <Group name> Range Warning: <Analog bit description> (<Analog bit name>) Out Of Range: Reading=<Current value>, Low=<Low range limit>, High=<High range limit>
35785     PRD: <Group name>: All faults cleared
35786     PRD: Front panel is unlocked
35789     PRD: Media detected on the load ramp, cannot spin drum. Please remove media from the ramp
35790     PRD: Model code is invalid or unavailable
35791     PRD: Limit tag is not specified in the limit table
35792     PRD: Invalid optional value found. Limit tag [<Limit Tag>]. Value <Optional Value>.
35793     PRD: <Limit description> is <Limit value> <Unit>. <Parameter> <Unit> exceeds the limit.
35794     PRD: <Limit description> is <Limit value> <Unit>. <Parameter> <Unit> is lower than the minimum.
35795     PRD: <Limit description> must be <Limit State>.
35796     PRD: <Limit description> do not contain option flag <Option flag>. Cannot enable the option.
35797     PRD: <Limit description> is <Limit value> <Unit>. <Parameter> <Unit> is not equal to the limit.
35798     PRD: Key switch is on, drum speed limited to <Drum Speed> RPM
35800     _376: reset induced by software watchdog
35801     _376: reset induced by halt monitor
35802     _376: reset induced by RESET opcode
35803     _376: reset cause unknown
35804     _376: reset triggered by crash dump handler
36001     VBS: specified subsystem number is not registered
36002     VBS: specified output device is not applicable for this product
36200     URT: invalid serial port ID specified
36201     URT: serial port not opened yet
36202     URT: pipe access failed; pipe may be full (TX) or empty (RX)
36203     URT: illegal option specified
36204     URT: UART disabled
36501     BRD: Internal Error - Failed to create a Nucleus PLUS Timer
36502     BRD: Internal Error - Failed to control a Nucleus PLUS Timer
36503     BRD: Internal Error - Failed to Reset a Nucleus PLUS Timer
36504     BRD: Flash Driver code does not support this command primitive
36505     BRD: Flash Driver code has failed to program flash memory
36506     BRD: Flash Driver code has failed to erase a flash sector
36507     BRD: Insufficient memory to hold assembler flash driver routines
36508     BRD: The flash memory write operation failed to verify
36509     BRD: The address specified does not point to flash memory
36510     BRD: No Xilinx (LCA) was found in flash memory
36511     BRD: Undefined error
36512     BRD: Undefined error
36513     BRD: Board temperature sensor initialization failed
36514     BRD: No Overwriting pattern file (OVWR) was found in flash memory
36800     HLT: DNE not initialized (set DNE init 1)
36801     HLT: Invalid Parameters Sent to HLT Function
36802     HLT: Requested element is not registered
36803     HLT: Requested subsystem is not registered
36804     HLT: Internal HLT Subsystem Error
36805     HLT: A Subsystem has timed out
36806     HLT: Subsystem reported with unrecoverable error
36807     HLT: No cable detected between DNE and ICE
36808     HLT: BCM comm. between DNE and ICE has stopped
36809     HLT: The specified print unit is currently offline
36810     HLT: No Subsystem has reported in yet
36811     HLT: The system/subsystem is starting up
36812     HLT: Subsystem shutdown is currently taking place
36813     HLT: HLT subsystem has not initialized
36814     HLT: Workstation is not detected
36815     HLT: Feature is not available yet
36816     HLT: Firmware resource is low
36817     HLT: Print unit is online, connection checking not done
36818     HLT: SCSI Disk has errors
36819     HLT: SCSI disk not detected
36820     HLT: End of list detected
36821     HLT: Board temperature is above threshold
36822     HLT: Board temperature is above maximum limit
36900     MCE: Insufficient Heap Memory - required for DF1 serial drivers
36901     MCE: WMD Subsystem RCON Incoming Command Register Failure
36902     MCE: SDRAM Operation Failure
37420     PHS: TH2 error [<error code>] <error string>
37701     DRS: software error
37702     DRS: Drum operation timed out
37703     DRS: Drum is reserved, command ignored
37704     DRS: Overflow in internal drum calculation
37705     DRS: Tach simulator preventing drum servo control
37706     DRS: The current drum command has been preempted
37707     DRS: Drum servo control missing interrupts
37708     DRS: Specified drum velocity out of range
37709     DRS: Drum Hardware Missing <Description of the faulted hardware component>
37710     DRS: Drum Position Counter Overflow
37711     DRS: Specified Drum Torque out of range
37712     DRS: Drum Position Not Settling
37713     DRS: Drum Velocity Exceeded 100 Rpm in Torque mode
37714     DRS: Drum Velocity Error Exceeded
37715     DRS: Drum can't move to position at zero velocity
37716     DRS: Drum failed to reach position
37717     DRS: Number of allowable drum callbacks exceeded
37718     DRS: Drum target velocity invalid for PLL calculations
37719     DRS: Drum parameter patch range error: <Name of the drum NVS parameter that can not be patched because>
37720     DRS: Drum command passed an invalid pointer parameter
37721     DRS: Drum cannot use an encoder resolution of 0
37722     DRS: Drum can't stop at position when not moving
37723     DRS: Operation blocked while drum is freewheeling
37801     LCA: Xilinx LCA program failed
37802     LCA: Xilinx LCA file not found
37803     LCA: Xilinx LCA file checksum error
37804     LCA: LCA interrupt failed to register callback properly
37805     LCA: Feature not supported by the Xilinx firmware
37806     LCA: Invalid Latch ID specified
37807     LCA: Xilinx configuration failed
37808     LCA: SDRAM operation failed
37809     LCA: Overwriting pattern verification failed
37810     LCA: Invalid Overwriting Pattern detected
37811     LCA: Hardware can't generate requested tach simulation velocity
37812     LCA: <Feature> requires at least Xilinx v<Major version number>.<Minor version number>, current Xilinx is v<Major version number2>.<Minor version number2>
37813     LCA: Overwriting pattern <PatternID> is not licensed on this device
38101     MPC: Plot has been aborted
38102     MPC: Plot Mode is out of range or not valid
38104     MPC: Not configured for <Mainscan resolution> by <Subscan resolution> DPI resolution
38105     MPC: Startscan delay <Startscan delay> sub-pixels must be at least zero
38106     MPC: Total startscan delay <Startscan delay> sub-pixels is too large
38107     MPC: Mainscan image size <Mainscan image size> pixels too large, maximum is <Maximum image size> pixels
38108     MPC: Could not find edge of media after <Search attempts> attempts
38109     MPC: Head not configured for '<Media name>/<Media colour>/' media
38110     MPC: The carriage start position <Carriage start position> mm is beyond the home tab
38111     MPC: Timeout waiting for image data
38113     MPC: No resolution modes configured
38115     MPC: Invalid plot parameter ('<Parameter name>' = <Parameter value>)
38116     MPC: No valid edge found, check edge detect strip
38117     MPC: Internal: Invalid parameter passed to function
38118     MPC: Internal: System resource unavailable
38119     MPC: Midpoint position <Midpoint position> um too small for subscan media size
38120     MPC: Phase Lock Loop losing lock
38121     MPC: Debris removal not running as expected
38122     MPC: The '<Sequence name>' sequence is currently being processed
38123     MPC: The Phase Lock Loop could not be started
38124     MPC: The Phase Lock Loop cannot accommodate <Mainscan resolution> DPI
38125     MPC: The drum speed is too high for imaging, maximum is <Maximum drum speed> RPM
38126     MPC: The Xilinx firmware must be upgraded
38127     MPC: Mainscan image size <Mainscan image size> pixels must equal gapless drum circumference <Drum circumference> pixels
38128     MPC: Mainscan shift <Mainscan image shift> um larger than gapless drum circumference
38129     MPC: The specified sequence is not supported
38130     MPC: The pattern stroke width (<Pattern stroke width>) must equal the head (<Head stroke width>)
38131     MPC: Registration pins <First pin> and <Second pin> are configured incorrectly
38132     MPC: Media not on <Registration pin> registration pin
38134     MPC: Multiple plates detected on drum
38136     MPC: Subscan output resolution of <Subscan output resolution> DPI must equal head resolution
38138     MPC: Invalid media stack identifier <Media Stack Identifier> specified
38139     MPC: Cancel ignored, no sequence in progress
38142     MPC: Subscan image size <Subscan image size> pixels too large, maximum is <Maximum image size> pixels
38143     MPC: Internal: Expected plot sequence is not active
38144     MPC: The carriage end position <End position> mm is beyond the maximum travel distance <Maximum carriage travel> mm
38145     MPC: The media is sensitive to retraces and one or more retraces occurred
38146     MPC: Forced failure
38147     MPC: Head is not yet initialized
38148     MPC: Xilinx version <Current major version>.<Current minor version> is invalid, must be at least <Minimum required major version>.<Minimum required minor version>
38149     MPC: The head model installed is incompatible with this machine
38150     MPC: Image data sent to the head was possibly corrupted. Check plate for artifacts
38151     MPC: Invalid media type (<Media type>) for this operation
38152     MPC: Total amount of clamp shadow is too large
38153     MPC: Slave head resolution: <Head resolution on the slave board> DPI does not match with the one on the master: <Head resolution on the master board> DPI
38154     MPC: Slave head swath width: <Head swath width on the slave board> does not match with the one on the master: <Head swath width on the master board>
38155     MPC: Overwriting not allowed with pixel replication
38158     MPC: Timed out waiting for plot engine to initialize
38159     MPC: Communication failed between master and slave MCE boards
38161     MPC: The Phase Lock Loop did not stabilize
38164     MPC: Not configured for <Subscan resolution> DPI subscan resolution
38165     MPC: Variable mainscan resolution is not supported
38166     MPC: Carriage position is wrong - carriage has probably stalled
38167     MPC: <Head name> image is outside of the head's range (position <The position that triggered the error> um)
38171     MPC: Raster image data received from workstation was possibly corrupted. Check plate for artifacts
38172     MPC: Timed out waiting for raster image data CRC from workstation
