proofing
- Workflow templates don't automatically output imposed proofs
- Prinergy stops responding when importing Prinergy Evo or Kodak Proofing Software custom color libraries
- Artifacts appear on low-resolution contone TIFFs when using antialiasing (Prinergy 3.1.0.8 and earlier)
- Characters filled in on high-resolution Prinergy output or at high magnification in Acrobat
- Output Process Template dynamic parameters fail to populate, if pointing to a Pool and Printer JTPs are on different servers.
- Veris output fails with media not found error but for a different output device
- Prinergy 3.1 variable marks are not populated correctly on output proofs or plates
- How to make Nahanni Proxy (PrinterJTP) stop finding Veris proofers and suppress all its messages in diag
- Can't see Kodak Veris, Kodak Matchprint, or Kodak Proofing Software proofer in process template [ID: 82134]
- DCS Raster to the Kodak Approval with Harlequin front end does not work properly
- Distorted output from Prinergy to AgfaJet Sherpa 2i
- Printer JTPs won't start on the EPM server when in EPM mode
- How to colormatch a separated file with spots for proofing on a contone proofer
- Print Console JTP crashes continuously
- Copydot proofs look bad when going to a contone ink jet proofer
- Unwanted background tint when using Raster CM (Overprint Handling)
- ICC profile not applied when using new Printer JTP and Overprint Handling in 2.2.1.9 and earlier
- Devicelink ICC profile not applied if Proof Process Profile is missing.
- When switching between Veris servers, edit the Device tab first in the process plan
- Prinergy reports an internal error when processing a certified proof on Veris
- DCS-2 files with TIFF preview fails in Kodak Approval
- Veris certified output fails when using the HDAG CM and a device link final output profile in 2.2.1.5
- Difference between HDAG and Creo CM when mapping spots on output.
- Photoshop-compatible Prinergy DCS-2 files do not work on Kodak Approval
- DCS images containing CMYK 0,0,0,0 create "scum dot" on final output, when scaled.
- Color Mapping Spots to Process in Loose Page Output Dialogue under "Apply Color Output Changes" produces wrong output.
- Duplexing options not available in new process plan for Imposition Proof
- Can't print DeviceN pages directly from Adobe Acrobat to a proofer.
- Color Combiner produces different results than Color Matcher when converting spot colors to process
- Color match fails on imposed output when one page position is empty
- Prinergy DCS files crash Kodak Approval XP4 AIT software
- How do I change the color of Trim and Bleed lines (marks) on proofs?
- Can't print DeviceN pages directly from Adobe Acrobat to a proofer.
- Improving spot color simulation using color combiner for RGB and Grayscale output
- Output fails when device path is set to %JOB%
- JTP starts on secondaries or renderstation but it does not process any jobs
- When trying to print different sized pages from a multi-tray printer, printer keeps defaulting to one tray
- Prinergy refuses to render to a third-party proofing device via NT Print Queue
- TIFF colorized white in Quark disappears on output
- Output to proof fails with "Failed to initialize printer" error
- All JTPs shut down when using CT/LW Output or Veris connectivity process plans
- DCS images containing CMYK 0,0,0,0 create scum dot on final output, when scaled.
- Page mark representing the CAD lines in a layout proof is not positioned correctly
- Proof from Prinergy comes out muddy looking, or colors look wrong
- How do I cancel a proof after it has already been sent to the proofer?
- Staccato screen is used for spot colors even when color combiner is turned off
- When outlining or trapping fonts, text appears fatter at low resolution
- Heidelberg Licensed Screens for proofing does not work in 2.1.0.8
- Proofing fails when colormatch JTP and RIP is not on the server
- Ability to disable color-matcher..
- Proofing tasks fail with the error "The subtask list is incomplete"
- HP DesignJet proofer stops printing in the middle of a Prinergy job
- Multi-page PDF vector output fails on very large or complicated jobs
- Artifacts on HP 5000 output sent from Prinergy 2.0.7 or CPS
- DeviceN image does not appear on output page
- Prinergy proofing images have wedges of detail missing on contone (256 shades) output
- Contone DCS output causes PostScript errors
- Unable to create a PS3 JTP or PS3 JTP will not start after Minor Update 2.0.5.4 is applied
- Spot colors on proof are not correct
- Text has extra spaces in imposed proof and final output, but not in loose page proof
- Iris43Wide 2-sided imposition proof is mismatched between the front-side and back-side
- Some elements are lost when doing a composite proof
- How do I do duplexing in Prinergy 1.1?
- Proof doesn't match plate when Colormatch JTP is enabled for proof only
- Customer wants to do remote proofing using WAM!PROOF
- The "Layout is 90 deg different than Media" check box is greyed out in existing Loose Page Proof process plans
- Customer wants to use the Dupont Color Station RIP
- Epson printer stops printing in middle of proof
- Is my proof output screened?
- Process daemon (PTaskD) crashes when doing proofs from Page Set window
- Proofing JTPs are hanging
- When using color combiner, the image quality is poor
- How to use loose page proofs in Scatterproofing
- Harlequin RIP rejects DCS or EPS from Prinergy
- Prinergy Proofing: When RIPing a DCS to Polaproof, RIP times are suspiciously slow
- Can't get the Barco Impress to print on the first eight inches of media
- Back-ups are out of registration on the Barco Impress
- Output on composite proofer (Hewlett-Packard) is only one color
- Loose page proofs takes a long time to RIP when a large amount of files are submitted at once
- Using Digital Blueline to Make 2-Up, Duplexed Proofs
- Don't get full bleed (or any bleed) on some proofs
- On imposed proof or final output, marks are rotated 90 degrees
- Varnish doesn't seem to appear on proof
- Digital Blueline fails when used with Prinergy VPS output
- In page proofs, application trim and crop marks appear outside final trim and bleed area
- Loose page proofs to HP5Si failed
- Output from Kodak Approval proofer looks wavy
- How do I use Digital Blueline with Prinergy VPS files?
- Image is being clipped on an 8-up Spectrum proof
- On CEPSLink pages, text looks thin in some places and thicker in others
- Upon completion of a proof, annoying message box appears on the server
- Proofing process fails to complete