38173     MPC: All heads are currently disabled
38176     MPC: Swath width is invalid, extra scanlines <Extra scanlines for current media> >= stroke width <Head stroke width>
38177     MPC: Media subscan size <Media Subscan Size> um is too long for registration pin configuration
38180     MPC: Slave error buffer overflow, unable to read slave error
38181     MPC: Plotting speed <Calculated carriage speed> mm/sec (<Pixels advanced per drum rotation> PPR at <Drum speed> RPM) exceeds licensed limit of <Carriage speed limit>
38183     MPC: Drum speed <Target drum speed> is too fast for <Target resolution> DPI resolution, maximum is <Maximum drum speed> RPM
38184     MPC: The media type '<Media name>' is not currently allowed on this device
38185     MPC: Current stroke width of <Current Stroke Width> is greater than allowed maximum of <Maximum Licensed Stroke Width>
38186     MPC: Workstation Fault [<Image error code>] <Image error text>
38188     MPC: '<Sequence table>', sequence '<Sequence>' (<Sequence address>), failure action <Failure action> not found
38189     MPC: ExtraScanlines and StrokeWidth set incorrectly for the yaw test pattern
38190     MPC: Phase Lock Loop possibly losing lock, error = <Phase error microns> microns (<Phase error clock cycles> clock cycles)
38191     MPC: The head unexpectedly reset
38192     MPC: The <Plate identifier> is positioned <Error distance> mm too close to the <Error direction> side
38193     MPC: The <Plate identifier> is positioned too close to the <Error direction> side
38194     MPC: The write laser is stuck calibrating
38195     MPC: The gc mainscan shift is too small
38197     MPC: The head is over the media at the minimum edge search position
38200     MIC: Error message with no error code
38201     MIC: Software error
38202     MIC: No image tasks available
38203     MIC: Image task is not active
38204     MIC: Image task is busy
38205     MIC: Image task is not suspended
38206     MIC: Image parameter is missing
38207     MIC: Image parameter is invalid
38208     MIC: Currently not initialized, waiting for FLUSH
38209     MIC: Flush is not complete
38210     MIC: Image parameters already received
38211     MIC: Too many image tasks requested
38212     MIC: Already unloading media
38213     MIC: Image cancelled by flush
38214     MIC: Cannot free unreserved image task
38215     MIC: Invalid image task identifier
38216     MIC: Cannot free busy image task
38217     MIC: Cannot free busy image task
38218     MIC: Fatal error
38219     MIC: Software error: <Additional information on the software error>
38220     MIC: Command aborted
38221     MIC: Task specified is not a valid image task
38222     MIC: Task specified cannot be cancelled
38223     MIC: Task has error, but a second error has occurred
38224     MIC: Image task specified is not a valid image (or not currently running)
38225     MIC: Task specified could not be found (no matching state machine)
38226     MIC: Task cancelled
38227     MIC: Task has not completed
38228     MIC: Flush not currently active
38229     MIC: Group index not in valid range
38230     MIC: Group image index not in valid range
38231     MIC: Group not valid, no images
38232     MIC: Invalid callback supplied
38233     MIC: Invalid image status structure supplied
38234     MIC: Invalid flush status structure supplied
38235     MIC: Invalid task parameter structure
38236     MIC: Invalid image parameter structure
38237     MIC: Invalid image list array supplied
38238     MIC: Invalid state type received in message
38239     MIC: Invalid command ID in command msg
38240     MIC: No state machines available
38241     MIC: State machine not found (no magic number match)
38242     MIC: State machines pointer invalid
38243     MIC: Message invalid, cannot parse
38244     MIC: Conditional false - internal only
38245     MIC: Invalid media type structure
38246     MIC: Media instance not being used by MIC
38301     MDS: Software error
38302     MDS: Software error, unable to allocate sequence data structure
38303     MDS: Software error, the Scheduler is trying to use a NULL sequence data struct
38304     MDS: Software error, the Scheduler is trying to use a invalid sequence structure pool
38305     MDS: Software error, the Scheduler is trying to use a invalid sequence structure linked list
38306     MDS: Software error, the Scheduler could not remove the sequence structure from the linked list
38307     MDS: Software error, unable to allocate media data structure
38308     MDS: Software error, the Scheduler is trying to use a NULL media data structure
38309     MDS: Software error, the Scheduler is trying to use a invalid media structure pool
38310     MDS: Software error, the Scheduler is trying to use a invalid media structure linked list
38311     MDS: Software error, the Scheduler could not remove the media structure from the linked list
38312     MDS: Software error, unable to allocate arguments data structure
38313     MDS: Software error, the Scheduler is trying to use a NULL arguments data structure
38314     MDS: Software error, the Scheduler is trying to use a invalid arguments structure pool
38315     MDS: Cancel command failed, Scheduler not currently processing any operation with specified media instance
38316     MDS: Scheduler could not schedule command since it did not have a proper arguments
38317     MDS: Image type specified is not supported by this machine
38318     MDS: Scheduler monitor command failed
38319     MDS: Initialization failed use 'resume' to re-attempt initialization
38320     MDS: Scheduler command aborted
38321     MDS: Scheduler command cancelled
38322     MDS: Software error, suspend button not defined
38323     MDS: No <media name> on the drum to unload
38324     MDS: Scheduler cannot cancel unload commands
38325     MDS: Cannot cancel initialization commands
38326     MDS: Cannot eject during an unload
38327     MDS: Cannot eject media during initialization
38328     MDS: Scheduler sequence is in an unknown state
38329     MDS: The <Media name> on the drum is already being unloaded
38330     MDS: Scheduler has no tasks currently suspended
38331     MDS: Software error, Scheduler received a bad Media Hander task ID in it callback
38332     MDS: Software error, Scheduler received an invalid action type when setting up its arrays
38333     MDS: Invalid parameter sent to monitor command
38334     MDS: Media already on drum, cannot force new media on drum
38335     MDS: The parameter 'media stacks' is not used, only 1 stack available
38336     MDS: The parameter 'bay' is not used, no bays are available on this device
38337     MDS: The parameter 'punch' is not used, no punches are available on this device
38338     MDS: The parameter 'exit' is not used, only one exit on this device
38339     MDS: Attempt to load proofing media without carrier or receiver on drum
38340     MDS: Media scheduler fatal error
38341     MDS: Media type argument is invalid, media type = <Media type value that is invalid>
38342     MDS: Media stacks argument is <Current media stack value>, maximum = <Maximum media stack value>
38343     MDS: Media stacks argument cannot be 0, must be 1 or greater
38344     MDS: Bay argument cannot be 0 for an automatic job
38345     MDS: Bay argument is <current bay argument>, maximum is <maximum number of bays>
38346     MDS: Bay argument is <current bay argument>, but it is a manual job so it should be 0
38347     MDS: Punch argument is <current punch argument>, maximum is <maximum number of punches>
38348     MDS: Exit argument is <current exit argument>, maximum is <maximum number of exits>
38349     MDS: Rotate argument is <current rotate argument>, rotator is not supported
38350     MDS: Image side argument is invalid, must be set to a defined value for this media
38351     MDS: Image side argument is not valid for this media, must be set to Side A
38352     MDS: Image side argument is greater than expected, set to a valid value
38353     MDS: Default load arguments have been reset to valid values
38354     MDS: Default unload arguments have been reset to valid values
38355     MDS: Invalid media instance, 0 is not a valid media instance
38356     MDS: Invalid media instance, does not match media on the drum
38357     MDS: Requested media is not loaded
38358     MDS: Stack locations specified for <number of stack locations specified> stack(s), however <number of stacks being loaded> stack(s) are being loaded
38359     MDS: Cannot unload <media type> since it is still being loaded (possibly suspended)
38360     MDS: Cannot unload <media type> since <media being loaded on top> is being loaded on top
38361     MDS: Cannot unload <media type> since <media name(s) on top> is/are loaded on top
38362     MDS: Media Scheduler operation is undefined
38363     MDS: Media Scheduler <Operation Sequence Type> operation (<Media Instance ID>) cannot be run because the Media Handler is not initialized
38364     MDS: Media Scheduler <Operation Sequence Type> operation (<Media Instance ID>) is not allowed to be cancelled
38365     MDS: Media Scheduler <Operation Sequence Type> operation (<Media Instance ID>) could not schedule cycle testing operations (error:<Error code>)
38366     MDS: Media Scheduler operation <Media Instance ID> has an unknown sequence type <Sequence Type>
38367     MDS: Media Scheduler <Operation Sequence Type> operation (<Media Instance ID>) could not find a sequence to run
38368     MDS: Media Scheduler could not find step Id <Step Id> in sequence
38369     MDS: Media Scheduler <Operation Sequence Type> operation (<Media Instance ID>) could not find synchronization step Id <Step Id> in sequence (process Id:<Process Id>)
38370     MDS: Media Scheduler could not find end step in sequence
38371     MDS: Media Scheduler step tracking is undefined
38372     MDS: Media Scheduler <Operation Sequence Type> operation <Media Instance ID> has reached its maximum step count <Maximum Step Count> for step Id <Step Id> (process Id<Process Id>)
38373     MDS: Media Scheduler <Operation Sequence Type> operation <Media Instance ID> has an undefined process
38374     MDS: Media Scheduler <Operation Sequence Type> operation <Media Instance ID> could not start a new process (maximum of <Max process count>)
38375     MDS: Media Scheduler <Operation Sequence Type> operation <Media Instance ID> could not find process <Process Id>
38376     MDS: Media Scheduler could not finish sequence scan, too many steps (maximum <Maximum number of scan steps>)
38377     MDS: Media Scheduler could not schedule bay close since the bay is not open
38378     MDS: Media Scheduler could not schedule bay close since one was already scheduled
38379     MDS: Media Scheduler decision type is not supported for step type
38380     MDS: Too many alternate bays, maximum is <Maximum number of alternative bays>
38381     MDS: The media type '<Media name>' is not currently allowed on this device
38400     NET: TRECK TCP/IP Stack is reporting a Fatal Error condition
38401     NET: Failure to activate SLIP link-layer protocol
38402     NET: Failure to activate PPP Server link-layer protocol
38403     NET: Failure to activate PPP Client link-layer protocol
38404     NET: Failure to activate EtherNet link-layer protocol
38405     NET: Failure to allocate internal memory - FATAL
38406     NET: Failure to add a device driver to TRECK TCP/IP Stack - FATAL
38407     NET: Failure to open a device driver for the TRECK TCP/IP Stack - FATAL
38408     NET: Interface device driver for the TRECK TCP/IP Stack is not open
38409     NET: Failure to query information about a h/w interface in the TRECK TCP/IP Stack - FATAL
38410     NET: Warning in TRECK function <Function name>: <Warning description>\n
38601     STP: Unable to write velocity, not in Host Velocity Control Mode
38602     STP: Attempt to read or write an invalid parameter
38603     STP: Attempt to write an invalid configuration flag
38604     STP: Attempt to write an invalid configuration mode
38605     STP: Attempt to write a stepper motor parameter that is out of range
38606     STP: Attempt to change the parameters of the system while the motor is moving
38607     STP: Trajectory queue address out of range
38608     STP: Motor does not exist on this board
38609     STP: Stepper hardware status check has failed
38610     STP: The Stepper Firmware has not been properly initialized
38611     STP: Stepper controller is awaiting an unsolicited message acknowledge
38800     WMD: Out of command/prompt/stream handles
38801     WMD: Invalid handle
38802     WMD: Internal error detected
38803     WMD: Solicitor number is currently used
38804     WMD: Command Table Full
38805     WMD: Prompt Descriptor Table Full
38806     WMD: Too many buttons for prompt
38807     WMD: An invalid button code was used
38808     WMD: An invalid prompt ID was used
38809     WMD: Illegal attempt to access prompt object
38810     WMD: Unsupported Workstation protocol
38811     WMD: Device is running\nUNSUPPORTED\nEngineering Firmware
38812     WMD: Invalid Command Code detected
38813     WMD: socket() call has failed
38814     WMD: bind() call has failed
38815     WMD: listen() call has failed
38816     WMD: accept() call has failed
38817     WMD: recv() call has failed
38818     WMD: send() call has failed
38819     WMD: WSAStartup() call has failed
38820     WMD: ioctlsocket() call has failed
38821     WMD: Command is rejected because of service lockout
38822     WMD: Service lockout
38823     WMD: No socket connection with workstation.
38824     WMD: Invalid data unit size RCON parameter in Read Memory or Write Memory command
38825     WMD: Too many workstation status change callbacks have been registered
38826     WMD: The RCON connection to the workstation has been lost
38827     WMD: Workstation is not detected
38828     WMD: Too many workstation command received callbacks have been registered
39000     SAT: The board type is unknown
39101     SIF: SIF/SCON General Failure
39102     SIF: Received an SCON NAK reply
39103     SIF: SCON Operation timed out
39104     SIF: No Free CAN Transmit Buffers available
39105     SIF: The SIF Subsystem has detected a reentrancy attempt
39106     SIF: The SIF Subsystem has not been initialized properly
39107     SIF: The SIF Subsystem has run out of queue buffers
39108     SIF: SIF Serial port Open has failed due to not being activated for SIF serial support
39301     SIO: SIO General Failure
39302     SIO: Failure to Register with SIF
39303     SIO: SAT I/O Node does not exist
39304     SIO: The Unsolicited Callback Information Block has Become Corrupted
39305     SIO: The Call Back Function Specified is Invalid
39306     SIO: Attempt to register too many callbacks with the SIO subsystem
39307     SIO: All SCON Connection resources are in use - no more left
39400     GIM: Invalid Image ID
39402     GIM: Internal firmware error
39403     GIM: Invalid Image Parameter
39404     GIM: Please load a new plate
39405     GIM: Please unload the ejected media
39406     GIM: Required data was locked by another subsystem
39407     GIM: Not ready for Flush End command
39408     GIM: No flush active that can be ended.
39409     GIM: Invalid Flush state detected
39410     GIM: Device is unlocked
39411     GIM: Head not initialized: not ready for query
39412     GIM: Unrecoverable Flush Failure. Device must be reset.
39413     GIM: Invalid Image Task ID detected
39414     GIM: Invalid bay number detected
39415     GIM: WARNING: Bypassed functionality detected
39417     GIM: Carriage command received while carriage is busy
39418     GIM: Invalid carriage velocity value attempted
39419     GIM: Invalid carriage position value attempted
39420     GIM: Invalid latch number
39421     GIM: Invalid sensor number
39422     GIM: Invalid latch value code
39424     GIM: Unexpected Command
39427     GIM: Flush is required before operation permitted.
39430     GIM: Invalid Group ID
39432     GIM: Too many images in Group
39433     GIM: No group available
39434     GIM: The device cannot support the number of stacks queried
39435     GIM: Suspend queue is full, cannot handle any more suspends
39436     GIM: Suspend could not be found, not removed
39437     GIM: Please load carrier
39438     GIM: Please unload the ejected carrier
39439     GIM: Invalid group parameter
39440     GIM: Please load receiver
39441     GIM: Please load donor
39442     GIM: RCON command is missing argument '<Name of the missing parameter name>'
39443     GIM: Invalid RCON variable argument specified '<Name of the invalid argument name>'
39444     GIM: Unknown or invalid property ID specified
39445     GIM: Invalid operation attempted on property '<Name of the DCAPI property could not be manipulated>'
39448     GIM: RCON media instance is unknown or invalid
39449     GIM: The system is attempting to simultaneously access too many media instances
39450     GIM: No media is available. Requested media operation cannot be performed.
39451     GIM: Property Not supported
39452     GIM: Invalid arguments specified in Set Seam Geometry request
39453     GIM: Prompt array full, cannot make new prompt
39454     GIM: Could not find prompt
39455     GIM: Workstation command locked out
39457     GIM: Invalid or unsupported combination of arguments
39458     GIM: Service move command received while device is processing a previous move command
39459     GIM: The imaged area is not yet available for reading
39461     GIM: Please load a new plate on the home side
39462     GIM: Please load a new plate on the away side
39463     GIM: Please load a new plate in the center
39464     GIM: Please load two new plates
39465     GIM: Status Handler table full
39466     GIM: Workstation watchdog timed out. Shutting down all systems.
39469     GIM: Bay media configurations must match for transfer
39471     GIM: Invalid arguments specified in Set Punch Regions request
39472     GIM: Not enough free Media Handler descriptors to start a new Media Handler operation
39473     GIM: Media Handler operation specified could not be found
39501     IOS: software error
39502     IOS: Insufficient memory to create IO scanner tables
39503     IOS: I/O Bit not found in product table
39504     IOS: I/O Group not found in product table
39505     IOS: Event group pointer is null
39506     IOS: Can't assign non-input bit to event group
39507     IOS: IO values are not initialized
39508     IOS: Bypass not allowed on this I/O
39509     IOS: No remote address for requested bit
39510     IOS: No remote address for requested bit
39511     IOS: Invalid IOS mode
39512     IOS: IO Name Identifier too long
39513     IOS: Incorrect number of IO Data bytes
39514     IOS: Workstation command locked out
39515     IOS: Conversion function not available
39516     IOS: Callback table full
39517     IOS: Bit handle already has an event registered
39518     IOS: Satellite board address <The satellite board ID that is not responding> register <The register address being accessed> not responding
39519     IOS: TCP/IP failure
39800     SST: Invalid API Function Parameter Detected
39801     SST: Internal SST error
39802     SST: Invalid SST handle
39803     SST: Status group not registered
39804     SST: Invalid SST I/O type
39805     SST: Specified I/O not found
39806     SST: Invalid upper and lower thresholds for analog I/O
39807     SST: Invalid digital target value
39808     SST: Invalid I/O failure priority level
39809     SST: System is not in initialization mode
39900     MBT: Fatal Error - Fell out of Monitor code
39901     MBT: Fatal Error - Boot Code is Corrupt
39902     MBT: Fatal Error - Insufficient Heap Memory available
40001     SMC: Software error
40002     SMC: CAN communication error
40003     SMC: Cannot issue command, motor is moving [<Name of the stepper motor>]
40004     SMC: Cannot issue command, motor is being controlled by another process and is reserved [<Name of the stepper motor>]
40005     SMC: Motor number out of range or the motor is not configured on this device
40006     SMC: Invalid trajectory queue address specified [<Name of the stepper motor>]
40007     SMC: Invalid parameter specified [<Name of the stepper motor>]
40008     SMC: Invalid velocity value specified [<Name of the stepper motor>]
40009     SMC: Invalid acceleration value specified [<Name of the stepper motor>]
40010     SMC: Invalid micro step rate specified [<Name of the stepper motor>]
40011     SMC: Invalid current specified [<Name of the stepper motor>]
40012     SMC: Invalid direction mode parameter specified [<Name of the stepper motor>]
40013     SMC: Remote hardware is not processing motor commands [<Name of the stepper motor>]
40014     SMC: Stepper motor name not found
40015     SMC: Motor unexpectedly hit the home sensor [<Name of the stepper motor>]
40016     SMC: Motor unexpectedly hit the away sensor [<Name of the stepper motor>]
40017     SMC: Stepper command timed out [<Name of the stepper motor>]
40018     SMC: The remote board hardware status check has failed [<Name of the stepper motor>]
40019     SMC: Invalid motor gain parameter specified [<Name of the stepper motor>]
40020     SMC: Motor initialization has failed [<Name of the stepper motor>]
40021     SMC: Remote motor has not been initialized [<Name of the stepper motor>]
40022     SMC: Invalid update mode parameter specified [<Name of the stepper motor>]
40023     SMC: Invalid position specified [<Name of the stepper motor>]
40024     SMC: Invalid steps per real unit specified [<Name of the stepper motor>]
40025     SMC: Invalid distance specified [<Name of the stepper motor>]
40026     SMC: Invalid initialization parameters specified [<Name of the stepper motor>]
40027     SMC: Command failed, the shared motor is using all the remote bandwidth [<Name of the stepper motor>]
40028     SMC: Invalid initialization dual stepper mode specified [<Name of the stepper motor>]
40029     SMC: Move command preempted
40030     SMC: Failed to detect 48V [<Name of the stepper motor>]
40031     SMC: Failed to detect alternate sensor cable [<Name of the stepper motor>]
40032     SMC: Failed to detect home and away cable [<Name of the stepper motor>]
40033     SMC: Failed to detect power cable [<Name of the stepper motor>]
40034     SMC: Failed to detect data cable [<Name of the stepper motor>]
40035     SMC: Over current fault detected [<Name of the stepper motor>]
40036     SMC: Over temperature fault detected [<Name of the stepper motor>]
40037     SMC: Under voltage fault detected [<Name of the stepper motor>]
40038     SMC: Driver fault detected [<Name of the stepper motor>]
40039     SMC: Failed to detect the cable [<Name of the stepper motor>]
40040     SMC: Brake override detected [<Name of the stepper motor>]
40041     SMC: Invalid maximum jerk value specified [<Name of the stepper motor>]
40042     SMC: Input value is outside the limits [<Name of the stepper motor>]
40043     SMC: Satellite board has reset, stepper control has failed [<Name of the stepper motor>]
40044     SMC: Velocity of <Velocity specified in real units/s> units/s [<Velocity specified in steps/s> steps/s] is too high, max is <Maximum velocity allowed in real units/s> units/s [<Maximum velocity allowed in steps/s> steps/s] [<Name of the stepper motor>]
40045     SMC: Velocity of <Velocity specified in real units/s> units/s [<Velocity specified in steps/s> steps/s]is too low, min is <Minimum velocity allowed in real units/s> units/s [<Minimum velocity allowed in steps/s> steps/s] [<Name of the stepper motor>]
40046     SMC: Motor already has a reset callback [<Name of the stepper motor>]
40047     SMC: Satellite board does not support quarter current mode [<Name of the stepper motor>]
40048     SMC: The motor has been stopped before the motor has started [<Name of the stepper motor>]
40049     SMC: Remote motor is waiting for an acknowledge [<Name of the stepper motor>]
40050     SMC: Remote motor has failed with an undefined error <The undefined error> [<Name of the stepper motor>]
40100     SBT: Fatal Error - Fell out of Monitor code
40101     SBT: Fatal Error - Boot Code is Corrupt
40102     SBT: Fatal Error - Insufficient Heap Memory available
40103     SBT: Fatal Error - Failure Registering VR Handler with SIF
40104     SBT: Fatal Error - Failure Registering Broadcast Handler with SIF
40105     SBT: Warning - Failure to Erase a Flash Sector
40200     MDH: <motor name> stepper motor has already started the command, cannot start it again
40201     MDH: Software error. Media Handler error occurred, but error has no error code.
40202     MDH: Software error. Suspend received a invalid suspend button type.
40203     MDH: Software error. Media Handler received an unrecognized command.
40206     MDH: Command Failed. Media Handler already running another task.
40207     MDH: Cannot cancel command. Media Handler task is not currently executing any commands.
40208     MDH: Media handler task is currently suspended.
40209     MDH: Media handler is not currently suspended.
40212     MDH: Media Handler task cancelled
40213     MDH: Media released from the drum and removed from the machine.
40214     MDH: Forced failure.
40216     MDH: Cannot enable/disable cycletest mode when machine not idle.
40217     MDH: Cannot enable/disable 'plateless' operation when machine not idle.
40228     MDH: Media Handler task aborted
40230     MDH: Invalid actuator timeout (must be non-zero)
40231     MDH: <motor name> stepper motor cannot search for a sensor [<I/O name>] if waiting is not specified
40237     MDH: <motor name> stepper motor recieved an invalid setup parameter
40238     MDH: <motor name> stepper motor has not started a command, cannot wait for it to complete
40239     MDH: Software Error. The error code contains the wrong number of parameters
40240     MDH: Fatal error
40242     MDH: Could not set the media on the drum
40243     MDH: <motor name> stepper motor did not reach the sensor it was searching for [<I/O name>]
40244     MDH: Stepper motor cannot search for a sensor that has been disabled [<I/O name>]
40245     MDH: Command cannot be cancelled
40246     MDH: Media released, remove media and use MEDIA REMOVED to continue
40251     MDH: Media Handler does not support simulation option <Option>
40254     MDH: Media handler sequence attempted to use auto-retry on step that pointed to a different step
40257     MDH: Software error. Wrong or invalid argument supplied
40258     MDH: Could not find step '<Step description>' in sequence
40259     MDH: <Motor name> stepper motor did not reach the sensor it was searching for [<I/O name>]
40267     MDH: <Motor name> stepper motor unexpectedly hit the home sensor
40275     MDH: <Motor name> stepper motor unexpectedly hit the away sensor
40283     MDH: <Motor name> stepper motor failed to respond
40292     MDH: The Media Handler experienced an internal error, restart the device
40293     MDH: <motor name> stepper motor has not completed previous command
40294     MDH: <motor name> stepper motor sensor mask(s) are setup but motor is not setup to wait for completion
40295     MDH: Operation failed, but no error setup (device actuate)
40296     MDH: <motor name> stepper motor waited for <timeout in seconds> seconds, but setup command did not complete
40297     MDH: <sequence type> (<sequence id>) sequence is not available with these arguments
40298     MDH: <sequence type> (<sequence id>) sequence is not supported on this device
40301     MDH: Invalid bay number (bay #<Bay number>) selected
40302     MDH: No plates detected in bay <Bay number>
40303     MDH: No plates detected on plate buffer table
40341     MDH: Bay <loader bay number> is not accessible because the preloader is docked
40342     MDH: Cannot move the bay hardware, it has not been initialized
40343     MDH: The plate cover must be open for the preloader
40344     MDH: Undock the preloader and remove the plate(s) from the bay, then dock the preloader again
40345     MDH: Please remove plate(s) from the outer bay [<I/O name>]
40346     MDH: The plate stack is too high to deploy the outer bay arms
40401     MDH: Picker up/down timeout: Failed to <Action> sensor. [<I/O name>]
40402     MDH: Picker in/out timeout: Failed to <Action> sensor. [<I/O name>]
40403     MDH: Picker wrist timeout: Failed to <Action> sensor. [<I/O name>]
40404     MDH: Picker vacuum timeout: Failed to achieve vacuum threshold (<Threshold>) within <Timeout> ms (only reached <ActualValue>). [<I/O name>]
40405     MDH: Cannot move the picker, it has not been initialized
40406     MDH: Plate not detected on picker
40407     MDH: Please remove plate detected on picker
40408     MDH: Please close plate cover
40409     MDH: Cannot move picker <Direction> because <Obstruction>
40410     MDH: Plates are sticking together. Please open the plate cover and separate the plates. Press RESUME to continue.
40411     MDH: Timeout waiting for plate cover to be opened/closed. Command cancelled
40412     MDH: Device ready. Close plate cover to continue.
40413     MDH: Picker wrist sensor is not working
40414     MDH: Picker wrist cylinder is faulty
40415     MDH: Separator arm timeout: Failed to <Action> sensor. [<I/O name>]
40416     MDH: Cannot move separators <Direction> because <Obstruction>
40417     MDH: Please close plate cover, or put the preloader into position
40420     MDH: The Preloader is in a faulted state. Please check the Preloader display for more information
40421     MDH: The Preloader is not ready. It may be out of position, open, or not fully powered on
40423     MDH: The Preloader is not powered on. Please check the Preloader connections
40424     MDH: The Preloader is in the bay. Please check the Preloader display for more information
40425     MDH: The Preloader is not loading plates properly into the Trendsetter bay. Please check the Preloader display for more information
40426     MDH: No plates detected in the bay. The plate may not have been properly loaded by the Preloader
40428     MDH: Loader exit door timeout: Failed to <Action> sensor. [<I/O name>]
40429     MDH: Picker cups in/out timeout: Failed to <Action> sensor. [<I/O name>]
40430     MDH: Cannot open exit door because an unpicked plate is detected. Please remove all plates from the plate buffer load table.
40450     MDH: Picker up/down timeout: Failed to <Action> sensor. [<I/O name>]
40466     MDH: Picker was expected to be down and out but was not
40467     MDH: Exit door was expected to be closed but was not
40607     MDH: Clamps expected to be on the trailing edge backbone, but they were not detected
40608     MDH: Clamps detected on the trailing edge backbone, but they were not expected
40616     MDH: Roller timeout: Failed to <Action> sensor. [<I/O name>]
40622     MDH: LEC down preventing roller move down
40624     MDH: Media being loaded has been measured to have an unexpected main scan length
40625     MDH: Media being loaded has an invalid mainscan length, min=<Minimum mainscan length in mm> mm, max=<Maximum mainscan length in mm> mm
40626     MDH: Media being loaded has an invalid subscan length, min=<Minimum mainscan length in mm> mm, max=<Maximum mainscan length in mm> mm
40629     MDH: Media partially loaded on drum, use RELEASE then remove the media
40630     MDH: Media fully on drum
40632     MDH: Media flyoff detected, please open panel and remove media
40634     MDH: Media is expected on the drum, but no media was found
40635     MDH: Cannot execute command because the drum is moving
40636     MDH: Drum not at the expected position, position may have shifted because of outside interaction
40638     MDH: Drum not initialized, use 'drum init' to initialize
40652     MDH: Cannot calibrate (media size measurement sensor bypassed)
40663     MDH: Leading edge clamp timeout: Failed to <Action> sensor. [<I/O name>]
40664     MDH: Trailing edge backbone timeout: Failed to <Action> sensor. [<I/O name>]
40665     MDH: Trailing edge clamp lock/unlock timeout: Failed to <Action> sensor. [<I/O name>]
40666     MDH: Exit door timeout: Failed to <Action> sensor. [<I/O name>]
40667     MDH: Load ramp timeout: Failed to <Action> sensor. [<I/O name>]
40668     MDH: Please remove media detected on load ramp
40669     MDH: Media not detected on load ramp
40670     MDH: Please move clamps to park position, then select RESUME
40684     MDH: Roller is down, cannot move LEC
40692     MDH: Engine is currently busy, cannot change drum state
40712     MDH: Cannot execute command because LEC is not down
40713     MDH: Cannot execute command because TEC is not down and locked to clamps
40722     MDH: Stack locations (<Bit-field of the locations>) are not valid media positions
40725     MDH: Invalid stack count and rotate flag combination
40728     MDH: Media is too <Limit type> to rotate, limit is <Limit amount> mm
40740     MDH: TEC adjust <Current TEC adjust> is too small for this plate size, should be at least <Recommended TEC adjust>
40741     MDH: Trailing edge clamp position invalid - load calibration required
40742     MDH: Media has invalid main scan length <MeasuredLength> mm, it is smaller than expected <ExpectedLength> mm
40743     MDH: Media has invalid main scan length <MeasuredLength> mm, it is larger than expected <ExpectedLength> mm
40744     MDH: Media has invalid main scan length, it is larger than expected <ExpectedLength> mm
40745     MDH: Media with a subscan size of <SubscanSize> cannot be loaded at location '<Location>'
40801     MDH: Unload table up/down timeout: Failed to <Action> sensor. [<I/O name>]
40802     MDH: Unload table cups up/down timeout: Failed to <Action> sensor. [<I/O name>]
40803     MDH: Unload table vacuum timeout: Failed to achieve vacuum threshold (<Threshold>) within <Timeout> ms (only reached <ActualValue>). [<I/O name>]
40804     MDH: Cannot move the unload table, it has not been initialized
40805     MDH: Timeout waiting for plate to leave unload table
40806     MDH: Unload cups rotated, cannot move unload table cups
40807     MDH: Unload stepper motor not in safe position to rotate cups
40809     MDH: Please remove plate detected on unload table [<I/O name>]
40810     MDH: Rotator timeout: Failed to <Action> sensor. [<I/O name>]
40811     MDH: Unable to pull media out of engine. Media still detected at entry sensor [<I/O name>]
40812     MDH: Media not detected at unload table entry [<I/O name>]
40813     MDH: Invalid exit number (exit #<Exit number>) selected
40814     MDH: The processor is not ready to accept plates
40815     MDH: The processor is in a faulted state
40816     MDH: The processor is still busy with the previous plate, so is unable to accept another
40822     MDH: The rotate option is not available on this device
40825     MDH: Workstation cannot connect to the PMI.\nPress RESUME when the processor is ready to accept the next plate
40936     MDH: Drum vacuum timeout: Failed to fall below vacuum threshold (<Threshold> kPa) within <Timeout> sec (only reached <ActualValue> kPa). [<I/O name>]
41500     OWB: Internal Error - 1-Wire-Bus response buffer became full
41501     OWB: OWB General Failure
41502     OWB: The 1-Wire-Bus appears to be shorted.
41503     OWB: An Alarm presence pulse was found on the 1-Wire-Bus.
41504     OWB: No node presence pulse was found on the 1-Wire-Bus.
41505     OWB: The 1-Wire-Bus adapter (DS1411) is not responding.
41506     OWB: Bad CRC received from a Node ID on the 1-Wire-Bus.
41507     OWB: Write Data failed to verify from a Node on the 1-Wire-Bus.
41514     OWB: No more Nodes on the 1-Wire-Bus.
41800     IBM: General Failure
41801     IBM: Invalid iButton Scanner data point handle
41802     IBM: Cannot write to an iButton handle that is a READ value
41803     IBM: Could not find the requested iButton handle
41804     IBM: iButton Manager (IBM) is not initialized
41805     IBM: The requested iButton handle is not available
42900     PST: POST: <Test Code> - <Test Description>
42901     PST: No response received from <Satellite Board>
42902     PST: Unknown satellite board (ID=<Satellite ID>) found
42903     PST: Invalid mode parameter in RCON command Get Post Result
42999     PST: Machine Electronics FAILED Power On Self-Tests
43001     DEB: Debris removal software error: <Software error>
43002     DEB: Particulate Only Collection (POC) debris removal is not enabled on this device
43003     DEB: Particulate and Chemical Collection (PACC) debris removal is not enabled on this device
43004     DEB: The air jet is enabled, but not turned on
43005     DEB: The blower is not turned on
43006     DEB: The flow rate is below the minimum required
43007     DEB: The cabinet has lost power
43008     DEB: The particulate filter is not present or upside down, the lid is not closed, or the data cable is disconnected
43009     DEB: The particulate filter is almost full. Please ensure a replacement filter is on hand
43010     DEB: The particulate filter is full. You must replace the particulate filter to continue imaging
43011     DEB: The debris collection nozzle is blocked
43012     DEB: The debris hose is disconnected
43013     DEB: There is a problem with one or more of the pressure sensors in the debris removal cabinet
43014     DEB: The debris hose is disconnected, the cabinet has lost power, or the cabinet lid is not latched properly
43015     DEB: There may be a partial blockage of the collection nozzle, or a leak, but the flow rate is still above minimum
43016     DEB: There is a partial blockage of the collection nozzle, or a leak, and the flow rate is below minimum
43017     DEB: The media being imaged releases potentially harmful emissions. See the Operator Manual for more information
43018     DEB: The debris removal chemical filter is not present
43019     DEB: The chemical filter has almost expired. Please ensure a replacement filter is on hand
43020     DEB: The chemical filter has expired. You must replace the chemical filter and reset the output device to continue imaging
43021     DEB: The chemical filter usage sensor is corrupt or the chemical filter was changed and the output device was not reset
43022     DEB: Unable to communicate with the chemical filter. See the Operator Manual for more information
43023     DEB: The chemical filter usage calculated is negative
43024     DEB: Unable to calibrate <Sensor Name> pressure sensor
43025     DEB: Unable to communicate with the chemical filter during initialization. See the Operator Manual for more information
43026     DEB: Timeout: the pressure sensor output failed to stabilize
43027     DEB: No debris removal options are enabled on this device
43028     DEB: There is a problem with the nozzle pressure sensor in the output device
43029     DEB: Command failed: cannot run more than one PACC option at a time
43030     DEB: Cannot start new debris option while another is in an error condition
43031     DEB: The chemical filter installed is not suitable for the selected media
43032     DEB: The particulate filter is almost full AND the chemical filter has almost expired
43033     DEB: Cannot setup ibutton: <IButton Parameter>
43034     DEB: Chemical filter iButton already has valid usage information, did not reprogram
43035     DEB: Conversion failed.
43301     CRG: software error
43302     CRG: Carriage initialization timed out <Initialization operation>
43303     CRG: Carriage is reserved, command ignored
43304     CRG: The current carriage command has been preempted
43305     CRG: Carriage Hardware Fault: <Description of the faulted hardware component>
43306     CRG: Requested carriage velocity too high, recommended max = <Recommended maximum carriage velocity> mm/sec
43307     CRG: Carriage Accel requires Ispeed, Mspeed or velocity in range +/- <Maximum carriage velocity using current acceleration value> mm/s
43308     CRG: Carriage travel limit (<Text string describing which limits signals are active as follows>) unexpectedly hit
43309     CRG: Carriage velocity exceeds register size
43310     CRG: Carriage has aborted plotting
43311     CRG: Carriage can not reach requested position
43312     CRG: Carriage Amplifier fault: <Text string describing specific amplifier fault>
43313     CRG: Carriage currently initializing
43314     CRG: Carriage not initialized
43500     DF1: internal memory allocation error - DF1 Driver
43501     DF1: failure to open to the URT Subsystem - DF1 Driver
43601     MOP: MOP Initialization failed
43602     MOP: Argument name not found or used token in place of argument
43603     MOP: MOP API() function can only be used with optional tokens
43604     MOP: Internal MOP firmware error
43605     MOP: Unregistered MOP commands or MOP commands registered twice
43606     MOP: An invalid MOP access level was selected
43701     ZAD: Could not read the Z-Drive parameters
43702     ZAD: Command not expected at this time
43703     ZAD: Internal firmware error
43704     ZAD: Command was aborted
43705     ZAD: Error sending SMC motor command
43706     ZAD: Zdrive stopped by external command
43707     ZAD: Zdrive not initialized, position is unknown
43708     ZAD: Zdrive motor could not be initialized, zdrive cannot be used
43709     ZAD: Zdrive is busy
43710     ZAD: Zdrive is busy trying to abort
43711     ZAD: Zdrive is busy trying to stop
43712     ZAD: Zdrive is in invalid state
43713     ZAD: Zdrive received an invalid message
43714     ZAD: Zdrive invalid internal structure
43715     ZAD: Zdrive received an invalid state message
43716     ZAD: Zdrive received an invalid message type
43717     ZAD: Zdrive received an invalid message code
43718     ZAD: Zdrive requires SMC version <SMC Version major>.<SMC Version minor>
43802     ZAC: Another z axis sequence is currently being processed
43803     ZAC: Internal: Invalid parameter passed to function
43804     ZAC: Internal: System resource unavailable
43805     ZAC: Focus Error value requested while focus out of range or saturated
43806     ZAC: Z Axis Focus routine aborted by monitor command
43807     ZAC: Media not found by Z axis, confirm dimensions
43808     ZAC: Media not found by Z axis, confirm dimensions
43809     ZAC: Head operation timed out
43810     ZAC: Media not found by Z axis due to head collision, confirm dimensions
43811     ZAC: Eccentric media surface: Probable cause out-of-round cylinder / bad mount
43900     CTP: CTP Engine Component is not present - internal firmware error
43901     CTP: CTP Processor Connected to Device
43902     CTP: CTP Processor Not Enabled
43903     CTP: Load or unload method not supported
43904     CTP: Lost communication with the slave board
43905     CTP: Master/slave operation timed out
44201     DTL: Non-head type message sent to DTL Driver
44202     DTL: DTL Driver unable to determine message type
44203     DTL: DTL Driver: invalid logical channel number
44204     DTL: DTL head communication sync lost
44205     DTL: DTL communication port not open
44206     DTL: Timeout attempting to close communication port
44207     DTL: DTL Server received a packet bigger than allowed
44208     DTL: DTL Server received a packet containing an illegal command
44209     DTL: DTL server or client failed to establish a TCP/IP connection
44210     DTL: TCP socket is shut down locally or remotely
44211     DTL: Internal error of TCP protocol
44212     DTL: TCP socket create failure
44213     DTL: TCP socket connect failure
44214     DTL: TCP protocol received an invalid packet
44215     DTL: TCP protocol link is not ready
44300     CEH: Error Code [<Error code>] <Error string>
44301     CEH: Warning Fault [<Error code>] <Error string>
44302     CEH: Fatal Fault [<Error code>] <Error string>
44303     CEH: The write laser request is in progress
44304     CEH: The stroke calibration is in progress
44305     CEH: The focus request is in progress
44306     CEH: The requested media is not supported by the exposure head
44307     CEH: An upgrade of the host firmware is recommended
44308     CEH: An upgrade of the exposure head firmware is recommended
44309     CEH: An upgrade of the host firmware is required
44310     CEH: An upgrade of the exposure head firmware is required
44311     CEH: The requested functionality is not supported by the exposure head
44401     BOS: BOS subsystem not initialized - cannot proceed.
44402     BOS: The requested update rate for the BOS subsystem is less than 50 ms
44403     BOS: Error creating BOS group: Output bit already used elsewhere
44404     BOS: Error creating BOS group: Too many outputs in group, max is 15
44405     BOS: BOS Handle specified is invalid, cannot process action
44406     BOS: New state for BOS group is invalid, cannot update group state.
44407     BOS: BOS has run out of empty groups and so cannot create a new one.
44408     BOS: BOS timed out trying to find a handle for a new group.
44500     EHI: The exposure head is offline
44501     EHI: The exposure head is being initialized
44502     EHI: The exposure head has failed
44503     EHI: The exposure head is in programming mode
44504     EHI: The exposure head has been disabled
44505     EHI: Head command transporter is not open
44506     EHI: Head command transporter failure
44507     EHI: The response / unsolicited packet is invalid
44508     EHI: The response / unsolicited packet length is invalid
44509     EHI: The response / unsolicited packet protocol is invalid
44510     EHI: The unsolicited packet is not supported
44511     EHI: The exposure head control mode is invalid
44512     EHI: The exposure head type is invalid
44513     EHI: The exposure head control mode transition is invalid
44514     EHI: The exposure head has unexpectedly reset
44515     EHI: The baud rate negotiation algorithm has failed
44516     EHI: The application protocol negotiation algorithm has failed
44517     EHI: The command packet is not supported
44518     EHI: The exposure head is not supported
44519     EHI: Baud rate negotiation is not supported by the exposure head
44520     EHI: Application protocol negotiation is not supported by the exposure head
44521     EHI: The error string cannot be determined; the exposure head type is unknown
44522     EHI: The error string could not be retrieved from the exposure head
44523     EHI: The functionality is not supported
44524     EHI: Monitor redirection is not supported
44525     EHI: A parameter is invalid
44526     EHI: EHI port closed before head commands complete
44527     EHI: Command response from exposure head took too long
44528     EHI: Response from head incorrectly sequenced
44529     EHI: Parameter load already in progress
44530     EHI: Specified parameter group unknown
44531     EHI: Changed parameter unknown in thermal head
44532     EHI: The monitor command requires the exposure head to be online
44533     EHI: The monitor command requires application protocol 0
44534     EHI: The monitor command requires a Thermal 1.0 or Thermal 1.7x exposure head
44535     EHI: The monitor command requires a Tfx or Thermal 2 exposure head
44536     EHI: The Thermal 1.0 or Thermal 1.7x exposure head was unable to learn focus
44537     EHI: Timeout waiting for the focus
44538     EHI: Timeout waiting for the write laser
44539     EHI: The firmware version of the exposure head is not supported
44540     EHI: Unexpected software failure
44541     EHI: Head Command Transaction Buffer Overflow
44542     EHI: Head Media Data Block format is unsupported
44543     EHI: Timeout during head redirection access attempt
44544     EHI: Parameter access buffer overrun attempted
44545     EHI: The redirected command to the head failed
44546     EHI: The Media Data Block is missing data
44547     EHI: The head has requested to be powered down
44600     MPI: Carrier not loaded or specified Proof Index is out of range
44601     MPI: Invalid proof type
44602     MPI: Invalid proof border types
44603     MPI: No more media supported
44604     MPI: Media Image Mode ID out of range: <MIMID>
44605     MPI: Media matching MIMID not found
44606     MPI: Corrupted internal value detected
44607     MPI: Internal firmware failure
44608     MPI: MPI subsystem not initialized.
44609     MPI: Exposure head not available.
44610     MPI: Media name is blank or invalid
44611     MPI: Head operation timed out
44612     MPI: Invalid or unrecognized Media Data Block
44613     MPI: Media index out of range: <Media index>
44614     MPI: Buffer overflow
44615     MPI: MIMID <MIMID> already in use by slot <Slot Number>
44800     EHI: no error
44801     EHI: temperature out of range
44802     EHI: value out of range
44803     EHI: missing laser on parameters
44804     EHI: attempted write blocked
44805     EHI: failure to write to memory
44806     EHI: unsupported message
44807     EHI: message length incorrect
44808     EHI: invalid control message
44809     EHI: operation was aborted
44832     EHI: no more room in mailbox
44833     EHI: ran out of buffers
44834     EHI: all retries failed on chnl 0
44835     EHI: all retries failed on chnl 1
44836     EHI: sync lost on chnl 0
44837     EHI: sync lost on chnl 1
44848     EHI: CONFIG register incorrect
44849     EHI: flash memory checksum error
44850     EHI: LCA won't init for reprogram
44851     EHI: LCA won't admit being loaded
44852     EHI: SRAM memory check failure
44896     EHI: software error
44897     EHI: LCA config unavailable
44898     EHI: LCA not found
44899     EHI: hardware timeout
44946     EHI: WLC PCB overheated, reset head
44947     EHI: Laser drive current limit
44948     EHI: Laser safety interlock is open
44949     EHI: DTD laser diode over temperature
44950     EHI: DTD laser diode over voltage
44951     EHI: DTD laser diode over current
44952     EHI: DTD +24V supply low
44953     EHI: DTD +24V supply high
44954     EHI: DTD +15V supply low
44955     EHI: DTD temperature sensor open circuit
44956     EHI: DTD software timeout
44957     EHI: DTD reset asserted
44958     EHI: DTD temperature below set point
44959     EHI: DTD temperature above set point
44960     EHI: shutter disabled
44961     EHI: reset detected
44962     EHI: laser disabled
44963     EHI: focus not initialized: Execute 'focus init'
44964     EHI: focus error detected at <Subscan location> mm <Relative location> while imaging, check plate for artifacts
44965     EHI: laser shutdown detected
44966     EHI: head case over temperature, <Case temperature> C
44967     EHI: head ambient over temperature, <Ambient temperature> C
44968     EHI: media <Media number> not found in HDM nvs subsystem
44969     EHI: crash detected, error code = 0x<Error code>
44970     EHI: Warning - head temperature high, <Case temperature> C
44971     EHI: SCORR out of range
44972     EHI: checksum error in <NVS subsystem> calibration block
44973     EHI: checksum error in <NVS subsystem> configuration block
44974     EHI: newline error, check drum encoder and LC-BP cable
44975     EHI: media thickness out of range
44976     EHI: EH-PHI cbl. (hotlink fault)
44977     EHI: LV 24V not in range (unipolar)
44978     EHI: LV 24V or High voltage fault
44979     EHI: LV Over temperature
44980     EHI: LV Too much stray light for beam balance
44981     EHI: LV Negative 12V fault (unipolar)
44982     EHI: LV Bias current fault (unipolar)
44983     EHI: Recalibration is on
44984     EHI: Recalibration fault
44985     EHI: checksum error in stroke correction download
44986     EHI: LV Not enough light for beam balance
44987     EHI: stroke clock frequency invalid, aborting download
44988     EHI: DTD status unstable
44989     EHI: Laser sampling disabled (wsample == 0)
44990     EHI: Beam position sampling disabled (bsample == 0)
44991     EHI: Focus sampling disabled (fsample == 0)
44992     EHI: Light level too low for Beam Pointing
44993     EHI: Timeout waiting for LASER OK
44994     EHI: Light valve high voltage fault
44995     EHI: LV Positive 12V fault (bipolar)
44996     EHI: Stroke Clock or Imaging signal fault, check LC-BP cable
44997     EHI: Focus sensor fails linearity test, check head position
44998     EHI: Laser safety loop has just been closed
44999     EHI: Laser safety loop has just opened
45000     EHI: Only the safety loop detected by the head has closed
45001     EHI: Only the safety loop detected by the laser has closed
45008     EHI: executive call tsk_create() failed
45009     EHI: all tasks suspended
45010     EHI: executive call mbx_create() failed
45011     EHI: executive call mbx_send() failed
45012     EHI: executive call buf_alloc() failed
45013     EHI: executive call tmr_create() failed
45014     EHI: Task received message that was not sent
45015     EHI: Task sending message owned by another task
45016     EHI: Task sending unreserved message
45017     EHI: message buffer request failed
45018     EHI: Reserved message in message pool
45019     EHI: Task releasing message owned by another task
45020     EHI: Task releasing unreserved message
45021     EHI: message buffer release failed
45022     EHI: Unexpected message in mailbox
45023     EHI: Command parameter error
45024     EHI: Laser beam positioning not stable yet
45025     EHI: LV serial communications TX timeout
45026     EHI: timeout waiting for A/D output
45027     EHI: LV LCA not initialized
45028     EHI: LV LCA not done
45029     EHI: LV serial communications RX timeout
45030     EHI: LV board not connected
45031     EHI: incorrect light level at start of edge detection - check if plate loaded is too large
45032     EHI: Unable to balance stroke to better than head bpmaxerr percent
45033     EHI: library call failed
45034     EHI: the thermal head requires an upgrade
45035     EHI: case temperature high alarm, <Case temperature> C
45036     EHI: case temperature high warning, <Case temperature> C
45037     EHI: case temperature low alarm, <Case temperature> C
45038     EHI: case temperature low warning, <Case temperature> C
45039     EHI: ambient temperature high alarm, <Ambient temperature> C
45040     EHI: ambient temperature high warning, <Ambient temperature> C
45041     EHI: case and ambient temperature normal
45042     EHI: shutdown of thermal head due to temperature or humidity alarm
45043     EHI: thermal head humidity alarm, <Humidity> percent
45044     EHI: unable to learn focus, change focus mode or shift plot
45045     EHI: unable to find exposure power, set to 0 W
45100     STA: Internal: bad parameter
45101     STA: Statistic identifier <Statistic identifier> was not registered
45102     STA: Statistic identifier <Statistic identifier> has already been registered
45103     STA: System resource unavailable
45104     STA: Invalid statistic type for attempted operation
45105     STA: Statistic data type description index out of range
45204     PRD: WARNING: The device is currently running in simulation mode - for testing purposes only!
45205     PRD: Invalid limit tag specified
45206     PRD: Option '<Option name>' could not be enabled because option '<Option name>' is already enabled, only one is allowed
45207     PRD: Option '<Option name>' could not be enabled because it is not allowed in this configuration
45213     PRD: Chiller flow is too low
45232     PRD: Safety override switch is on, cannot plot with override on
45234     PRD: Warning: System Pressure Low
45235     PRD: Safety loop is not enabled (<I/OName>)
45236     PRD: Head Input Fault: <Input bit description> (<Input bit name>) In Unexpected State
45238     PRD: Temperature conversion failed
45242     PRD: Chiller flow is too low (<bit description>)
45244     PRD: The safety override keyswitch is activated
45245     PRD: Option '<Option name>' could not be enabled because option '<Option name>' needs to be enabled first.
45247     PRD: License is invalid, product family is '<License Product Family>', it is required to be '<Product Family>'
45248     PRD: License is invalid, option '<Option>' needs to be <Require state>
45249     PRD: The write laser power is not being detected
45250     PRD: License is invalid, unrecognized speed designator '<License Speed Designator>'
45251     PRD: Option '<Option>' has changed due to licensing, device must be reset
45263     PRD: Component not available to set offline or online
45265     PRD: Media dropped while drum spinning
45283     PRD: <Board name> (<Board ID>) <Relay name> relay contacts welded, replace board
45400     _405: PPC 405 General Failure
45401     _405: reset induced by software watchdog
45700     GMCEX: Bad Memory Address specified in monitor command
45701     GMCEX: GMCE board memory erase failure has occured
45702     GMCEX: Failure reading eeprom or flash memory
45703     GMCEX: Failure writing to eeprom or flash memory
45704     GMCEX: An Un-Supported CPU Interrupt has occured.
45705     GMCEX: RCON File Burn Status Query With Invalid File ID
45706     GMCEX: Invalid format type
45707     GMCEX: Invalid engineering units
45708     GMCEX: Failure creating or configuring TCP/IP socket
45709     GMCEX: Invalid IP address received for TH3 head
45710     GMCEX: A calculated file checksum is invlaid
46201     FWD: Empty firmware directory sector
46202     FWD: FWD Entry Not Found
46203     FWD: FWD handle is invalid
46204     FWD: FWD entry table integrity error
46205     FWD: Component ID is invalid
46206     FWD: Invalid function parameter
46207     FWD: Firmware directory entry table is full
46208     FWD: Invalid firmware directory entry or component check sum
46209     FWD: Directory table synchronization failure
46210     FWD: Directory table contains duplicated entries
46211     FWD: Directory table need to be validated
46212     FWD: End of directory table reached
46213     FWD: Firmware directory system is locked
46214     FWD: Failed to lock firmware directory system
46501     CFS: Invalid Path
46502     CFS: No More File/Dir Entry In Subdirectory
46503     CFS: API Function Not Supported
46504     CFS: File or Directory Already Exist
46505     CFS: File Or Directory Not Found
46506     CFS: Path Not Found
46507     CFS: Invalid File Attribute
46508     CFS: Invalid Handle
46509     CFS: Invalid Directory Tree
46510     CFS: File or Subdirectory Deletion Is Not Allowed
46511     CFS: No More Directory_Entry Is Available
46512     CFS: End Of File Reached
46513     CFS: File Write Is Not Allowed
46514     CFS: Media Is Full
46515     CFS: File Allocation Table Integrity Error
46516     CFS: Subdirectory Can Not Be Deleted
46517     CFS: Exclusive File Open Failure
46518     CFS: File/Dir Rename Failure
46519     CFS: Firmware Binary File Deletion Refused
46701     HIM: A parameter to an internal function is invalid
46702     HIM: Attempt to register too many notification callbacks
46703     HIM: Attempt to clear callback that was not previously established
46704     HIM: Head command currently in progress has been preempted
46705     HIM: The head programming operation could not be started
46706     HIM: Head programming state machine integrity violated
46707     HIM: File download state machine integrity violated
46708     HIM: No response from the head while downloading bootloader
46709     HIM: Protocol violation while downloading bootloader to the head
46710     HIM: Head does not support this version of bootloader
46711     HIM: No response from the head while programming
46712     HIM: Protocol violation while programming the head
46713     HIM: Head bootloader failed to program
46714     HIM: Serial port overflow while programming the head
46715     HIM: No data received from the workstation while programming the head
46716     HIM: 'S' expected (received <Received character>) at start of record <Line number> in S-record file
46717     HIM: Invalid record type found at record <Line number> in S-record file
46718     HIM: Invalid data byte <Invalid byte> found at offset <Record offset> of record <Line number> in S-record file
46719     HIM: Checksum failed on record <Line number> in S-record file
46720     HIM: Extra character(s) found at end of record <Line number> in S-record file
46721     HIM: Multiple head interface failures - check interface cable
46722     HIM: No head detected on fiber link - check cable and BOOTP server
46723     HIM: No head detected on serial link - check cable
46724     HIM: Thermal head FTP download file has an invalid checksum
46725     HIM: Thermal head FTP download file name is invalid
46801     CFL: Not connected to the Feature Licensing Server
46802     CFL: XML Parser Overflow
46803     CFL: XML Unknown escape sequence
46804     CFL: Illegal character in XML message
46806     CFL: Invalid State in XML parser
46807     CFL: Malformed XML message detected
46808     CFL: XML Parser memory allocation failure
46809     CFL: XML Parser does not support more than 8 bit characters
46810     CFL: Feature Licensing detected encryption memory corruption
46811     CFL: Feature Licensing detected a failure with a socket operation
46812     CFL: Communication timeout with the Feature Licensing Server
46813     CFL: XML Node Not found
46814     CFL: Feature licensing authentication failure
46815     CFL: Feature Licensing integrity check failed
46816     CFL: Licensing feature is not supported
46817     CFL: Feature value for "<Limit Name - This is the name of the feature value that is being verified>" (<Limit ID - The numeric representation (Limit Tag value>) is outside of it's licensed range
46818     CFL: Feature Licensing subsystem is not initialized
46819     CFL: Invalid limit tag <Tag - The parameter is the numeric value of the internally used limit tag> used.
46820     CFL: No more Feature Licensing connections available
46821     CFL: Invalid Feature Licensing connection ID
46822     CFL: Feature Licensing connection has been disconnected
46823     CFL: Feature Licensing connection failed
46824     CFL: Feature Licensing Server had an internal error
46825     CFL: Feature Licensing Server communication failed
46826     CFL: Feature Licensing Server cannot detect a service dongle
46827     CFL: Feature Licensing Server was requested information about a invalid service component
46828     CFL: Feature Licensing Server cannot find the appropriate license
46829     CFL: Feature Licensing Server cannot detect a customer dongle
46830     CFL: Invalid IP address used when communicating with the Feature Licensing Server
46831     CFL: Feature Licensing Server detects an invalid customer dongle
46832     CFL: Feature Licensing Server does not support this version of firmware
46833     CFL: Feature Licensing Server could not find requested feature
46834     CFL: Feature Licensing Server could not find requested tag
46835     CFL: Feature Licensing Server could not find requested value
46901     DCC: Just a placeholder error
47807     MDH: <motor name> stepper motor did not reach or remain on the sensor it was searching for [<I/O name>]
47904     MDH: Slip sheet bin is full, empty slip sheet bin